DIN 51524 hydraulic oil analyzer
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
You can operate this unit in compliance with the following standards:
(1) GB/T 18854-2015 – Hydraulic transmission: Determination of solid particle contamination levels in hydraulic oil;
(2) GB/T 14039-2002 – Hydraulic transmission: Oil contamination control and monitoring;
(3) GB/T 4207-2012 – Determination of water content in mineral-based lubricating oils;
(4) ISO 4406:2017 – Hydraulic fluid power: Coding of solid particle contamination levels;
(5) ISO 4407:2002 – Hydraulic fluid power: Particle counting method for contamination measurement;
(6) ISO 9110:1990 – Hydraulic fluid power: Filter performance test methods.
Parameters
| Parameter | Unit | Value |
|---|---|---|
| Rated Flow | L/min | 40 / 100 / 150 |
| Rated Pressure | MPa | 0.6 |
| Initial Pressure Loss | MPa | ≤ 0.2 |
| Coarse Filter Precision | μm | 100 |
| First-Stage Filter Precision | μm | 25 / 40 |
| Second-Stage Filter Precision | μm | 3 / 5 / 10 |
| Motor Power | kW | 1.1 + 0.75 / 2.2 + 1.1 / 4 + 1.1 |
| Power Supply | V | AC 380 |
Features
Dual-motor driven gear pump ensures smooth operation, low noise, strong self-priming, and stable performance.
High-pressure piping is equipped with overflow protection to prevent overpressure operation.
Thermal relay protection prevents motor overload and damage.
Suction inlet equipped with a coarse filter protects the pump and extends the life of precision filters.
Two-stage precision filtration rapidly improves oil cleanliness.
Filter precision is selectable to meet different operating conditions.
Integrated panel pressure gauges allow real-time monitoring of system status and filter contamination.
Accessories
(1) Dedicated Gear Pump – Dual pump configuration for stable flow.
(2) Coarse Filter – 100 μm.
(3) First-Stage Precision Filter – 25 μm / 40 μm.
(4) Second-Stage Precision Filter – 3 μm / 5 μm / 10 μm.
(5) Motor – Dual-motor drive.
(6) Pressure Gauge – System pressure monitoring.
(7) Overflow Valve – Overpressure protection.
(8) Heating System – Independent heating module for low-temperature operation.
(9) Consumable Filter Elements – Replaceable as needed.
Test Procedures
Ensure oil hoses are connected correctly and inlet/outlet valves are open.
Check power supply, motor status, and protection devices.
In low-temperature environments, start the heating system to bring oil to the required viscosity before operation.
Monitor pressure gauges during operation to avoid overpressure.
Replace filter elements promptly if the differential pressure rises significantly.
Before shutdown, close the inlet valve, depressurize the system, and then cut off the power.
Maintenance Information
Regularly inspect hoses, filter elements, and protection devices for wear or damage.
Replace filter elements according to operating hours or differential pressure readings.
Clean the system periodically to prevent sediment buildup.
Verify operation of the heating system and overflow protection before each use.
Record operation data to monitor system performance over time.
在线联系供应商
Other supplier products
| Photovoltaic module outdoor exposure test system | The Photovoltaic Module Outdoor Exposure Test System is designed to simulate real-world environmental conditions for accelerated aging and performa... | |
| Steel wheel wear testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Meet the standard: GB/T3810.7-2016 "Wear resistance test method for unglazed brick" ISO/D... | |
| Paper Roughness and Air Permeability Tester ,Bendtsen Roughness & Air Permeability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheTMI Paper Roughness and Air Permeability Testeris a versatile laboratory instrument desi... | |
| Wet leakage current test system of photovoltaic module | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and... | |
| PV-Panels Testing Devices | Features and Benefits 1. The capacity and performance of the workroom can be adjusted according to the size of the photovoltaic panel and your nee... |
Same products
| Automated Filter Integrity Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Testing Standards ASTM F838 – Memb... | |
| High Efficiency Oil Water Separation Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Meth... | |
| DIN 51524 hydraulic oil analyzer | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards You can operate this unit in c... | |
| Cartridge filter pore size distribution tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 2942:2004 — Hydrauli... | |
| Cartridge Dynamic Cycle Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ISO 23840 — Hydrauli... |















