Full Vehicle Sunlight Simulation Test Chamber

Get a quote:

Whats/App: +86 181 0160 0864

The Full Vehicle Sunlight Simulation Test Chamber is a high-precision environmental testing facility designed to replicate intense solar radiation and extreme climate conditions. By integrating a full-spectrum lighting system with precise temperature and humidity controls, this chamber allows you to evaluate how entire vehicles or large-scale automotive components respond to prolonged sunlight exposure. It provides a controlled laboratory environment to assess material degradation, thermal expansion, and functional reliability under peak solar loads.

Applications

Full Vehicle Sunlight Simulation Test Chamber is designed to evaluate the aging performance of complete assemblies or entire vehicles under sunlight exposure. Users can assess changes in performance after irradiation, including alterations in shape, color, gloss, texture, strength, and various thermal expansion results. Additionally, it tests key metrics such as vehicle starting capability, motor performance, and overall air conditioning functionality under solar radiation.

Standards

GB/T 12535-2007 Test Methods for Starting Performance of Automobiles

GB 11556-2009 Defrosting and Demisting Test

GB/T 18297-2001 (Reference) Motor Performance Test

GB/T 2423.24-1995 Solar Radiation Test

GB/T 2423.3-2006 Test Method for Constant Humidity and Heat

GB/T 12782-2007 Requirements and Test Methods for Automotive Heating Performance

QC/T 658-2000 Test Method for Automotive Air Conditioning System Performance

Features

1. This vehicle-level solar simulation test chamber is designed for performance testing of electric vehicles with motor power ≤150kW, providing environmental simulation conditions ranging from -20°C to +60°C.

2. Functionality and volume can be customized according to different vehicle models and testing standards.

Parameters

CategorySpecifications
Temperature Control Range -20°C ~ +60°C
Humidity Range Relative humidity: 30% ~ 95%, no condensation in the low-temperature test chamber• Without illumination: 30% ~ 95% RH• With illumination: 30% ~ 80% RH
Condition Control a. Cooling Time• 25°C ~ -20°C: ≤ 85 min (no load)• 60°C ~ 25°C: ≤ 40 min (no load)b. Heating Time• -20°C ~ 25°C: ≤ 50 min (no load)• 25°C ~ 60°C: ≤ 50 min (no load)c. Temperature Fluctuation• ≤ ±0.5°C (no load)d. Temperature Uniformity• ≤ ±1.5°C (no load)e. Temperature Deviation• ≤ ±2.0°C (with load, measured at vehicle front air inlet, roof, left and right sides)
Illumination System a. Infrared Radiation Lamps• Working ambient temperature: -20°C ~ 60°C• Maximum radiation intensity: 1200±25W/m², uniformity: ±10%• Adjustment range: 30% ~ 100%b. Simulated Lamps• Uses two-terminal linear medium-wave infrared simulation lamps• Service life: ≥ 5000h (radiation intensity remains stable during this period)c. Illumination Adjustment• Automatically and manually adjustable via temperature control on the vehicle surfaced. Projection Area & Movement• Projection area: 5000mm × 2500mm (L×W)• Vertical movement distance: Minimum 2200mm, maximum 3000mm (distance from the lower surface of the lamp to the chamber bottom)

Accessories

1.Solar Simulation Array: Vertically adjustable lamp rack with medium-wave IR lamps.

2.Humidity Control System: Includes a high-pressure water spray and dehumidification unit.

3.Sensor Package: High-precision temperature and humidity sensors, plus pyranometers for radiation monitoring.

4.Vehicle Interface Port: Sealed pass-throughs for vehicle exhaust and data cables.

5.Safety System: Over-temperature protection, emergency stop, and smoke detection alarms.

Test Procedures

1. Equipment and Sample Preparation

Equipment Inspection: Verify that the solar simulator chamber's irradiance (1000 W/m²), temperature (-40°C to 110°C), humidity (5%–95% RH), and air velocity (0.5–10 m/s) parameters comply with standards.

Sample Installation: Position the test vehicle at the chamber center, ≥0.3m from chamber walls, with ≥0.76m distance from radiation lamps.

2. Test Implementation

Cycle Test:

Cycle Count: Minimum 3 cycles, maximum 7 cycles, each lasting 24 hours.

Irradiance Control: Adjust in segments or continuously to maintain constant total energy.

Temperature Regulation: Set ambient and radiation temperatures according to test requirements.

Humidity Regulation: Control surface humidity via a water spray system.

Steady-State Test:

Cycle Count: Determined by exposure duration (e.g., 4 cycles for a 10-day test).

Parameter Settings: Maintain stable irradiance, temperature, and humidity.

3. Performance Testing

Initial Inspection: Record specimen appearance, temperature sensor data, and operational performance before testing.

Intermediate Inspection: Conduct visual inspection, dimensional measurement, and electrical testing at peak temperature.

Final Inspection: Evaluate performance changes post-testing to ensure compliance with product specifications.


在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Automatic Thermal Deformation Vicat Softening Point Tester
Automatic Thermal Deformation Vicat Softening Point Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk This machine is a non-metallic material testing instrument designed and manufactur...
MARK-II Slip Resistance Tester ASTM F1677
MARK-II Slip Resistance Tester ASTM F1677 Product Introduction: Paste the cut sample on the test fixture of the portable MARK-II anti-slip testing machine, put down the weight of the rotat...
Guide pin anchoring force tester
Guide pin anchoring force tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Guide Pin Anchoring Force Tester is designed to evaluate the anchoring perform...
Industrial Dry Cleaning Machine
Industrial Dry Cleaning Machine Getaquote: Whats/App: +86 181 0160 0864 The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the compres...
Building Material Flammability Test Furnace
Building Material Flammability Test Furnace Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The touch screen-controlled building materials flammability test furnace, upgraded...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...