16-Segment Heated Thermal Manikin (Dry Type)
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The 16-Segment Heated Thermal Manikin is used in the following application areas:
(1) Cleanroom airflow evaluation and contamination risk assessment
(2) HVAC research, teaching, and indoor thermal comfort studies
(3) Thermal insulation testing of workwear, protective clothing, and medical garments
(4) Simulation of human heat sources in vehicle interiors, buses, trains, ships, and submarines
(5) Aircraft, spacecraft, and cabin thermal environment studies
(6) Hospital operating room temperature control and patient thermal protection testing
(7) Occupational safety and thermal stress evaluation in controlled environments
Standards
The system is designed and manufactured with reference to the following international and national standards:
(1) ISO 14644-1 / ISO 14644-3 – Cleanrooms and associated controlled environments
(2) DIN 1946-4 – Ventilation and air-conditioning systems in healthcare facilities
(3) ISO 14505-2 – Determination of thermal insulation using a thermal manikin (analogous method)
(4) ASTM F1291 – Thermal insulation of clothing using a heated manikin
(5) EN 14058 – Protective clothing against cool environments (reference testing)
(6) GB/T 18883-2020 – Indoor air quality standard
(7) GB/T 50785-2012 – Cleanroom design and testing for hospitals
(8) GB 50333-2013 – Technical code for hospital HVAC system design
(9) GB/T 4249-2019 – Indoor thermal environment impact on human body
(10) YY/T 0287-2009 – Thermal performance evaluation of medical protective clothing
Parameters
| Component | Technical Parameter |
|---|---|
| Manikin body | 16 independent heating zones (head, torso, arms, legs); glass fiber reinforced resin; standing or sitting posture; customizable Asian or European body shape |
| Heating system | Nickel-chromium heating wires; PT100 B-class sensors; surface temperature 32–37°C (33 ± 0.5°C typical); center temperature 37 ± 0.1°C |
| Zone uniformity | Maximum temperature difference between zones ≤ 1.0°C |
| Control system | 16-segment PID temperature control; 2 × 8-channel boards; automatic PID tuning |
| Control box | 780 × 780 × 260 mm; mobile base with brakes; aircraft-style quick connectors |
| Heat output | 70–100 W per manikin, adjustable |
| Surface material | Smooth, non-particle shedding, suitable for cleanroom use |
| Operating environment | Temperature 10–40°C; humidity 15–95% RH |
| Power supply | AC 220–240 V, 50 Hz |
| Power consumption | Peak ≤ 1200 W; steady-state heat flux 0–300 W/m² |
| Manikin height | Approx. 180 cm (standing posture) |
| Manikin weight | Approx. 45 kg |
| Optional customization | Child or infant manikins; individual body parts; lying posture patient simulation |
Features
(1) Sixteen independent heating zones for stable and uniform heat distribution
(2) Dry-type design without sweating or breathing for simplified operation and cost efficiency
(3) High-precision temperature control using dedicated PID regulation
(4) Adjustable surface and core temperature for various thermal simulation scenarios
(5) Flexible posture options including standing, sitting, or lying configurations
(6) Cleanroom-compatible surface with low particle emission
(7) Quick-connect cabling and mobile control unit for convenient installation
(8) Compatibility with expanded GB/T and YY/T standards for medical and HVAC testing
在线联系供应商
Other supplier products
| Bone Plates Four-point Bending Fatigue Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 1503-2016: Chinese standard specifying test methods for bending fatigu... | |
| IEC 60331 Cable Fire Resistance Test Equipment Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Technical Specifications ItemTechnical ... | |
| ISO Certified Robotic Vacuum Navigation Test System Factory | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GBT 40229-2021 – Testing Method for Robotic Vacuum Cleaner E... | |
| Thrust Bearing Rolling Friction and Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable Standards: ASTM D3702 ASTM G99 ASTM G77 ISO 18535 Product Advantages: Simu... | |
| UV Xenon Arc Weather Testing Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product introduction This equipment uses xenon arc lamp that can simulate the whole spectr... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |