ISO 12103 Cleanable Filter Media Test System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system complies with:

(1) VDI 3926-2 – Test guideline for cleanable filter media.

(2) ASTM D6830-02 – Laboratory scale air filter test method.

(3) ISO 12103-1 – Standard test dust for filter efficiency evaluation.

(4) ISO 5011 – Air filter testing for engines and machinery.

Parameters

ParameterUnitValue
Test Flow Rate m³/h 2 … 64
Differential Pressure Measuring Range Pa
Duration of Pressure Pulse ms 50 … 150
Pressure Tank Capacity bar 2 … 6
Test Specimen Dimensions mm Diameter ≤ 150
Power Supply 3 × 400 VAC, 16 A
Operating Medium (Aerosol) Pural-NF, Pural-SB, DEHS
Sensors Temperature, relative humidity
System Dimensions (W × H × D) mm 2800 × 1500 × 800
Weight kg approx. 120

Features

Standardised Filter Testing: Supports alumina oxide aerosols (Pural NF, Pural SB).

Automated Operation: Up to 14 hours of unattended testing.

Multi-Aerosol Capability: Solid and droplet aerosols supported.

Flexible Design: Rapid modification for future tests and additional features.

Operator-Friendly Control: Intuitive software interface for setup, monitoring, and data logging.

Compact Laboratory Use: Lightweight and portable, suitable for small-scale testing.

Accessories

AccessoryDescription
Atomizer Aerosol Generator Generates fine aerosol for filtration testing
Solid Materials Disperser Produces solid aerosol particles for standardised tests
Aerosol Dilution System Dilutes aerosols to desired concentration
Aerosol Spectrometer Measures particle size distribution and filtration efficiency

Test Principle

The system draws controlled airflow through filter media while applying standardized aerosol particles (solid or droplet). Differential pressure, fractional efficiency, and dust loading are continuously measured. Data acquisition provides detailed insight into the filtration performance and operational characteristics of the media under laboratory conditions.

Operation Instructions

Safety:

Ensure electrical connections are properly installed.

Maintain laboratory ventilation when using aerosols.

Operators should wear gloves and safety goggles during aerosol handling.

Setup:

Mount the filter media securely on the test platform.

Select aerosol type and configure airflow and pressure pulse parameters.

Verify sensors and calibration before starting the test.

Testing:

Start automated test sequence.

System injects aerosol, measures differential pressure, and records filtration efficiency and dust loading.

Data is logged automatically for analysis.

Post-Test:

Review differential pressure curves, fractional efficiency, and dust loading capacity.

Export reports for quality control and research documentation.

Maintenance Information

Regularly clean aerosol generators and dispersers.

Calibrate pressure sensors periodically.

Inspect control software and data acquisition systems for updates.

Maintain system cleanliness to prevent contamination.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Minimum Ignition Temperature (MIT) – Dust Cloud Tester
Minimum Ignition Temperature (MIT) – Dust Cloud Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Description Dust Cloud Minimum Ignition Temperature Tester is mainly used to assess the ex...
Compression Tester STD-FB3-A,ASTM D903 compression resistance verification machine
Compression Tester STD-FB3-A,ASTM D903 compression resistance verification machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The Compression Tester STD-FB3-A is a professional instrument designed for quantitative eva...
Athletic Footwear Shock Attenuating Tester
Athletic Footwear Shock Attenuating Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard SATRA TM142 ASTM F1614 ASTM F1976 Product Advantages 1. Uncompromising Precis...
Electric Spring Fatigue Furniture Testing Machine
Electric Spring Fatigue Furniture Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The King Size Foam Fatigue Tester is a single-station pneumatic fatigue testing system desi...
Automatic suture needle penetration and bending strength apparatus
Automatic suture needle penetration and bending strength apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Quality Control for Manufacturing Enterprises: During the production of sutur...
供应产品

Same products

ISO 29463 HEPA/ULPA filter performance testing System
ISO 29463 HEPA/ULPA filter performance testing System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli...
High-Precision ISO 16890 Filter Media Test Rig for R&D and QC
High-Precision ISO 16890 Filter Media Test Rig for R&D and QC 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com...
ISO 12103 Cleanable Filter Media Test System
ISO 12103 Cleanable Filter Media Test System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)...
Advanced Vehicle and Aircraft Air Intake Filter Test System
Advanced Vehicle and Aircraft Air Intake Filter Test System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)...
EN 779 Turbine Filter Test System
EN 779 Turbine Filter Test System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)...