Minimum Ignition Temperature (MIT) – Dust Cloud Tester
Dust Cloud Minimum Ignition Temperature Tester is mainly used to assess the explosiveness of dust in the production and processing places such as aluminum powder, zinc powder, plastic powder, intermediates of organic synthetic pharmaceuticals, wheat flour, sugar, wood chips, dyestuffs, glued wood ash, milk powder, tea powder, tobacco powder, coal dust, plant fiber dust and so on, and to accurately determine the minimum ignition temperature of the dust cloud.
Applications
1. Chemical/Pharmaceutical Industry: Testing the MIT (Mixed Explosion-Proof) of dust clouds for organic synthesis intermediates, plastic powders, dye dust, etc., for: Designing explosion-proof workshops (e.g., determining upper limits for ventilation temperatures); Compliance testing with explosion-proof standards such as ISO/IEC 80079-20-2. ensuring production equipment meets "Class e Increased Safety" protection requirements (matching IEC 61241-2 standard).
2. Metal Powder Processing Industry: Testing the MIT of metal dusts such as aluminum powder, zinc powder, and magnesium powder: Assessing ignition risks in powder production/storage processes, guiding the selection of dust removal systems and anti-static equipment; Meeting the testing requirements for the thermal safety performance of powder materials in ASTM E1491 standard.
3. Food Processing Industry: Testing the MIT of edible dusts such as flour, sugar powder, milk powder, and tea powder: Investigating dust explosion hazards in baking and sugar-making workshops, developing safe production procedures; Compliance with safety acceptance standards for food production enterprises (e.g., risk classification of workshop dust environments). 4. Light Industry/Building Materials: Test MIT (Mutual Aspect Ratio) for wood chips, tobacco dust, and plant fiber dust; guide the parameter setting of dust removal equipment in furniture and tobacco factories; match the dust environment safety assessment around "Electrical Equipment with Non-metallic Exterior Coverings" in EN 50281-2-1 standard.
5. Mining/Energy: Test MIT for coal dust and coke dust; evaluate the effectiveness of ventilation/cooling measures in coal mines and coal chemical workshops; provide dust ignition risk data for the layout of explosion-proof electrical equipment.
6. New Materials R&D: Test MIT for new 3D printing powders and battery material powders; clarify the dust safety performance of new materials in advance to avoid safety accidents during the R&D/trial production stage.
Standards
ASTM E1491-06:Standard Test Method for Thermal Performance of Powder Coatings Using Differential Scanning Calorimetry (DSC)
EN 50281-2-1:Cable Trunking Systems and Cable Ducting Systems for Electrical Installations - Part 2-1: Specific Requirements for Cable Trunking Systems and Cable Ducting Systems with a Non-Metallic Outer Covering - Coated or Uncoated
IEC 61241-2:Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Requirements for Protection Level "e" (Increased Safety)
ISO/IEC 80079-20-2:Explosive Atmospheres - Part 20-2: Material Characteristics for Gas and Dust Atmospheres - Test Methods for Determining the Minimum Ignition Energy (MIE) of Dust Clouds
Features
1) Built-in internationally used testing standards, allowing testing according to standard parameters or custom parameters.
2) Employs fuzzy PID temperature control algorithm for high-precision temperature control.
3) Features a temperature sensor calibration interface for easy calibration and correction.
4) Uses a Gauder-Grunwald furnace with a built-in quartz tube to ensure reliable furnace operation.
5) The furnace cavity material is made of heat-insulating vacuum ceramic fiber, providing excellent thermal insulation.
6) Thermocouples are from international brands, ensuring long-term stable operation.
7) Includes ambient temperature and humidity detection, automatically recording experimental environment information.
8) Remote control ensures personnel safety.
9) Hierarchical user management allows for different levels of account management and control.
10) Plug-and-play USB interface for convenient data management.
11) Professional industrial design, simple and elegant.
12) 7-inch color LCD touchscreen dynamically displays the experimental progress.
Technical Parameters
|
Operating environment |
(5 to 45)°C, <85% RH |
|
Temperature range |
Room temperature to 1000°C |
|
Rising time |
≤20min (room temperature to 500°C) |
|
Temperature control stability |
±5.0°C |
|
Temperature measurement accuracy |
±3.0°C |
|
Temperature measurement precision |
±0.1°C |
|
Powder spray pressure range |
(0 to 100)kPa |
|
Pressure accuracy |
±5% |
|
Storage volume |
500mL |
|
Ambient temperature measurement range |
(-10 to 60)°C |
|
Ambient humidity measurement range |
(5 to 95)% RH |
|
Interface |
USB*2 |
|
Power |
220VAC/50Hz |
|
Power |
2600W |
|
Dimensions |
670mm х 400mm х 590mm |
Accessoriess
1. Core Component: ZR-FCY-8A Dust Cloud Minimum Ignition Temperature Tester - Heating Furnace: Quartz tube (controllable from room temperature to 1000℃), temperature control accuracy ±1% (above 500℃) or ±3% (below 300℃).
2. Dust Spraying System: Compressed air drives dust diffusion, pressure range 0~1 bar.
3. Safety Protection: Wireless remote control operation, audible and visual alarms, mirror-reflective observation window, etc.
Test Procedures
1. Initial conditions: Furnace temperature set at 500℃, dust mass 0.1g, powder spraying pressure 10kPa.
2. Heating/cooling: Before ignition, increase the temperature to 700℃ in 50℃ increments.
3. After ignition, decrease the temperature to 300℃ in 20℃ increments, then decrease to a point where ignition ceases in 10℃ increments.
4. Data correction: According to IEC standards, the actual MIT (Mutual Achievement Test) should be 20℃ lower than the test value (if the test value > 300℃).
在线联系供应商
Other supplier products
| Falling Sand Abrasion Tester | Standards GB811-2022. GB24429 GB/T 38305 GJB1564A GA/T44. GA293 GA294 GA295 GA296 ASTMD968 ASTMD333 ASTMD1395 ASTMD2205 Main applicati... | |
| Standard Illumination Sample Stage | Standards ISO 3664:2009: Meets international standards for graphic arts and photography view conditions. DIN 6173-2: European norm for illuminant... | |
| Suture Needle Cutting Force Tester | The Suture Needle Cutting Force Tester is a precision instrument specifically used to detect the force required by medical suture needles during th... | |
| Resistance Tester for Molten Metal Droplet (Splash) Impact Performance | Performance and Standards: This resistance tester for molten metal droplet (splash) impact performance is developed in accordance with testing sta... | |
| High-Speed Screening Calorimeter | Product Introduction: The rapid - screening calorimeter is a professional calorimetric instrument for the quick assessment of reaction thermal haz... |
Same products
| Air Permeability Tester STD- F8 | 卖方: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | 卖方: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | 卖方: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | 卖方: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | 卖方: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |