Catheter Flow Meter

Get a quote:

Whats/App: +86 181 0160 0864

Web: gellowen.co.uk

The Catheter Flow Meter is specifically designed for measuring the water flow rate of medical catheters, including non-vascular catheters, intravascular catheters, and single-use sterile catheters. It is also known as a catheter flow meter, catheter flow detector, non-vascular catheter flow device, infusion set flow tester, or medical device flow tester.

Applications

The catheter flow tester is mainly used to measure and evaluate the flow performance of medical catheters, such as intravascular catheters, non - intravascular catheters, and infusion set catheters. In the medical field, this tester has a wide range of applications, including but not limited to the following aspects: Product R & D: During the design and R & D stage of catheter products, the tester can help engineers accurately assess the flow performance of different design schemes, providing powerful data support for product iteration. Quality Control: Through batch testing, the tester can ensure that each batch of catheters meets the established flow standards and performance requirements, thus improving the overall quality of products. Clinical Application: The tester can be used to monitor the flow changes of catheters in patients, providing real - time physiological parameter feedback to doctors, which is helpful for adjusting treatment plans, assessing the progress of the disease, and preventing complications.

Standards

GB/T 15812.1 - 2005 Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods

YY 0285.1 - 2017 Disposable Sterile Intravascular Catheters

Features

• Independently developed hydrostatic pressure testing device, capable of maintaining a liquid level of 1000 ± 10 mm.

• Flow rate of 525 ml/min, meeting standard flow rate requirements.

• Equipped with a constant temperature water bath to ensure the test water temperature is 23℃.

• Equipped with a timer for timed testing.

• Test fixture designed strictly according to standard requirements, easy to operate and highly efficient.

• Uniquely designed lifting and lowering structure allows for height adjustment, facilitating testing at different water pressures.

• Equipped with a balance station for convenient placement of balances or measuring cylinders.

• Equipped with an adjustable precision water pump for easy flow rate adjustment.

Technical Parameters

ParameterSpecification
Testing Range Usually within a weight/volume range (e.g., 1.00 - 600.00g, varying by catheter specifications) or a specific flow range
Accuracy High testing accuracy (e.g., ±0.01%FS, one-ten-thousandth of full scale) or higher requirements
Static Water Level Height e.g., 200±5mm, 1000±5mm (meets different testing needs); water pump has automatic circulation function; static water level is adjustable
Time Controller Usually 0 - 60min, with an error ≤ ±1S; used to control testing time
Fixtures Adapt to various catheter specifications/types, ensuring test versatility and flexibility
Flow Calculation Generally uses the weighing method (imported flowmeters optional) to calculate flow, ensuring result accuracy
Flow Rate e.g., 525ml/min (arbitrary selection) ±25ml/min, etc.; adapts to different testing scenarios
Intelligent Temperature Control Equipped with a micro-computer intelligent temperature-control system, ensuring constancy and accuracy of test temperature
Special Accessories Includes stainless-steel thermostatic water baths, special connectors, etc.; meets testing needs of different catheter specifications/types

在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Vertical Fire Resistance Test Furnace for Building Elements
Vertical Fire Resistance Test Furnace for Building Elements Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Vertical Fire Resistance Test Furnace for Building Elements is designed for fi...
Single chip liquid crystal touch impact testing machine
Single chip liquid crystal touch impact testing machine Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Liquid crystal touch impact testing machine is mainly used for hard plastics (incl...
Torque Rheometers
Torque Rheometers Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Torque rheometer is ideal for studying polymer flow, deformation, plasticization, ...
Smoke Density Tester
Smoke Density Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Smoke Density Tester, developed by Rohm and Haas in the 1970s based on ASTM D2...
Electric Rubbing Colour Fastness Tester/Crockmeter
Electric Rubbing Colour Fastness Tester/Crockmeter Get a quote: Whats/App: +86 181 0160 0864 G238CC Electronic rubbing colour fastness tester is used for testing the color fastness of fabric and l...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...