ASTM F2100 mask tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
G506 Automatic Filter Performance Tester is used fortestingprofessional filter material and filtration efficiencyof a wide range of air filters including HEPA and ULPA filter, respirator, filter cartridge and protective clothing test. It also can use salt or oil mist to test filter media. Rapid acquisition of filter media performance evaluation parameters, and accurate evaluation of filter material quality, performance, life and so on. It is convenientto userforacademic research and product developmentof new filter materials, product quality control, material performance verification.
Standards
ASTM F2100:Standard Specification for Performance of Materials Used in Medical Face Masks
EN149:Respiratory protective devices - Filtering half masks to protect against particles - Requirements, testing, marking
NIOSH-42 CFR84:NIOSH Guide to the Selection and Use of Particulate Respirators(或 42 CFR Part 84 - Approval of Respiratory Protective Devices)
Parameters
| Items | Parameter |
| Apllication | Load and quality control |
| Max Efficiency | 99.999% |
| Aerosol Type | DOP/PAO/DEHS/Paraffi/Others Oil Aerosol、Salt |
| Aerosol Generation | Atomizing |
| CMD | 0.2μm(Oil)or 0.75um(NaCl) |
| GSD | <1.6(Oil)or <1.86(NaCl) |
| Flow Rate | 15-100L/min |
| Resistance | 0-150mm H2O(0-1470Pa) |
| Particle Detect | Scatter Photometer |
| Measurement Time | 10 Sec. |
| Data Report | LCD,RS-232 |
| Operation | Independent tewster、automatic production line |
| Standard compliant | US 42 CFR part 84.EN 143.JMOL,ISO 23328-1 ISO 16900-3 |
| Power Supply | 115VAC、60Hz,10A或230VAC,50Hz,5A |
| Compressor Air | 80psig,7scfm(550kPa,198std.L/min) |
| Dimension | 70cm x 70cm x 147cm(28in, x 28in.x 58in.) |
Accessoriess
Main Unit: As the core component of the testing instrument, it is responsible for overall control and data processing.
Aerosol Generator: Includes salt particulate aerosol generators and oil particulate aerosol generators, used to generate the aerosol particles required for the test.
Classifier: Utilizes the principle of inertia to collect unwanted large particles into a collection bottle, ensuring that the aerosol particles entering the testing system meet the requirements.
Particle Counter: Usually equipped with two units, used to measure the number or mass concentration of aerosols upstream and downstream of the filter media, and is a key device for calculating filtration efficiency. Some systems may use a laser scattering photometer instead of a particle counter.
Static Neutralization Device: Neutralizes the static electricity carried by the aerosols, reducing particle loss and the influence of static electricity on the test results.
Differential Pressure Sensor: Monitors the pressure drop across the filter media, assessing changes in resistance during the filtration process.
Flow Meter: Monitors the flow rate during the test, ensuring consistency of test conditions. Flow meters are typically 2.5 grade accurate, ranging from 10-100 L/min.
Vacuum pump: Provides the necessary negative pressure environment to ensure aerosol particles can smoothly enter the testing system.
Pneumatic clamps and protective devices: Employ pneumatic clamping, offering convenient operation and high safety, while also featuring protective devices to ensure safe use.
Programmable logic controller (PLC) and touchscreen: Enables automated control of the testing process, including control, monitoring, calculation, and data display functions. Some devices utilize a PLC control system and are equipped with a 7-inch color touchscreen.
Instruction manual and power cord: Provides an operation guide and power connection instructions to ensure users can correctly operate the equipment.
在线联系供应商
Other supplier products
| Micro Controll Four-ball Friction Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The microcomputer-controlled four-ball friction testing machine uses a sliding friction met... | |
| Combined Salt Spray Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This chamber is widely used in industries and laboratories to assess corrosion... | |
| Horizontal Fire Resistance Test Furnace for Building Elements,ISO 834 horizontal fire resistance test furnace for building elements | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Horizontal Fire Resistance Test Furnace for Building Elements is designed for fire resi... | |
| Advanced suture needle cutting force apparatus | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YY/T 0043-2016:Medical suture needle YY 0166-2002:Surgical suture needles with ... | |
| OEM Temperature and Humidity Alternating Test Chamber for Automotive Wires | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com TheTemperature and Humidity Alternating Test Chamber for Automotive Wiresis d... |
Same products
| Filter Efficiency Testing Equipment | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFilter Efficiency Testing Equipmentis ... | |
| G506 Filter Performance Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM F2100:Standard Specificat... | |
| Automated Filter Integrity Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Testing Standards ASTM F838 – Memb... | |
| High Efficiency Oil Water Separation Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Meth... | |
| DIN 51524 hydraulic oil analyzer | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards You can operate this unit in c... |