Multi-Function Thermal Conductivity Measurement Platform
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Multi-Function Thermal Conductivity Measurement Platform is an absolute-method measurement system designed for accurate determination of thermal conductivity, thermal diffusivity, specific heat capacity, and thermal effusivity of solids, liquids, pastes, and powders. By integrating multiple transient techniques on a single platform, the system enables direct calculation of thermal properties from raw data without calibration materials, supporting reliable and repeatable measurements across a wide range of material types.
Application
The Multi-Function Thermal Conductivity Measurement Platform is suitable for thermal property evaluation in research, quality control, and material development, including:
Polymers, composites, and building materials
Liquids and phase-change materials
Pastes, powders, and bulk solids
Soil and polymeric materials
Typical test samples include solid blocks and plates, liquid samples, powders, pastes, and soil specimens, depending on the selected sensor and test method.
Standards
The platform supports internationally recognized absolute measurement standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
Parameters
| Method | TPS | THW | MTPS | TLS |
|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Soil, pastes, polymers |
| Measurement Module | 3D bulk, anisotropic, plate, thin film; general: specific heat | Bulk | 3D bulk, anisotropic, plate; 1D standard | Bulk |
| Thermal Conductivity (W/m·K) | 0.01–500 | 0.01–2 | 0.03–500 | 0.1–8 |
| Thermal Diffusivity (mm²/s) | 0.01–300 | Up to 0.5 | 0.01–300 | Not applicable |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Not applicable |
| Thermal Effusivity (W·s½/m²·K) | 20–40000 | Not applicable | 20–40000 | Not applicable |
| Sample Size (mm | mL) | Ø10 or square | 20 mL | Ø25 or square |
| Sample Thickness (mm) | ≥0.05 | Not applicable | ≥0.1 | Probe length 100 |
| Maximum Sample Size | Unlimited | Unlimited | Unlimited | Unlimited |
| Test Time (s) | 2–160 | 1 | 2–160 | 180 |
| Accuracy (Thermal Conductivity) | 5% | 2% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 2% | 1% | 2% | 2% |
| Temperature Range (°C) | 0–300 / −75–300 | −50–200 | 0–100 / −50–200 | −40–100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Insert type |
| Supported Standards | ISO 22007-2. ISO 22007-7. GB/T 32064. ASTM E3088 | ASTM D7896 | ISO 22007-7 | ASTM D5334. ASTM D5930 |
Features
Absolute measurement methods with no calibration materials required
Multiple transient techniques integrated on a single platform
Direct measurement of thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil
Raw data–based calculation improves traceability and measurement reliability
在线联系供应商
Other supplier products
| Large capacity walk-in stability test chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Pharmaceutical Stability Testing Laboratory is designed for conducting accele... | |
| Anti-glare Panel Falling Weight Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The falling weight impact testing machine is suitable for determining the external impact r... | |
| Paper roughness tester for quality control | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Paper Roughness and Air Permeability Tester (TMI) simultaneously measures the... | |
| Electrical Wire Halogen Gas Emission Test Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This apparatus is widely used in laboratories and quality control departments ... | |
| High Velocity Impact Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purpose To test the impact - resistance performance of glasses, goggles and face shie... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |













