CT/PT分析仪

1.1Application of GDVA-404 Current Transformer Tester

Testsforcurrenttransformer:

1)Excitationcurveandparameterstest

2)Turnsratiotest

3)Ratioandphaseerrortest

4)Polaritymarkcheck

5)Coilresistancemeasurement

6)Secondaryloopburdenmeasurement

7)ErrorlinecurvetestforprotectionCT

8)TransientCTparameterstest

9)CTnameplateguess

Testsforvoltagetransformer:

1)Excitationcurvetest

2)Turnsratiotest

3)Polaritytest

4)Secondaryburdentest

5)Coilresistancetest

Applicationsof GDVA-404Current Transformer Tester :

1)CTnameplatecheck

2)CTparameterscheckinworkburden

3)CTtransientparametersanalysis

4)CTratioandphaseerrorcalibration

5)PTroutinetest

1.2CTPTanalyzertechnicalindex

1Teststandards:IEC60044-1,IEC60044-6,GB1208,GB16847,C57.13

2Powersupply:AC220V±10%,50Hz/60Hz±10%

3Poweroutput:0.1~125V(AC)

4Currentoutput:0.001~5A(RMS)

5Poweroutput:300VA

6Currentmeasurement:

Range:0~10A(automaticallychangerangein0.1/0.4/2/10A)

Error<±0.1%+0.01%FS

7Voltagemeasurement:

Range:0~200V(automaticallychangerangein1V/10V/70V/200V)

Error<±0.1%+0.01%FS

8Turnsratiomeasurement:

Range:1~10000,

1~1000error<0.05%

1000~2000error<0.1%

2000~10000error<0.2%

9Phasemeasurement:error:±2min,resolution:0.01min

10Coilresistancemeasurement:

Range:0~8kΩ(automaticallychangerangein2ohm/20ohm/80ohm/800ohm/8kohm)

Error<0.1%+0.01%FS

Maximumresolution:0.1mΩ

11Temperaturemeasurement:-50~100Celsiusdegree,error<3Celsiusdegree

12CTSecondaryburden:

Range0~160ohm(automaticallychangerangein2ohm/20ohm/80ohm/160ohm)

Error<0.1%+0.01ohm

Maximumresolution0.001ohm

13PTSecondaryburden:

Range0~80kohm(automaticallychangerangein800ohm/8kohm/80kohm)

Error<0.2%+0.02%FS

Maximumresolution:0.1ohm

14Saveddatagroups:>1000groups

15Workcondition:Temperature:-10°C~50°C,moist:≤90%

16Size:485mm×356mm×183mm

17Weight:<13Kg


在线联系供应商

至: 重庆格纳迪机电设备有限公司
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

GD-4508C 沥青延伸度试验器
GD-4508C 沥青延伸度试验器 本仪器是根据中华人民共和国标准GB/T 4508-2010《石油沥青延度测定法》、中华人民共和国行业标准JTG E20-2011《公路工程沥青及沥青混合料试验规程》中的T 0605-2011《沥青延度试验》规定的要求设计的,适用于按GB/T 4508-2010、或T 0605-2011标准所规...
克利夫兰开口闪点测定仪
克利夫兰开口闪点测定仪 Reference Standard: 1. Cleveland Open Cup Methods for Flash and Fire Point of Petroleum Products 2. ASTM D92 Standard Test Method for Flas...
苯胺点测试仪
苯胺点测试仪 Purpose GD-262 Aniline Point Measuring Instrument is designed and made as per the National Standard GB/T262 “Test Methods for Aniline Point o...
GDE-1C 沥青恩格拉粘度计(数显)
GDE-1C 沥青恩格拉粘度计(数显) 本仪器是按照中华人民共和国行业标准JTG E20-2011《公路工程沥青及沥青混合料试验规程》中的T0622-1993《沥青恩格拉粘度试验(恩格拉粘度计法)》、中华人民共和国标准GB/T 266《石油产品恩氏粘度测定法》及上海市企业标准Q/YXYY11《WNE-1A型恩氏粘度计》规定的要求制造...
初次电流注入测试仪
初次电流注入测试仪 I.Summary: SLQ Primary Current Injection Testerisasortofspecialequipmentdesignedandmanufacturedforexperimentationofelectricsofpowerbusinessaswellas...
供应产品

Same products

Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 卖方: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...
Surface Performance Tester STD-FB4 - A
Surface Performance Tester STD-FB4 - A 卖方: Standard International Group (HK) Limited Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti...
Compression Tester STD - FB3 - A
Compression Tester STD - FB3 - A 卖方: Standard International Group (HK) Limited TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar...
Single - Strand Bending Tester STD - FB2 - SH
Single - Strand Bending Tester STD - FB2 - SH 卖方: Standard International Group (HK) Limited Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ...
Bending Tester STD- FB2 - S
Bending Tester STD- FB2 - S 卖方: Standard International Group (HK) Limited Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig...