Ductile Iron Foot Valve Flange End
A ductile iron foot valveis a kind of energy-saving valve. It is generally installed at the bottom end of the underwater suction pipe of the water pump to restrict the liquid in the water pump pipe from returning to the water source. It is not easy to be blocked and is mainly used in pumping pipelines, water channels, and supports. Single disc, double-disc, and multi-disc. There are flanged type and threaded type foot valve
Ductal Iron Foot Valve Flange End Dimensions
|
PN16 |
|||||||
|
DN |
D |
D1 |
D2 |
H |
b |
f |
Z-d |
|
DN40 |
150 |
110 |
84 |
148 |
18 |
3 |
4-19 |
|
DN50 |
165 |
125 |
99 |
166 |
20 |
3 |
4-19 |
|
DN65 |
185 |
145 |
118 |
201 |
20 |
3 |
4-19 |
|
DN80 |
200 |
160 |
132 |
221 |
22 |
3 |
8-19 |
|
DN100 |
220 |
180 |
156 |
265 |
24 |
3 |
8-19 |
|
DN125 |
250 |
210 |
184 |
300 |
26 |
3 |
8-19 |
|
DN150 |
285 |
240 |
211 |
360 |
26 |
3 |
8-23 |
|
DN200 |
340 |
295 |
266 |
470 |
30 |
3 |
12-23 |
|
DN250 |
405 |
355 |
319 |
568 |
32 |
3 |
12-28 |
|
DN300 |
460 |
410 |
370 |
653 |
32 |
4 |
12-28 |
|
150LBS |
|||||||
|
DN |
D |
D1 |
D2 |
H |
b |
f |
Z-d |
|
DN40 |
127 |
73 |
148 |
15 |
2 |
4-19 |
|
|
DN50 |
152 |
92 |
166 |
16 |
2 |
4-19 |
|
|
DN65 |
178 |
105 |
201 |
18 |
2 |
4-19 |
|
|
DN80 |
191 |
127 |
221 |
19 |
2 |
4-19 |
|
|
DN100 |
229 |
157 |
265 |
24 |
2 |
8-19 |
|
|
DN125 |
254 |
216 |
186 |
300 |
24 |
2 |
8-22 |
|
DN150 |
279 |
216 |
360 |
26 |
2 |
8-22 |
|
|
DN200 |
343 |
270 |
470 |
29 |
2 |
8-22 |
|
|
DN250 |
406 |
362 |
324 |
568 |
31 |
2 |
12-25 |
|
DN300 |
483 |
432 |
381 |
653 |
32 |
2 |
12-25 |
Foot Valve Flange End VS Threaded End
Both foot valvesflange end and threaded end foot valves standard are ASME, DIN, BS
Both foot valves flange end and threaded end foot valvesstandard are Class125/150, PN10/16
Stardard: ANSI CLASS 125/150, DIN 3202 PN10/16
Length: ANSI CLASS 125/150, DIN 3202 F1
Connection flange type: Flange end
The foot valve flange end shall be installed on the bottom flange of the underwater suction pipe of the water pump with bolts, and the threaded end foot valve shall be connected with the thread.
Ductal Iron Foot Valve Flange End FAQs
Which Direction Should Foot Valves Be Installed?
Foot valves must be installed in the vertical position.
Can Foot Valves Be Used for Gas?
No, foot valves can be used for water service only.
在线联系供应商
Other supplier products
| ZHRIB-D1 DIN 3202 BALL TYPE Check Valves Flanged End | The flanged ball check valve is used as a flap with a rubber foreskin ball. Under the action of the medium, it can be rolled up and down on the int... | |
| Flanges | Flanges Industrial ansi flanges for saleare a part used for connections between the ends of tubes or used at the entrance and exit of equipment fo... | |
| 45° Elbow Black Paint Seamless Buttweld | 45° seamless elboware pipe fittings and pipeline connections. Used in main trunk line and the branch pipe. For changing the direction of the pi... | |
| Check Valve With Single Disc | The single-disc check valve is also called a single plate check valve, a wafer check valve: it is a valve that can automatically prevent fluid from... | |
| Foot Valves | Foot valve is used in a variety of applications, it is a simple product to use and install but are a key component to your pump, they make a big im... |