Automotive coolant system flow and pulsation tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system supports compliance with major automotive industry standards:
TL 889 / TL 874 (4.4) – Volkswagen Group technical specification for cooling system materials and radiator functionality testing.
TL 52361 (6.1.1 / 6.1.2) – Volkswagen Group specification for coolant hoses (including aramid-reinforced) and functional performance (pressure pulsation and long-term static testing).
TL 52682 (6.11 / 6.12) – Volkswagen Group specification for glass-fiber reinforced PA66 used in cooling system components, including dynamic and static durability tests.
GMW15310 – General Motors global engineering standard for materials and component performance, including integrated vehicle/system testing.
GMW14322‑2016 (4.13) – GM global standard for environmental and durability testing with specific requirements.
GMW16288 – GM system-level durability and verification standard for cooling system components.
Parameters
| Parameter Category | Details |
|---|---|
| Equipment Dimensions | 4350 mm × 2520 mm × 2150 mm (W × H × D) |
| Environmental Chamber Dimensions | 1800 × 1000 × 1000 mm (W × H × D) |
| Rated Power | 60 kW |
| Test Medium | Glycol/Water |
| Pressure Range | 0…5 bar |
| Medium Flow Control | Up to approx. 100 l/min |
| Linear Motion Parameters | ±25 mm at 1 Hz ±12 mm at 5 Hz ±6 mm at 10 Hz ±2 mm at 20 Hz |
| Test Medium Temperature Range | -40°C … +150°C |
| Environmental Temperature Control | -40°C … +150°C |
| Test Channels | 8 |
Features
Pressure pulsation testing machine with linear and eccentric motion device.
Pressure range from 0.1 up to max. 5 bar.
Heating of the environmental chamber through monitoring and limiting maximum surface temperature.
Automatic leak detection and leak testing with automatic shutdown of failed samples.
Automatic return pump to prevent coolant leakage.
Windows/LabVIEW-based control unit with integrated data acquisition and recording.
Accessories
Linear and eccentric motion drive unit
Environmental chamber with dual doors
Automatic leak detection sensors and safety shut-off
Coolant circulation and return pump
Windows/LabVIEW control system with data logging
Heating and temperature control modules
Test Procedures
Ensure installation space allows safe operation and access to all test channels.
Connect the system to the 60 kW power supply and ensure environmental temperature control is set.
Fill the system with glycol/water test medium.
Install the radiator, hose, or expansion tank in the test chamber.
Close front and rear doors to seal the chamber.
Set the desired pressure range, linear motion parameters, and temperature profiles in the control unit.
Start the test program via Windows/LabVIEW interface.
Monitor pressure, motion, temperature, and leak sensors throughout the test.
Automatically shut down any failed or leaking samples.
After testing, safely drain the test medium and allow the chamber to cool before removing samples.
Maintenance Information
Regularly inspect the motion drive, pressure sensors, and leak detection units for wear or damage.
Check glycol/water circulation system for blockages or leaks before each test.
Calibrate sensors and temperature controllers periodically to maintain measurement accuracy.
Clean environmental chamber surfaces and doors to prevent corrosion.
Replace worn seals, gaskets, or insulation as necessary to ensure safe operation.
Send product request
Other supplier products
| Light Fastness Test Instrument | Features and Benefits 1.The lightfastness test instrumentusexenon arc lamp as a radiation source, the visible light range emitted is 380nm-750nm, ... | |
| Rupture strength tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard IEC 61730-2: Photovoltaic (PV) Module Safety Qualification – Requirements f... | |
| STD Blowing Sand and Dust Test Chamber | Features and Benefits 1. Custom systems, the size and performance can be customized according to the customer's needs. 2. Automatically fill sand... | |
| Cabin Air Filter Test System(Particulate Filtration),Cabin Filter Efficiency Testing System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Test system for testing particle separation of air filters for passenger compartments (DIN ... | |
| Flex Durability Tester | The Flex Durability Tester is suitable for testing the rub resistance of various flexible films, composite films, and coated films. It is also know... |
Same products
| ISO 29463 HEPA/ULPA filter performance testing System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| Mobile Floor Scrubber Aging Life Tester IEC 60312 | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheMobile Floor Scrubber Aging L... | |
| ISO 12103 Cleanable Filter Media Test System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Robotic Vacuum Cleaners Edge-Following Tester | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheEdge-Following Test Equipment... |