.

Manikin Coughing System(Cough Simulator)

Get a quote:

Whats/App: +86 181 0160 0864

Web: gellowen.co.uk

The Manikin Coughing System (Cough Simulator) is a high-precision experimental device designed to operate with a thermal manikin or a manikin head, or as an independent unit. It is used to simulate realistic human coughing conditions. By adjusting cough airflow rate, initial jet velocity, pressure, and duration, you can study aerosol particle dispersion and transmission under indoor or confined-space airflow conditions. The system provides reliable experimental data for indoor air quality studies, pollutant exposure assessment, and airborne infectious disease research.

Application

HVAC research and education, including indoor air quality evaluation, breathing and coughing exposure risk assessment in confined spaces, and cross-infection risk analysis of airborne diseases;

Medical and public health research, including simulation of pathogen-laden cough particle dispersion and airborne disease studies;

Occupational hygiene assessment, such as exposure risk evaluation of dust, PM2.5, and gaseous pollutants in workshops and factories;

Human exposure risk assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;

Exposure assessment and air-conditioning system optimization in vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;

Public health and military medical research in high-occupancy or densely populated environments.

Standards

GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)

GB/T 18883-2022 — Indoor Air Quality Standard

ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort

ASTM F1291-2020 — Test Methods for Breathing and Coughing Exposure Measurement

Product Specifications

ComponentTechnical Parameters
Cough Pressure Adjustable range 0.1–4.2 bar
Initial Cough Airflow Velocity Adjustable range 0.5–30 m/s
Cough Duration Adjustable range 0.1–60 s
Cough Outlet Mode Nasal or oral outlet; compatible with thermal manikin or manikin head
Aerosol Container Venturi-type aerosol solution container supplied by the user
Electrical Control System Integrated control cabinet; power supply AC 220 V / 50 Hz; maximum total power ≤ 250 W
Operating Environment Temperature 10–40 °C; humidity 15–95%
Others Can be used independently or with a thermal manikin/manikin head; lockable caster wheels; automatic over-pressure relief and short-circuit protection; total weight approx. 20 kg

Features

Accurate simulation of human coughing pressure, initial airflow velocity, and duration with wide adjustable ranges;

Switchable nasal or oral coughing modes to meet different experimental requirements;

Modular design supporting standalone use or integration with a thermal manikin or manikin head;

Aerosol output compatible with external sampling devices, suitable for pathogen or particle research;

Built-in over-pressure protection and short-circuit protection for safe operation;

Mobile platform with lockable caster wheels for flexible laboratory deployment.

Accessories

Accessory / ConsumableSpecification
Cough Control Cabinet PID control module with pressure and flow display
Cough Airflow Outlet Tube Connects to thermal manikin or manikin head interface
Aerosol Container Venturi-type aerosol solution container provided by the user
Quick-Connect Interfaces For fast connection to thermal manikin or manikin head
Custom Modules Pressure, flow, and coughing mode adjustable according to test requirements

在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Ross Flex Tester | Ross Bending Machine
Ross Flex Tester | Ross Bending Machine Whole Sole ROSS Flexing Tester GT-KB05D To determine right angle flexing risistance for whole sole of rubber, PU, PVC, TPR foam and other materials...
Safety Footwear Electrical Hazard Tester
Safety Footwear Electrical Hazard Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Safety Footwear Electrical Hazard Tester is designed to evaluate the dielectri...
Non-contact Color Measuring Instrument
Non-contact Color Measuring Instrument Get a quote: Whats/App: +86 181 0160 0864 The Non-Contact Color Measuring Instrument is a high-precision device designed for color measurement, m...
Shoelace anti-siphon tester 丨Shoelace Tester
Shoelace anti-siphon tester 丨Shoelace Tester Product Introduction Shoelace anti-siphon tester is suitable for all kinds of waterproof leather, leather, mesh, waterproof shoelace, ribbon water...
Pumpability tester EN 12723 ISO 5198
Pumpability tester EN 12723 ISO 5198 Product Introduction The pumpability tester is dedicated to accurately testing the pumpability of the shield tail seal grease used in shield const...
供应产品

Same products

Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 卖方: 868983 Common Rail Injector Valve F00R J02 012 David Chen
Common Rail Injector Valve F00R J02 005
Common Rail Injector Valve F00R J02 005 卖方: 868983 Common Rail Injector Valve F00R J02 005 David Chen
Common Rail Injector Valve F00R J01 945
Common Rail Injector Valve F00R J01 945 卖方: 868983 Common Rail Injector Valve F00R J01 945 David Chen
Common Rail Injector Valve F00R J01 941
Common Rail Injector Valve F00R J01 941 卖方: 868983 Common Rail Injector Valve F00R J01 941 David Chen
Common Rail Injector Valve F00R J01 924
Common Rail Injector Valve F00R J01 924 卖方: 868983 Common Rail Injector Valve F00R J01 924 David Chen