ISO 5658 Surface Flame Spread Test Machine Exporter Industrial Use
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Parameters
| Parameter Category | Details |
|---|---|
| Dimensions | 1760 × 1450 × 2130 mm |
| Weight | 678 kg |
| Radiation Panel | 850 × 850 mm |
| Power Supply | 220V, 50Hz, 10A |
| Operating Temp | 10°C – 35°C |
| Gas Requirements | Industrial propane, compressed air |
Features
Large Radiation Panel: 850 × 850 mm with reinforced structural support.
Vertical Sample Holder: Includes standard scale markings to measure flame spread distance and critical heat flux.
Water-Cooled System: Prevents sample holder damage during long-duration high-temperature testing.
Small Flame Ignition: Uses electric spark ignition for consistent flame application.
Automatic Safety Cut-Off: High-temperature sensors shut off gas supply if the radiation panel extinguishes.
Calibrated Heat Flux Sensors: Traceable to NIST for accurate radiation flux measurement.
Digital Control Box: Allows adjustment of gas and air flow with digital display of radiation flux.
PLC & HMI Integration: Displays all test parameters for real-time monitoring and control.
Accessories
Water-cooled sample holder
Calibrated porous panel
Heat flux sensors
Electric spark ignition system
PLC & HMI control system
Gas and air flow regulation valves
Safety interlock devices
Test Procedures
Ensure a minimum of 5 meters of clear space around the installation area.
Connect the apparatus to 220V, 50Hz, 10A power supply.
Supply industrial propane and compressed air to the system.
Mount the test sample vertically on the water-cooled holder.
Adjust the radiation panel and calibrate heat flux sensors.
Ignite the sample using the small flame ignition system.
Monitor flame spread distance and propagation speed using the scale markings and digital sensors.
Record data for critical heat flux and flame spread classification.
After testing, shut off gas and air supply and allow the apparatus to cool before sample removal.
Maintenance Information
Regularly inspect and clean the radiation panel and water-cooled holder.
Check gas and air supply lines for leaks before each test.
Calibrate heat flux sensors periodically to maintain traceability.
Inspect electrical connections and PLC/HMI for operational stability.
Replace worn or damaged safety interlocks immediately.
在线联系供应商
Other supplier products
| Deval Abrasion Testing Machine | EN 1097-1 Aggregate Abrasion Tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) JTG 3432-2024: Aggregate Test Regulations for Highway Engineer... | |
| Wet leakage current test system of photovoltaic module | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and... | |
| Automatic Sock Stretch Recovery System | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Sock Stretch Tester is a precision instrument designed to evaluate the el... | |
| Minimum Ignition Energy (MIE) – Dust Cloud Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Description: Dust Cloud Minimum Ignition Energy Tester disperses a certain mass of dust sp... | |
| Automatic Long Filament Curl Shrinkage Tester | ISO 1805 Filament Crimp Testing Machine | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Automatic load adjustment and application ensures precise force... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |













