Auto calibrating catheter flow meter
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
The catheter flow tester is mainly used to measure and evaluate the flow performance of medical catheters, such as intravascular catheters, non - intravascular catheters, and infusion set catheters. In the medical field, this tester has a wide range of applications, including but not limited to the following aspects: Product R & D: During the design and R & D stage of catheter products, the tester can help engineers accurately assess the flow performance of different design schemes, providing powerful data support for product iteration. Quality Control: Through batch testing, the tester can ensure that each batch of catheters meets the established flow standards and performance requirements, thus improving the overall quality of products. Clinical Application: The tester can be used to monitor the flow changes of catheters in patients, providing real - time physiological parameter feedback to doctors, which is helpful for adjusting treatment plans, assessing the progress of the disease, and preventing complications.
Standards
GB/T 15812.1 - 2005 Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods
YY 0285.1 - 2017 Disposable Sterile Intravascular Catheters
Technical Parameters
| Parameter | Specification |
|---|---|
| Testing Range | Usually within a weight/volume range (e.g., 1.00 - 600.00g, varying by catheter specifications) or a specific flow range |
| Accuracy | High testing accuracy (e.g., ±0.01%FS, one-ten-thousandth of full scale) or higher requirements |
| Static Water Level Height | e.g., 200±5mm, 1000±5mm (meets different testing needs); water pump has automatic circulation function; static water level is adjustable |
| Time Controller | Usually 0 - 60min, with an error ≤ ±1S; used to control testing time |
| Fixtures | Adapt to various catheter specifications/types, ensuring test versatility and flexibility |
| Flow Calculation | Generally uses the weighing method (imported flowmeters optional) to calculate flow, ensuring result accuracy |
| Flow Rate | e.g., 525ml/min (arbitrary selection) ±25ml/min, etc.; adapts to different testing scenarios |
| Intelligent Temperature Control | Equipped with a micro-computer intelligent temperature-control system, ensuring constancy and accuracy of test temperature |
| Special Accessories | Includes stainless-steel thermostatic water baths, special connectors, etc.; meets testing needs of different catheter specifications/types |
Accessoriess
Static pressure head, height adjustment device, constant temperature water bath, PU tubing
Test Procedures
1. Before testing, appropriate test conditions, such as water flow rate and pressure, should be set according to the pipe specifications and testing requirements. This helps to ensure the accuracy and reliability of the measurement results.
2. When connecting the pipes, ensure a tight, leak-free connection. Any leaks will affect the accuracy of the measurement results.
3. During the testing process, keep the testing instrument and pipes clean to avoid contamination affecting the test results. Regularly clean and maintain the instrument to ensure its proper functioning and extend its service life.
4. After the test is completed, turn off the testing instrument, disconnect the pipes, and clean and dry them for future use. This helps prevent corrosion and damage to the instrument and pipes due to prolonged disuse.
在线联系供应商
Other supplier products
| HEPA/ULPA filter scanning test bench | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) HEPA and ULPA Filter Classification: Determine filter grade and performanc... | |
| Photovoltaic module wire tube bending testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard IEC 61730-2:2004: Photovoltaic (PV) Module Safety Qualification – Requireme... | |
| PV Hail Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard Compliance IEC 61215: Mechanical load testing for terrestrial photovoltaic module... | |
| Probe-Type Material Surface Wear Scar Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Probe-Type Material Surface Wear Scar Tester is a precision device designed for high-ac... | |
| SI80 Carbon Arc Aging Tester丨SI80 Carbon Arc Aging Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Material aging and fading performance test SI80 carbon arc aging tester, carbon arc aging ... |
Same products
| ER4047 Aluminum Mig Welding Wire | 卖方: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing reliable welding material... | |
| ER4043 Silicon Aluminum Welding Wire | 卖方: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing high-quality welding mate... | |
| Choosing the Right Equipment for Heavy-Duty Cleaning | 卖方: Taizhou Feike Mechanical Technology Co., Ltd. | FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve... | |
| ER4043 Silicon Aluminum Welding Wire | 卖方: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin... | |
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... |













