The Fabric Anti-Electromagnetic Radiation Performance Tester is a precision instrument designed to measure the electromagnetic shielding effectiveness of various materials, including textiles, plastic sheets, metal foils, coatings, platings, conductive films, metal meshes, conductive glasses, and conductive medium plates. The tester employs the coaxial test method, providing high accuracy and reliable results for full-frequency, list, and point-frequency measurements.
Application
This tester is widely used for:
Evaluating shielding performance of electromagnetic shielding fabrics for garments and protective materials.
Testing coatings, conductive films, and metal meshes for electronics, aerospace, and automotive applications.
Assessing absorptive and reflective properties of planar materials against electromagnetic waves.
Research and development of EMI/EMC compliant textiles and composite materials.
Quality control in textile manufacturing and material certification labs.
Standards
GB/T 23326 – Electromagnetic shielding textile test standard (China)
GB/T 25471 – Electromagnetic shielding material testing method (China)
ASTM D4935 – Standard test method for measuring the electromagnetic shielding effectiveness of planar materials using a coaxial transmission line
SJ2054 – Coaxial method for conductive materials (China)
Features
(1) Uses coaxial test method, ensuring high transmission characteristics and testing accuracy.
(2) Supports full-frequency scanning, list scanning, and point-frequency measurements.
(3) Automatic control of signal emission and reception, data collection, curve display, and micro-printer output.
(4) Evaluates both absorption and reflection performance of planar materials.
(5) RS232 interface for computer connection, curve display, data analysis, and storage.
(6) USB interface for mobile data storage via flash drives.
(7) User-friendly interface with automated measurement and data processing.
Technical Parameters
1. Signal Source
| Parameter | Specification |
|---|---|
| Frequency Range | 300 KHz – 3000 MHz |
| Frequency Stability | ≤ ±5×10⁻⁶ |
| Frequency Resolution | 1 Hz |
| Signal Purity | ≤ -65 dBc/Hz (10 KHz offset) |
| Output Level | -45 dBm – +10 dBm |
| Level Accuracy | ±1.5 dB |
| Harmonic Suppression | ≥30 dB (1 MHz–3 GHz), ≥25 dB (300 KHz–1 MHz) |
| Directivity | ≥50 dB |
| Power Scanning | -8 dBm – +5 dBm |
| System Impedance | 50 Ω |
2. Receiver
| Parameter | Specification |
|---|---|
| Frequency Range | 300 KHz – 3000 MHz |
| Resolution Bandwidth | 100 Hz – 20 KHz |
| Dynamic Range | ≥95 dB (RBW = 1 KHz) |
| Maximum Input Level | +10 dBm |
| Input Damage Level | +20 dBm (DC +25V) |
| Standing Wave Ratio | ≤1.2 |
3. Phase Characteristics
| Parameter | Specification |
|---|---|
| Phase Resolution | 0.01° |
| Phase Trajectory Noise | 0.5° @ RBW 1 KHz; 1° @ RBW 3 KHz |
4. Transmit and Receive Frequencies
| Parameter | Specification |
|---|---|
| Transmit Frequency | 20 MHz – 1.3 GHz |
| Transmit Frequency Drift | <1000 Hz |
| Minimum Hopping Interval | 1 MHz |
| Transmit Output Power | >13 dBm |
| Receive Power Dynamic Range | +5 dBm – -55 dBm |
| Receiver Power Accuracy | ±1 dB |
| Resolution | 0.01 dB |
| Receiver Frequency Test Range | 10 MHz – 3 GHz |
| Double-layer Shielding Effectiveness | >20 dB |
5. Specimen Dimensions
| Parameter | Specification |
|---|---|
| Circular Specimen | Diameter 180–200 mm |
| Square Specimen | 180×180 mm – 200×200 mm |
| Thickness | 0–5 mm |
6. Instrument Specifications
| Parameter | Specification |
|---|---|
| Working Environment | 0–40°C, 0–75% RH |
| Power Supply | AC 220V ± 30V, 50 Hz, 100 W |
| Dimensions | 70×50×75 cm (L×W×H, excluding computer) |
| Weight | Approximately 75 kg |
Accessories
Main unit (coaxial testing module)
Branded computer for data analysis
Branded printer for reports
RS232 and USB cables for data transfer
在线联系供应商
Other supplier products
| Intervertebral Fusion Cages Torsion Fatigue Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0959-2014 (China): Specifies torsional fatigue testing protocols for interve... | |
| Safety Helmets Against Molten Metal Splashing Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 2812-XXXX: Safety Helmets – Test Methods for Molten Metal Resistance (... | |
| Flame Penetration Fuel Test System for Thermal and Acoustic Insulation Materials | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Flame Penetration Fuel Test System for Thermal and Acoustic Insulation Materials is a d... | |
| Large-Area LED Solar Simulator 3A+ Manufacturer | IEC 60904-9 Class AAA+ Solar Simulation | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) IEC 60904-9 – Photovoltaic Devices: Performance Requirem... | |
| Dusting solar cell modules Test System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications tests according to VDI 3956 temperature-dependent dusting and cleaning tests... |
Same products
| 不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 | 卖方: 863048 | 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,... | |
| E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 | 卖方: 863048 | 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан... | |
| Mini Jewelry Laser Repair System – 60W to 400W Precision Welding | 卖方: Beijing JCZ Technology Co., Ltd | The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre... | |
| Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal | 卖方: Beijing JCZ Technology Co., Ltd | TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig... | |
| Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner | 卖方: Beijing JCZ Technology Co., Ltd | The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las... |