Automated thermal constants measurement system
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The Multi-Function Thermal Constants Analyzer is used for quantitative thermal property evaluation in various material forms and industries, including:
Polymers, composites, and construction materials
Liquids, phase-change materials, and coolants
Pastes, powders, and bulk solids
Soil, polymers, and anisotropic materials
Typical test samples include solid plates, bulk materials, liquids in containers, pastes, powders, and soil samples, depending on the selected measurement method.
Standards
The analyzer supports multiple internationally recognized test methods and standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Standard test method for determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
(8) IEEE 442: Soil thermal resistivity measurement
Parameters
| Method | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Solid rectangular samples | Soil, pastes, polymers |
| Measurement Mode | 3D bulk, anisotropic, plate, thin film, 1D | Bulk | 3D bulk, anisotropic, plate, 1D | Bulk, anisotropic | Bulk |
| Thermal Conductivity (W/m·K) | 0.005–2000 | 0.01–2 | 0.03–500 | 0.01–2 | — |
| Thermal Diffusivity (mm²/s) | 0.01–1200 | Up to 0.5 | 0.01–300 | Up to 0.5 | — |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | — |
| Thermal Effusivity (W·s½/m²·K) | 5–60000 | Not applicable | 20–40000 | Not applicable | — |
| Contact Thermal Resistance (m²·K/W) | Measured | Not applicable | Measured | Not applicable | Not applicable |
| Sample Thickness (mm)* | ≥0.01 | — | ≥0.1 | — | — |
| Test Time (s) | 0.25–2560 | 1 | 0.25–2560 | 0.25–2560 | 180 |
| Accuracy (Thermal Conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature Range (°C)** | 0 to 300 / up to 750 or 1000 | 10 to 200 | 0 to 100 / −50 to 200 | −75 to 300 | −40 to 100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Symmetric / asymmetric | Insert type |
Accessories
(1) Transient plane heat source (TPS) sensors
(2) Transient hot-wire (THW) sensors
(3) Modified transient plane source (MTPS) sensors
(4) Transient hot strip (THS) sensors
(5) Transient line source (TLS) probes
(6) Sample holders for solid, liquid, and soil configurations
在线联系供应商
Other supplier products
| Keyboard Key Durability Testing Machine (for Keyboard Key Life Testing Machine) | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction Key life testing machine can be used to test the life of mobile s, MP... | |
| Automatic cleanliness tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The cleanliness analysis system fully complies with the requirements of standards such as V... | |
| Ink drying apparatus | Whats/App: +86 156 1874 6768 Web: standard-groups.com How it works: The working principle of the ink drying instrument is based on simulating th... | |
| Plastic Pipe Hydrostatic Pressure Burst meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 1167: For thermoplastics pipe systems under constant internal pressure. ASTM... | |
| Time-Pressure Oxidizing Liquid Analyzer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Conforms to UN Recommendations on the Transport of Dangerous Goods - M... |
Same products
| 卖方: 868983 | Common Rail Injector Valve F00R J01 334 Injector Valve Set F00V C01 361 Injector Valve Set F00V... | ||
| 卖方: 868983 | Common Rail Injector Valve F 00V C01 371 Injector Valve Set F00V C01 310 Injector Valve Set F00... | ||