Laboratory Fire Test System for Photovoltaic Modules

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The apparatus is designed to meet the requirements of the following standards:

(1) GB/T 30735-2014 – Test Method for Reaction to External Fire of Roofs and Roof Coverings

(2) ENV 1187: t1 – Test Methods for External Fire Exposure to Roofs

(3) ISO 12468-1:2013 (Method B) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods

(4) ISO 12468-1:2013 (Method C) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods

(5) UL 1703: multi-family and hotel room individual dwelling unit smoke detection monitors: electric signal detection of house dust;

(6)UL 790: standard method of fire test for roof covering materials;

(7)ASTM e 108-04: standard method of fire test for roof covering materials;

(8)NFPA 256: fire test of roof deck.

(9)IEC 61730-2 Appendix b: fire tests on PV modules.

Parameters

ItemSpecification
Radiant Panel Radiation Surface 600 mm × 600 mm
Wood Crib Fire Gas Combustion Device 1 set
Test Specimen Rack Angle Adjustable, 0–50°
Air Duct Material SUS304 stainless steel
Air Duct Thickness 2 mm
Fan Airflow Capacity Max. 250 m³/min
Fan Power 5.5 kW
Fan Frequency Control 3-phase 380 V, 5.5 kW
Air Duct Adjustable Angle 0–35°
Impeller Anemometer 3 units
Wind Speed Accuracy 0.1 m/s

Features

Frame-type structure for combustion and specimen holding systems, providing high mechanical stability.

Independent control cabinet and gas supply cabinet design, facilitating laboratory layout and improving operational safety.

Supplied with a compact stainless steel tube burner for wood shavings combustion tests.

Burner equipped with a silicon nitride igniter and UV flame detector, ensuring reliable ignition and real-time flame monitoring to prevent gas leakage.

Imported high-precision rotameter and branded pressure gauges for accurate control of fuel gas flow, combined with solenoid valves for automatic gas shutoff at the end of tests.

Specimen support frame constructed from welded metal square tubes and angle steel, ensuring rigidity during testing.

Adjustable specimen inclination angle using pneumatic actuation, allowing convenient push-button operation.

Fine honeycomb grille installed in the upper air duct and coarse honeycomb grille at the outlet to stabilize airflow.

Air duct angle adjustment driven by a ball screw and servo motor, enabling automatic and precise positioning.

Computer and dedicated software control the entire test process, ensuring convenient operation and reliable safety management.

Accessories

(1) Radiant panel assembly

(2) Wood crib fire gas combustion device

(3) Stainless steel tube burner

(4) Specimen support rack

(5) Air duct system with adjustable angle

(6) Centrifugal fan and frequency control unit

(7) Impeller-type anemometers

(8) Control cabinet and gas supply cabinet

(9) Computer and professional test software

Test Procedures

Specimen Installation

Mount the photovoltaic module or roofing specimen securely on the adjustable test rack and set the required inclination angle.

System Configuration

Adjust the air duct angle and configure the fan speed according to the selected test method and standard requirements.

Ignition and Heating

Activate the radiant panel and combustion system. For applicable tests, ignite the wood crib or burner using the silicon nitride igniter.

Fire Exposure Simulation

Expose the specimen to controlled thermal radiation and wind conditions to simulate external fire scenarios as defined in the selected method.

Monitoring and Recording

Monitor airflow velocity using the impeller anemometers and observe the combustion behavior of the specimen throughout the test.

Test Completion

After the test cycle is completed, the system automatically cuts off the gas supply and records test data for further evaluation.

Maintenance Information

Routine inspection of the burner, gas pipelines, solenoid valves, and flame detection system is recommended to ensure safe operation. The airflow system, including the fan, air duct, and honeycomb grilles, should be checked periodically for cleanliness and proper alignment. Moving components such as the specimen rack adjustment mechanism and air duct angle drive system should be maintained to ensure smooth operation. Electrical and control systems should be verified regularly according to laboratory safety procedures.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

CE Certified Belt Abrasion Tester Supplier China
CE Certified Belt Abrasion Tester Supplier China Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Belt Abrasion Tester is a laboratory testing instrument designed to evalu...
Fabric Fiber Shedding Degree Tester (Friction)
Fabric Fiber Shedding Degree Tester (Friction) Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fabric Fiber Shedding Degree Tester (Friction) is an instrument used to evaluate the li...
Artificial turf wear tester
Artificial turf wear tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard FIFA Quality Programme: Exceeds 2015/2016 handbook requirements for artificial tu...
Seatbelt Test Dummy ECE R16
Seatbelt Test Dummy ECE R16 Whats/App: +86 156 1874 6768 Web: standard-groups.com The ECE R16 crash test dummy is a professional anthropomorphic test device representing a 5...
Industrial Rubber Mooney Viscosity Testing Equipment ASTM International
Industrial Rubber Mooney Viscosity Testing Equipment ASTM International Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 1232 — Unvulcanized rubber: Determination of Mooney...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...