Custom Pressure Transmission Flow Meter Test Instrument
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The design and manufacture of the Pressure Transmission and Flow Tester need to comply with relevant industry standards and technical specifications to ensure the accuracy and reliability of test results. Common compliance standards include, but are not limited to: GB/T 19335 - 2022 General Technical Requirements for Disposable Blood - path Products, etc.
Features
• The instrument has three test modes: pressure transmission performance, blood occlusion, and puncture device flow rate.
• Equipped with a dual-sensor, vacuum generator, and precise pressure testing system, the testing accuracy is significantly improved.
• Embedded high-speed microcomputer chip control and a simple and efficient human-machine interface provide users with a comfortable and smooth operating experience.
• Equipped with a precision pressure regulating valve for high-precision pressure range adjustment.
• A 7-inch color touch screen combined with intelligent data processing functions provides users with a comfortable and smooth operating experience.
• Simple and intuitive operation interface, convenient user-defined test functions, and comprehensive data analysis and reporting functions.
• Simple and convenient operation process, a brand-new UI interface design, and an intuitive operation interface greatly enhance the user experience.
• Automatic result determination and printable test data.
• Supports quick viewing and printing of historical data.
• The instrument comes with a built-in miniature printer and powerful data storage capabilities, storing up to 50.000 data entries.
• Equipped with a standard RS232 communication port for convenient external connection and data transmission between the system and a computer.
• Energy-saving and environmentally friendly design, aesthetically pleasing appearance, and ultra-low power consumption power supply meet national energy-saving and environmental protection requirements.
Technical Parameters
| Serial No. | Parameter Item | Parameter Details |
|---|---|---|
| 1 | Testing Range (Pressure) | 0 - 10 KPa (standard configuration); customizable according to actual needs |
| 2 | Testing Range (Flow) | Depends on specific model and configuration; usually covers a wide flow range |
| 3 | Accuracy (Pressure Testing) | 0.5%FS (full-scale error); ensures the accuracy of test results |
| 4 | Accuracy (Flow Testing) | Depends on specific model and configuration; meets high-accuracy requirements |
| 5 | Air Source Pressure | ≤0.7 MPa (user-provided); ensures the normal operation of the tester |
| 6 | Air Source Interface | Φ8 mm polyurethane tube or other standard interfaces; facilitates air source connection |
| 7 | Power Supply | Voltage and frequency vary by model; supports wide voltage range (adapts to different regional electrical standards) |
| 8 | External Dimensions | Main unit: 300 mm(L)×410 mm(W)×150 mm(H) (varies by model); easy to place and operate |
| 9 | Weight | Moderate; easy to carry and move |
| 10 | Other Functions (Data Recording & Storage) | Real-time data recording and storage; convenient for subsequent analysis and processing |
| 11 | Other Functions (Display & Operation Interface) | Color touch-screen interface; supports Chinese-English switching (or other languages); clear and easy to operate |
| 12 | Other Functions (Automatic Calibration & Fault Diagnosis) | Some models have automatic calibration (ensures test accuracy) and fault diagnosis (facilitates timely problem detection/resolution) |
Accessoriess
Standard configuration: Main unit, miniature printer, air supply connection pipe, hydraulic leak-proof device
Note: The air source interface of this machine uses an 8mm polyurethane tube; the air source must be provided by the user.
Test Procedures
1. Preparation Before Operation
Equipment and Environment Check:
Confirm that the instrument's power supply (wide voltage adaptable) and gas line interfaces (Φ8mm polyurethane tubing) are in normal condition; place the equipment on a ventilated, temperature-stable (20±5℃) workbench, ensuring no airflow interference.
Sample and Consumable Preparation:
Prepare the fluid system components to be tested (e.g., pipes, valves, sensors), ensuring the components are clean and undamaged; prepare a suitable gas source (provided by the user, pressure ≤0.7MPa).
Standard Matching:
Confirm the standards that the test needs to comply with, and clarify the pressure and flow rate test indicators.
2. Equipment Calibration
Start the instrument and access the "Calibration Interface" via the color touch screen;
Perform automatic calibration of the pressure sensor (according to 0.5% FS accuracy requirements) and flow module (supported by some models), or perform manual calibration using a standard pressure/flow source to ensure test accuracy.
3. Parameter Settings
Select the corresponding standard on the touch screen interface;
Set test parameters:
Pressure test range: Default 0-10KPa (customizable as needed);
Flow rate test range: Match the actual flow rate range of the component under test;
Test duration: Set the continuous test cycle according to the component characteristics.
4. Sample Installation
Connect the fluid components to be tested (e.g., pipes, valves) to the input/output terminals of the instrument via standard gas line interfaces (Φ8mm polyurethane tubing);
Check the connection for airtightness (to avoid air leaks affecting test results), ensuring the components are securely installed and not twisted.
5. Test Execution
After confirming that the parameters and sample installation are correct, click "Start Test";
The instrument automatically runs according to the set parameters: controlling the gas source pressure transmission, synchronously collecting flow rate data, and recording indicators such as pressure transmission efficiency and flow characteristics in real time;
Monitor the data curve via the touch screen during the test. If any abnormalities occur (e.g., pressure/flow rate fluctuations exceeding limits), the test can be paused to troubleshoot the problem.
6. Data Processing and Report Generation
After the test is completed, the instrument automatically stores the real-time data;
Export a test report containing "pressure transmission data, flow characteristic curves, and compliance with standard judgment" for:
Fluid system performance evaluation: verifying whether the system meets design/usage requirements;
Product quality control: checking whether the component quality meets industry standards.
7. Post-Test Maintenance
Disconnect the air supply and power, remove the tested component, and clean any remaining impurities from the air circuit connections;
Record the instrument's operating status, and regularly re-check and calibrate it to ensure long-term stable operation of the equipment.
在线联系供应商
Other supplier products
| UV fade meter Si48 for textile testing | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com UV Long-Life Auto Fade Meter is extensively used for colour fastness test of ... | |
| GB/T 28752 IMO Heat Radiation Flame Spread Test Apparatus,Thermal Radiation Flame Propagation Test Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Building Industry Flame spread testing of construction materials such as wall... | |
| Automatic Wyzenbeek abrasion tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard Test ASTM D3597:Standard Test Method for Resistance to Yarn Slippage in Woven Fab... | |
| Scratch Resistance TesterScratch Resistance Tester,ASTM D7027 automatic scratch resistance tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Scratch 5.5 Machine is a research-grade tribology instrument for macroscopic scratch an... | |
| Fiber Crimp Elasticity Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fiber Crimp Elasticity Tester is a specialized instrument designed to measure the crimp... |
Same products
| 不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 | 卖方: 863048 | 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,... | |
| E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 | 卖方: 863048 | 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан... | |
| Mini Jewelry Laser Repair System – 60W to 400W Precision Welding | 卖方: Beijing JCZ Technology Co., Ltd | The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre... | |
| Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal | 卖方: Beijing JCZ Technology Co., Ltd | TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig... | |
| Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner | 卖方: Beijing JCZ Technology Co., Ltd | The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las... |