AD3000-TPA Infant Resuscitator
With safe, precise and controllable PIP (Peak Inspiratory Pressure) and PEEP (Positive End Expiratory Pressure), Pigeon Medical Infant Resuscitators are easy to operate and can provide temporaty breathing support. It is crucial for NICU units, Nurseries, Delivery and Transport System.
Working Principle of Infant Resuscitator AD3000-TPA
Neonatal resuscitation also known as newborn cpap neonatal resuscitation is an emergency procedure focused on supporting the approximately 10% of newborn children who do not readily begin breathing, putting them at risk of irreversible organ injury and death. Through positive airway pressure, and in severe cases chest compressions, medical personnel can often stimulate neonates to begin breathing on their own, with attendant normalization of heart rate. CPAP infant resusciatator can deliver a more controlled and consistent peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP), which helps to protect the newborn's lungs.
Features of Infant Resuscitator AD3000-TPA
Consistent Care
The easy-to-use T-Piece circuit reduce variations in care, ensuring each breath is delivered in a similar manner.
Do More With Less
Powered by 5L/min, NeoPIP requires less gas flow to operate, for less gas consumed and improved transport range.
Durable & Dependable
Each NeoPIP unit is built to last; a solid case and metal fittings resist damage leading to long service life.
Specification of Infant Resuscitator AD3000-TPA
Model |
AD3000-TPA |
Pressure gauge |
-2-10kPa(-20-100cmH2O) |
PIP |
@5 LPM,2-27 cmH2O |
@8 LPM,4-36 cmH2O |
|
@10 LPM,6-42 cmH2O |
|
@15 LPM,12-57 cmH2O |
|
CPCP/PEEP |
@5 LPM,0.3-6 cmH2O |
@8 LPM,0.8-14 cmH2O |
|
@10 LPM,1-17 cmH2O |
|
@15 LPM,2.5-23 cmH2O |
|
Noise |
≤50dB(A) |
Gas source |
|
Recommended patient weightUp to 10KG |
|
Practical Application of Infant Resuscitator AD3000-TPA
Failure to breathe,including antepartum mechanism, recent intrapartum asphyxia, central nervous system depression, maternal drug abuse etc.
Failure to expand the lungs, including airway obstruction, respiratory distress syndrome, malformations involving the respiratory tract.
在线联系供应商
Other supplier products
Ventilator Circuit Support Arm (Light Type) | Pigeon MedicalCircuit Support Arm (Light Type) hook can provide a secure connection for the Ventilator, CPAP and Anesthesia Machine breathing circu... | |
NPWT Device/Suction Machine | In medicine, devices are sometimes necessary to create suction. Suction may be used to clear the airway of blood, saliva, vomit, or other secretion... | |
Infant Bed Manufacturer | Pigeon MedicalPN-1000A infant bed has a lower center of gravity, more mass, a broader base of support and can hold a larger baby than a bassinet. E... | |
AD3000-TPA Infant Resuscitator | With safe, precise and controllable PIP (Peak Inspiratory Pressure) and PEEP (Positive End Expiratory Pressure), Pigeon Infant Resuscitators are ea... | |
Trolley for Fabian Ventilators | We design this trolley to transport the fabian ventilator, Also we design a basket, the ventilator is placed in the basket, hospital ventilator equ... |
Same products
Grey Rubber Stopper For Blood Collection Tube | 卖方: Taizhou KangLong Medical Treatment Technology Co., Ltd. | Medical Grey Rubber Stopper For Blood Collection Tube Good formulation technology guarantees... | |
HTT-02 Hot Tack Tester | 卖方: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | 卖方: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | 卖方: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... | |
TST-01 Tensile Tester | 卖方: Cell Instruments Co., Ltd | TST-01 tensile testers are suitable for conducting a variety of tests, including tensile strength... |