Textile Wet Adhesion Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
Domestic Standards:
T/CNGA 64-2024: Determination of Wet Adhesion of Clothing Fabrics
FZ/T: Reviewed and pending publication
International Standards:
ISO 105-F: Textiles – Tests for colorfastness – Wet and dry rubbing methods (relevant for adhesion effects under wet conditions)
ISO 13934-1 / ISO 13934-2: Textiles – Tensile properties of fabrics (for evaluating mechanical response during wet adhesion testing)
ISO 105-E04: Textiles – Colorfastness to perspiration (simulates wet fabric-skin interaction)
ASTM D5034: Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (relevant for wet tensile performance)
ASTM D2594: Standard Test Method for Pilling Resistance and Other Related Surface Changes of Fabrics (to indirectly assess wet adhesion effects)
EN 31092: Textiles – Physiological effects – Measurement of water vapor resistance of clothing fabrics (indirectly related to comfort under wet adhesion conditions)
AATCC TM79: Absorbency of Textiles – Evaluating wetting behavior relevant to adhesion and comfort
Product Features
(1) Four-level evaluation system for wet adhesion performance (Level 1: Excellent – Level 4: Poor).
(2) High-precision force measurement with 0.03% FS accuracy.
(3) Adjustable test speed from 1–100 mm/min for versatile testing.
(4) Servo-controlled movement with Panasonic motor and driver for stability and repeatability.
(5) Compact, ergonomic design suitable for laboratory environments.
Technical Specifications
| Parameter | Specification |
|---|---|
| Maximum Load | 300 g |
| Force Measurement Range | 0.4% – 100% FS |
| Measurement Accuracy | ±0.03% FS |
| Test Speed | 1–100 mm/min |
| Maximum Displacement | 80 mm |
| Displacement Accuracy | 10 μm |
| Servo Motor / Driver | Panasonic |
| Dimensions (L×W×H) | 545 × 419 × 509 mm |
| Power Supply | AC 220V ±10%, 400 W |
| Weight | 25 kg |
Accessories
Sample clamps and holders
Calibration weights
Servo motor driver interface
Protective covers
Test Procedures / Maintenance
(1) Secure the wet fabric sample on the fixture.
(2) Adjust the test speed and maximum displacement according to the material and standard.
(3) Start the servo motor to measure adhesion force while the fabric is in a wetted state.
(4) Record adhesion force and assign performance level based on four-level system.
(5) After testing, clean the sample holder and surrounding area to avoid residue.
(6) Periodically calibrate the force sensor and servo system to maintain accuracy.
在线联系供应商
Other supplier products
| 50th Percentile Male Crash Test Dummy (Standing) | Whats/App: +86 156 1874 6768 Web: standard-groups.com The 50th Percentile Male Crash Test Dummy (Standing) is a biomechanical surrogate designed ... | |
| Rattle tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Bell Rattle Toy Tester: Also known as: Sound-emitting toy tester Toy test template AB A... | |
| Aerosol Foams Flammability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction This product complies with "Recommendations on the Transport of Dange... | |
| 16-Segment Heated Thermal Manikin (Dry Type) | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The 16-Segment Heated Thermal Manikin is used in the following application are... | |
| Laboratory Haptic Skill Logging System for Touch Sensitivity Research | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards At present, there is no dedicated international standard specifica... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |