16-Segment Heated Thermal Manikin (Dry Type)
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The 16-Segment Heated Thermal Manikin is used in the following application areas:
(1) Cleanroom airflow evaluation and contamination risk assessment
(2) HVAC research, teaching, and indoor thermal comfort studies
(3) Thermal insulation testing of workwear, protective clothing, and medical garments
(4) Simulation of human heat sources in vehicle interiors, buses, trains, ships, and submarines
(5) Aircraft, spacecraft, and cabin thermal environment studies
(6) Hospital operating room temperature control and patient thermal protection testing
(7) Occupational safety and thermal stress evaluation in controlled environments
Standards
The system is designed and manufactured with reference to the following international and national standards:
(1) ISO 14644-1 / ISO 14644-3 – Cleanrooms and associated controlled environments
(2) DIN 1946-4 – Ventilation and air-conditioning systems in healthcare facilities
(3) ISO 14505-2 – Determination of thermal insulation using a thermal manikin (analogous method)
(4) ASTM F1291 – Thermal insulation of clothing using a heated manikin
(5) EN 14058 – Protective clothing against cool environments (reference testing)
(6) GB/T 18883-2020 – Indoor air quality standard
(7) GB/T 50785-2012 – Cleanroom design and testing for hospitals
(8) GB 50333-2013 – Technical code for hospital HVAC system design
(9) GB/T 4249-2019 – Indoor thermal environment impact on human body
(10) YY/T 0287-2009 – Thermal performance evaluation of medical protective clothing
Parameters
| Component | Technical Parameter |
|---|---|
| Manikin body | 16 independent heating zones (head, torso, arms, legs); glass fiber reinforced resin; standing or sitting posture; customizable Asian or European body shape |
| Heating system | Nickel-chromium heating wires; PT100 B-class sensors; surface temperature 32–37°C (33 ± 0.5°C typical); center temperature 37 ± 0.1°C |
| Zone uniformity | Maximum temperature difference between zones ≤ 1.0°C |
| Control system | 16-segment PID temperature control; 2 × 8-channel boards; automatic PID tuning |
| Control box | 780 × 780 × 260 mm; mobile base with brakes; aircraft-style quick connectors |
| Heat output | 70–100 W per manikin, adjustable |
| Surface material | Smooth, non-particle shedding, suitable for cleanroom use |
| Operating environment | Temperature 10–40°C; humidity 15–95% RH |
| Power supply | AC 220–240 V, 50 Hz |
| Power consumption | Peak ≤ 1200 W; steady-state heat flux 0–300 W/m² |
| Manikin height | Approx. 180 cm (standing posture) |
| Manikin weight | Approx. 45 kg |
| Optional customization | Child or infant manikins; individual body parts; lying posture patient simulation |
Features
(1) Sixteen independent heating zones for stable and uniform heat distribution
(2) Dry-type design without sweating or breathing for simplified operation and cost efficiency
(3) High-precision temperature control using dedicated PID regulation
(4) Adjustable surface and core temperature for various thermal simulation scenarios
(5) Flexible posture options including standing, sitting, or lying configurations
(6) Cleanroom-compatible surface with low particle emission
(7) Quick-connect cabling and mobile control unit for convenient installation
(8) Compatibility with expanded GB/T and YY/T standards for medical and HVAC testing
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Catheter Residual Vacuum Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Residual Vacuum Tester is a professional device used to detect the residual va... | |
| BS EN ISO 6529 Chemical permeation resistance tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application You use this tester to measure the chemical liquid penetration resistance of p... | |
| Abrasive Wear Test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM G65 - 04 GB/T 3960-1983 Main Purposes The wet - type rubber wheel abrasiv... | |
| Suture Needle Cutting Force Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Suture Needle Cutting Force Tester is a precision instrument specifically used to detec... | |
| Safety Helmet Impact and Penetration Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Safety Helmet Acceleration Impact and Penetration Tester is a specialized testing machi... |
Похожие товары
| Laser Cutting Machines | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ... | |
| Precision Laser Micromachining Machine | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ... | |
| Ultrafast Laser Systems | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi... | |
| Industrial Laser Equipment Manufacturer | Продавец: Chanxan (Changshu) Laser Technology Co., Ltd. | Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan... | |
| Common Rail Injector Valve F00R J02 012 | Продавец: 868983 | Common Rail Injector Valve F00R J02 012 David Chen |