16-Segment Heated Thermal Manikin (Dry Type)

Application

The 16-Segment Heated Thermal Manikin is used in the following application areas:

(1) Cleanroom airflow evaluation and contamination risk assessment

(2) HVAC research, teaching, and indoor thermal comfort studies

(3) Thermal insulation testing of workwear, protective clothing, and medical garments

(4) Simulation of human heat sources in vehicle interiors, buses, trains, ships, and submarines

(5) Aircraft, spacecraft, and cabin thermal environment studies

(6) Hospital operating room temperature control and patient thermal protection testing

(7) Occupational safety and thermal stress evaluation in controlled environments

Standards

The system is designed and manufactured with reference to the following international and national standards:

(1) ISO 14644-1 / ISO 14644-3 – Cleanrooms and associated controlled environments

(2) DIN 1946-4 – Ventilation and air-conditioning systems in healthcare facilities

(3) ISO 14505-2 – Determination of thermal insulation using a thermal manikin (analogous method)

(4) ASTM F1291 – Thermal insulation of clothing using a heated manikin

(5) EN 14058 – Protective clothing against cool environments (reference testing)

(6) GB/T 18883-2020 – Indoor air quality standard

(7) GB/T 50785-2012 – Cleanroom design and testing for hospitals

(8) GB 50333-2013 – Technical code for hospital HVAC system design

(9) GB/T 4249-2019 – Indoor thermal environment impact on human body

(10) YY/T 0287-2009 – Thermal performance evaluation of medical protective clothing

Parameters

ComponentTechnical Parameter
Manikin body 16 independent heating zones (head, torso, arms, legs); glass fiber reinforced resin; standing or sitting posture; customizable Asian or European body shape
Heating system Nickel-chromium heating wires; PT100 B-class sensors; surface temperature 32–37°C (33 ± 0.5°C typical); center temperature 37 ± 0.1°C
Zone uniformity Maximum temperature difference between zones ≤ 1.0°C
Control system 16-segment PID temperature control; 2 × 8-channel boards; automatic PID tuning
Control box 780 × 780 × 260 mm; mobile base with brakes; aircraft-style quick connectors
Heat output 70–100 W per manikin, adjustable
Surface material Smooth, non-particle shedding, suitable for cleanroom use
Operating environment Temperature 10–40°C; humidity 15–95% RH
Power supply AC 220–240 V, 50 Hz
Power consumption Peak ≤ 1200 W; steady-state heat flux 0–300 W/m²
Manikin height Approx. 180 cm (standing posture)
Manikin weight Approx. 45 kg
Optional customization Child or infant manikins; individual body parts; lying posture patient simulation

Features

(1) Sixteen independent heating zones for stable and uniform heat distribution

(2) Dry-type design without sweating or breathing for simplified operation and cost efficiency

(3) High-precision temperature control using dedicated PID regulation

(4) Adjustable surface and core temperature for various thermal simulation scenarios

(5) Flexible posture options including standing, sitting, or lying configurations

(6) Cleanroom-compatible surface with low particle emission

(7) Quick-connect cabling and mobile control unit for convenient installation

(8) Compatibility with expanded GB/T and YY/T standards for medical and HVAC testing


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Multiphase High - temperature and High - pressure Explosion Limit Tester
Multiphase High - temperature and High - pressure Explosion Limit Tester The Multiphase High-Temperature and High-Pressure Explosion Limit Tester is an instrument developed based on standards such as EN 1839, ASTM E918, ...
Spectrophotometer
Spectrophotometer Standard CIE No.15. ISO 7724-1: Meets international colorimetry and spectral measurement standards. ASTM E1164. DIN 5033: Compliant with industri...
Rubber Low-Temperature Brittleness Evaluation Machine
Rubber Low-Temperature Brittleness Evaluation Machine Product Introduction: Plastic low temperature embrittlement testing machine is to determine the temperature of rubber and plastic when the sample ...
Femoral Stem Neck Prostheses Fatigue Tester
Femoral Stem Neck Prostheses Fatigue Tester Standard YY/T 0809.6 (China): Specifies neck fatigue testing for femoral stems in partial/total hip arthroplasty. ISO 7206-6 (International): Def...
Incline Impact Tester
Incline Impact Tester The Incline Impact Tester is designed to evaluate the impact resistance of products, packaging, and transport systems under controlled oblique load...
供应产品

Same products

Common Rail Control Valve Assembly F00ZC01307
Common Rail Control Valve Assembly F00ZC01307 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ...
Fuel Injector Control Valve Set F00RJ01479
Fuel Injector Control Valve Set F00RJ01479 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto...
Fuel Injector Valve Set F00RJ02213
Fuel Injector Valve Set F00RJ02213 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto...
Common Rail Injector Valve Set F00RJ00339
Common Rail Injector Valve Set F00RJ00339 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ...
Fuel Injection Pump  for Yanmar Wb93r Wb97r Wb97s Wb98a
Fuel Injection Pump for Yanmar Wb93r Wb97r Wb97s Wb98a 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecti...