16-Segment Heated Thermal Manikin (Dry Type)
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The 16-Segment Heated Thermal Manikin is used in the following application areas:
(1) Cleanroom airflow evaluation and contamination risk assessment
(2) HVAC research, teaching, and indoor thermal comfort studies
(3) Thermal insulation testing of workwear, protective clothing, and medical garments
(4) Simulation of human heat sources in vehicle interiors, buses, trains, ships, and submarines
(5) Aircraft, spacecraft, and cabin thermal environment studies
(6) Hospital operating room temperature control and patient thermal protection testing
(7) Occupational safety and thermal stress evaluation in controlled environments
Standards
The system is designed and manufactured with reference to the following international and national standards:
(1) ISO 14644-1 / ISO 14644-3 – Cleanrooms and associated controlled environments
(2) DIN 1946-4 – Ventilation and air-conditioning systems in healthcare facilities
(3) ISO 14505-2 – Determination of thermal insulation using a thermal manikin (analogous method)
(4) ASTM F1291 – Thermal insulation of clothing using a heated manikin
(5) EN 14058 – Protective clothing against cool environments (reference testing)
(6) GB/T 18883-2020 – Indoor air quality standard
(7) GB/T 50785-2012 – Cleanroom design and testing for hospitals
(8) GB 50333-2013 – Technical code for hospital HVAC system design
(9) GB/T 4249-2019 – Indoor thermal environment impact on human body
(10) YY/T 0287-2009 – Thermal performance evaluation of medical protective clothing
Parameters
| Component | Technical Parameter |
|---|---|
| Manikin body | 16 independent heating zones (head, torso, arms, legs); glass fiber reinforced resin; standing or sitting posture; customizable Asian or European body shape |
| Heating system | Nickel-chromium heating wires; PT100 B-class sensors; surface temperature 32–37°C (33 ± 0.5°C typical); center temperature 37 ± 0.1°C |
| Zone uniformity | Maximum temperature difference between zones ≤ 1.0°C |
| Control system | 16-segment PID temperature control; 2 × 8-channel boards; automatic PID tuning |
| Control box | 780 × 780 × 260 mm; mobile base with brakes; aircraft-style quick connectors |
| Heat output | 70–100 W per manikin, adjustable |
| Surface material | Smooth, non-particle shedding, suitable for cleanroom use |
| Operating environment | Temperature 10–40°C; humidity 15–95% RH |
| Power supply | AC 220–240 V, 50 Hz |
| Power consumption | Peak ≤ 1200 W; steady-state heat flux 0–300 W/m² |
| Manikin height | Approx. 180 cm (standing posture) |
| Manikin weight | Approx. 45 kg |
| Optional customization | Child or infant manikins; individual body parts; lying posture patient simulation |
Features
(1) Sixteen independent heating zones for stable and uniform heat distribution
(2) Dry-type design without sweating or breathing for simplified operation and cost efficiency
(3) High-precision temperature control using dedicated PID regulation
(4) Adjustable surface and core temperature for various thermal simulation scenarios
(5) Flexible posture options including standing, sitting, or lying configurations
(6) Cleanroom-compatible surface with low particle emission
(7) Quick-connect cabling and mobile control unit for convenient installation
(8) Compatibility with expanded GB/T and YY/T standards for medical and HVAC testing
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| High Temperature Half Mannequin | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The High-Temperature Half Mannequin is suitable for testing a variety of prote... | |
| Automotive Wire Insulation Manual Bend Test System Factory Direct | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Parameters ParameterSpecification Clamp Type Manual Clamp S... | |
| Color Stability Tester for Dental Materials | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Dentistry Base Polymer Search Stability tester evaluates color stability ... | |
| ASTM D635 Paper Flammability Tester Manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters DescriptionDetails Am... | |
| Automated infusion pump tester equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB 8368 - 2018 : Disposable Infusion Sets Features 1. Industrial-grade capacit... |
Похожие товары
| PanEVAP & MVR system | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... | |
| PanPHE gasketed plate heat exchangers | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ... |