Aluminum tube coating continuity inspection device

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The design and manufacture of the continuity tester for the inner coating of aluminum tubes usually comply with a series of national and international standards to ensure the accuracy and reliability of test results. Among them, common standards include YBB00162002 - 2015 Aluminum Pharmaceutical Soft Tubes, etc. These standards specify in detail the test methods, specimen preparation, test conditions, etc. for the continuity of the inner coating of aluminum tubes, providing a unified standard for the use of the tester.

Features

1. High Specialization: Specifically designed for continuous testing of the inner coating of aluminum tubes, compatible with common aluminum tube specifications of 8-45mm diameter and 35-250mm length, covering most industry application scenarios.

2. High Testing Accuracy: Current measurement accuracy reaches ±0.1mA, accurately identifying minute coating damage and ensuring reliable test results.

3. Flexible Adaptability: The test voltage is adjustable (e.g., DC 5V±0.5V), matching the testing needs of different coating materials and thicknesses.

4. Portable and Easy to Deploy: Compact and lightweight, it can be flexibly deployed in various scenarios such as production sites and laboratories.

5. Multi-Scenario Coverage: Supports full-process applications including raw material quality inspection, new product R&D assistance, and in-use product quality control, contributing to quality management.

Technical Parameters

Technical ParameterSpecification
Testing Range Applicable to aluminum tubes with a diameter between 8 and 45mm and a tube length between 35 and 250mm (covers most common aluminum tube specifications, ensuring wide applicability).
Testing Accuracy Usually high; e.g., current measurement accuracy can reach ±0.1mA. High-precision measurements support quality control and product R&D.
Testing Voltage Usually adjustable within a certain range, such as DC 5V±0.5V. Adjusting voltage meets testing requirements of different coating materials and thicknesses.
Input Voltage and Power Supply Input voltage: AC 220V 50Hz (standard voltage in most regions); equipped with a stable power supply system to ensure voltage stability and data accuracy.
Appearance Dimensions and Weight Usually compact and portable (varies by model/brand), enabling use in different production sites and laboratories.
Working Environment Working temperature: 23℃±2℃; relative humidity: not exceeding 80% (without condensation). Ensures normal operation and test result accuracy.

Accessoriess

Multi-size aluminum tube clamps: Adaptable to aluminum tubes with diameters of 8-45mm and lengths of 35-250mm, ensuring stable sample clamping.

Standard calibration aluminum tubes: Aluminum tube samples with known coating conditions, used for periodic accuracy calibration of the equipment.

Internal coating electrode probe: The detection component that contacts the inner coating of the aluminum tube, ensuring stable transmission of electrical signals.

Data transmission cable: Connects the equipment to a computer, enabling the export and storage of test data.

Probe cleaning brush: Cleans the surface of the electrode probe to prevent coating residue from affecting detection accuracy.

Test Procedures

1. Equipment Preparation

Connect to AC 220V 50Hz power supply. Confirm the working environment (23℃±2℃, humidity ≤80%, non-condensing). After powering on and preheating, calibrate the equipment using a standard calibration aluminum tube.

2. Sample Preparation

Select the aluminum tube to be tested and clean its inner surface (remove impurities). Confirm that the dimensions are within the equipment's testing range.

3. Parameter Setting

Set the test voltage (e.g., DC 5V±0.5V) through the equipment interface, matching the coating material and thickness.

4. Sample Clamping

Fix the aluminum tube in the corresponding specification clamp, ensuring full contact between the electrode probe and the inner coating.

5. Start Testing

Run the testing program. The equipment automatically detects the electrical continuity of the coating and records the data.

6. Result Determination

Determine whether there are defects such as discontinuities or breaks in the coating based on the current data.

7. Post-processing

Remove the sample, clean the electrode probe, export the data, and generate a test report.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Bottle Wall and Bottom Thickness Tester
Bottle Wall and Bottom Thickness Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The wall and bottom thickness tester for bottles is mainly used to measure th...
Environmental Stress Cracking Resistance Tester
Environmental Stress Cracking Resistance Tester This instrument is a testing device recommended according to standard requirements. It is a specialized device designed specifically for environmen...
Battery Powder resistance tester
Battery Powder resistance tester The Powder Resistivity Meter is a precision testing system designed to measure electrical resistivity, conductivity, and related properties of powd...
fabric wet adhesion performance tester
fabric wet adhesion performance tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Overview The Fabric Wet Adhesion Performance Tester is a precision instrument desi...
Finished shoe bending tester丨Finished shoe bending test mechine
Finished shoe bending tester丨Finished shoe bending test mechine Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Finished shoes bending testing machine Finished shoes bending testin...
供应产品

Same products

Benchtop Thermal Conductivity Tester for Insulation Materials
Benchtop Thermal Conductivity Tester for Insulation Materials 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with a...
High-Accuracy Guarded Heat Flow Meter Thermal Conductivity Measurement System
High-Accuracy Guarded Heat Flow Meter Thermal Conductivity Measurement System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed and...
Heat Flow Method for Thermal Conductivity Measurement
Heat Flow Method for Thermal Conductivity Measurement 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with a...
Benchtop Thermal Conductivity Tester
Benchtop Thermal Conductivity Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed and...
Guarded Heat Flow Measurement System
Guarded Heat Flow Measurement System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM E1530: Standard Test Meth...