Automotive coolant system flow and pulsation tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system supports compliance with major automotive industry standards:

TL 889 / TL 874 (4.4) – Volkswagen Group technical specification for cooling system materials and radiator functionality testing.

TL 52361 (6.1.1 / 6.1.2) – Volkswagen Group specification for coolant hoses (including aramid-reinforced) and functional performance (pressure pulsation and long-term static testing).

TL 52682 (6.11 / 6.12) – Volkswagen Group specification for glass-fiber reinforced PA66 used in cooling system components, including dynamic and static durability tests.

GMW15310 – General Motors global engineering standard for materials and component performance, including integrated vehicle/system testing.

GMW14322‑2016 (4.13) – GM global standard for environmental and durability testing with specific requirements.

GMW16288 – GM system-level durability and verification standard for cooling system components.

Parameters

Parameter CategoryDetails
Equipment Dimensions 4350 mm × 2520 mm × 2150 mm (W × H × D)
Environmental Chamber Dimensions 1800 × 1000 × 1000 mm (W × H × D)
Rated Power 60 kW
Test Medium Glycol/Water
Pressure Range 0…5 bar
Medium Flow Control Up to approx. 100 l/min
Linear Motion Parameters ±25 mm at 1 Hz
±12 mm at 5 Hz
±6 mm at 10 Hz
±2 mm at 20 Hz
Test Medium Temperature Range -40°C … +150°C
Environmental Temperature Control -40°C … +150°C
Test Channels 8

Features

Pressure pulsation testing machine with linear and eccentric motion device.

Pressure range from 0.1 up to max. 5 bar.

Heating of the environmental chamber through monitoring and limiting maximum surface temperature.

Automatic leak detection and leak testing with automatic shutdown of failed samples.

Automatic return pump to prevent coolant leakage.

Windows/LabVIEW-based control unit with integrated data acquisition and recording.

Accessories

Linear and eccentric motion drive unit

Environmental chamber with dual doors

Automatic leak detection sensors and safety shut-off

Coolant circulation and return pump

Windows/LabVIEW control system with data logging

Heating and temperature control modules

Test Procedures

Ensure installation space allows safe operation and access to all test channels.

Connect the system to the 60 kW power supply and ensure environmental temperature control is set.

Fill the system with glycol/water test medium.

Install the radiator, hose, or expansion tank in the test chamber.

Close front and rear doors to seal the chamber.

Set the desired pressure range, linear motion parameters, and temperature profiles in the control unit.

Start the test program via Windows/LabVIEW interface.

Monitor pressure, motion, temperature, and leak sensors throughout the test.

Automatically shut down any failed or leaking samples.

After testing, safely drain the test medium and allow the chamber to cool before removing samples.

Maintenance Information

Regularly inspect the motion drive, pressure sensors, and leak detection units for wear or damage.

Check glycol/water circulation system for blockages or leaks before each test.

Calibrate sensors and temperature controllers periodically to maintain measurement accuracy.

Clean environmental chamber surfaces and doors to prevent corrosion.

Replace worn seals, gaskets, or insulation as necessary to ensure safe operation.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Strength Tester for Lead - end of Photovoltaic Modules
Strength Tester for Lead - end of Photovoltaic Modules Whats/App: +86 156 1874 6768 Web: standard-groups.com The Strength Tester for Lead-End of Photovoltaic Modules is designed to evaluate the mechan...
ISO 5079 Single Fiber Strength Tester for Textile and Fiber Laboratories
ISO 5079 Single Fiber Strength Tester for Textile and Fiber Laboratories Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Microcomputer-controlled system with online communication capab...
Femoral Condyles Components Fatigue Performance Tester
Femoral Condyles Components Fatigue Performance Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM WK51649: Specifies fatigue testing protocols for metallic femoral components...
Computer-controlled Helmet Impact Tester
Computer-controlled Helmet Impact Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Scope This testing instrument is applicable to the impact - energy absorption ...
Acid corrosion resistance cabinet for toilets
Acid corrosion resistance cabinet for toilets Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Toilet seat hydrochloric acid and ammonia corrosion tester is used for testin...
供应产品

Same products

China factory electrode TGYS125 for power station Selection of advanced
China factory electrode TGYS125 for power station Selection of advanced 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory electrode TGYS125 for power station Selection of advanced technology, absolutely f...
Laser Chuck
Laser Chuck 卖方: 00000 Laser Chuck Introduce foreign advanced technology and management concept, High precision pro...
Power Pallet Jack For Sale
Power Pallet Jack For Sale 卖方: Jinan Hulk Machinery Co., Ltd Power Pallet Jack For Sale Electric Pallet Truck For Sale As a supplier of power pallet jac...
Multi Directional Forklift For Sale
Multi Directional Forklift For Sale 卖方: Jinan Hulk Machinery Co., Ltd Multi Directional Forklift For Sale Multi Directional Forklift For Sale As a supplier of mu...
Narrow Aisle Forklift For Sale
Narrow Aisle Forklift For Sale 卖方: Jinan Hulk Machinery Co., Ltd Narrow Aisle Forklift For Sale Narrow Aisle Forklift For Sale As a supplier of , we provide...