CT/PT分析仪
Testsforcurrenttransformer:
1)Excitationcurveandparameterstest
2)Turnsratiotest
3)Ratioandphaseerrortest
4)Polaritymarkcheck
5)Coilresistancemeasurement
6)Secondaryloopburdenmeasurement
7)ErrorlinecurvetestforprotectionCT
8)TransientCTparameterstest
9)CTnameplateguess
Testsforvoltagetransformer:
1)Excitationcurvetest
2)Turnsratiotest
3)Polaritytest
4)Secondaryburdentest
5)Coilresistancetest
Applicationsof GDVA-404Current Transformer Tester :
1)CTnameplatecheck
2)CTparameterscheckinworkburden
3)CTtransientparametersanalysis
4)CTratioandphaseerrorcalibration
5)PTroutinetest
1.2CTPTanalyzertechnicalindex
1Teststandards:IEC60044-1,IEC60044-6,GB1208,GB16847,C57.13
2Powersupply:AC220V±10%,50Hz/60Hz±10%
3Poweroutput:0.1~125V(AC)
4Currentoutput:0.001~5A(RMS)
5Poweroutput:300VA
6Currentmeasurement:
Range:0~10A(automaticallychangerangein0.1/0.4/2/10A)
Error<±0.1%+0.01%FS
7Voltagemeasurement:
Range:0~200V(automaticallychangerangein1V/10V/70V/200V)
Error<±0.1%+0.01%FS
8Turnsratiomeasurement:
Range:1~10000,
1~1000error<0.05%
1000~2000error<0.1%
2000~10000error<0.2%
9Phasemeasurement:error:±2min,resolution:0.01min
10Coilresistancemeasurement:
Range:0~8kΩ(automaticallychangerangein2ohm/20ohm/80ohm/800ohm/8kohm)
Error<0.1%+0.01%FS
Maximumresolution:0.1mΩ
11Temperaturemeasurement:-50~100Celsiusdegree,error<3Celsiusdegree
12CTSecondaryburden:
Range0~160ohm(automaticallychangerangein2ohm/20ohm/80ohm/160ohm)
Error<0.1%+0.01ohm
Maximumresolution0.001ohm
13PTSecondaryburden:
Range0~80kohm(automaticallychangerangein800ohm/8kohm/80kohm)
Error<0.2%+0.02%FS
Maximumresolution:0.1ohm
14Saveddatagroups:>1000groups
15Workcondition:Temperature:-10°C~50°C,moist:≤90%
16Size:485mm×356mm×183mm
17Weight:<13Kg
在线联系供应商
Other supplier products
| GD-4508C 沥青延伸度试验器 | 本仪器是根据中华人民共和国标准GB/T 4508-2010《石油沥青延度测定法》、中华人民共和国行业标准JTG E20-2011《公路工程沥青及沥青混合料试验规程》中的T 0605-2011《沥青延度试验》规定的要求设计的,适用于按GB/T 4508-2010、或T 0605-2011标准所规... | |
| 克利夫兰开口闪点测定仪 | Reference Standard: 1. Cleveland Open Cup Methods for Flash and Fire Point of Petroleum Products 2. ASTM D92 Standard Test Method for Flas... | |
| 苯胺点测试仪 | Purpose GD-262 Aniline Point Measuring Instrument is designed and made as per the National Standard GB/T262 “Test Methods for Aniline Point o... | |
| GDE-1C 沥青恩格拉粘度计(数显) | 本仪器是按照中华人民共和国行业标准JTG E20-2011《公路工程沥青及沥青混合料试验规程》中的T0622-1993《沥青恩格拉粘度试验(恩格拉粘度计法)》、中华人民共和国标准GB/T 266《石油产品恩氏粘度测定法》及上海市企业标准Q/YXYY11《WNE-1A型恩氏粘度计》规定的要求制造... | |
| 初次电流注入测试仪 | I.Summary: SLQ Primary Current Injection Testerisasortofspecialequipmentdesignedandmanufacturedforexperimentationofelectricsofpowerbusinessaswellas... |
Same products
| Air Permeability Tester STD- F8 | 卖方: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | 卖方: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | 卖方: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | 卖方: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | 卖方: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |