Walsn Coriolis Mass Flowmeter(US SERIES)

Overview


Walsn Oxygen Analyzer is designed to measure the continuous oxygen concentration in combustion flue gases of boilers and furnaces. Walsn Oxygen Analyzer uses a non-sampling (wet) analysis method. It consists of detecting unit (oxygen probe) and control unit (transmitter).

The flue mounted probe has a thermostatically controlled heated Zirconia oxide sensor located at the flue end of the probe. The control unit is designed for use with the Zirconia sensor type oxygen probe.

The control unit offers a centralized termination for functions such as an automatic calibration box, external calibration contacts, status relay contacts and analog and serial outputs.


Virtually no maintenance is required. Repair can be carried out quickly and simply: the internal components can be withdrawn from the probe and replaced as one unit.


The probe will safely operate under start-up conditions for all conventional boiler fuels,provided the fuel ignition temperature is greater than 200°C/392°F.

Measuring Principle


Walsn Oxygen Analyzer contains a zirconia oxide sensing element, comprising a thimble-shaped zirconia cell fitted with inner and outer electrodes at its closed end.


The inner electrode is exposed to the flue gas entering the open end of the cell; the outer electrode is supplied with air from a pump or regulator and is therefore exposed to a constant partial pressure of oxygen.

Since zirconia is an electrolyte which conducts only oxygen ions at temperatures in excess of 600°C/1112°F, the voltage generated between electrodes (i.e. the cell output) is a function of the ratio of the oxygen partial pressure on the inner electrode and its temperature. Therefore, any change in the oxygen partial pressure of the flue gas at the exposed electrode produces a change in the cell output voltage as dictated by the Nernst equation.

Measuring System


Walsn Oxygen Analyzer consists of a detecting unit (oxygen probe) and a control unit (transmitter)

Integral version: The detecting unit and the control unit form a single mechanical unit.

Model: OAM-800 (The user interface includes a four-character display, a set of condition indicator LEDs and a tactile keyboard with cursor controls)

Remote version: The detecting unit is mounted separate from the control unit.

Model: OAM-800-R

Detecting unit: WOR800RD

Control unit: WOR800RA (The user interface includes a four-character display, a set of condition indicator LEDs and a tactile keyboard with cursor controls)

Features


1) Single point, straight plug sensor which can achieve a quick, accurate and reliable measurement, measurement accuracy within the 1% range.
2) Field replacement, easy daily maintenance.
3) Output signal system complies with a user’s on-site monitoring requirements, and can be connected to any process control equipment.
4) Automatic calibration.
5) Power consumption gives longer longevity.
6) Use platinum to lead a derived analog signal.
7) Zirconium cell diagnosis function, which can check Zirconium cell operation statuses, as well as prompt fault alarm information.
8) The Zirconium cell boasts a nanoscale coating technology, and platinum welding process to ensure an air tight seal, durable working life and high measurement accuracy.
9) Built-in heaters ensure a stable working temperature of the Zirconium cell resulting in longer working life.

Input


1) Application fields.
2) Boiler type (Tangential-fired Boiler/ Wall-fired Boiler/W-flame Boiler/CFB).
3) Flue thickness.
4) Type of fuel (fuel oil/fuel coal/gas).
5) Sulfur content in fuels.
6) Flue gas temperature.
7) The flue gas dust concentration.
8) Flue gas humidity.

Output

Analogue outputs:Single channel isolated 0 to 10 mA; 0 to 20 mA; 2 mA to 20 mA; 4 to 20mA menu selectable.

Parameters:


O2 concentration
Calibration gas
Cell temperature
Fault messages
Cell/Thermocouple Information

Serial output:RS485 Modbus protocol

Fault indication:LED indication and error codes


在线联系供应商

至: Walsn Enterprises Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Walsn Coriolis Mass Flowmeter(US SERIES)
Walsn Coriolis Mass Flowmeter(US SERIES) Overview Walsn Oxygen Analyzer is designed to measure the continuous oxygen concentration in combustion flue gases of boilers and furnaces. Wal...
Walsn Coriolis Mass Flowmeter(US SERIES)
Walsn Coriolis Mass Flowmeter(US SERIES) Magnetic Coils 1) Current tracking technology ensures a highly stable magnetic field2) Real time coil excitation verification3) Coil geometry desi...
Walsn Coriolis Mass Flowmeter(US SERIES)
Walsn Coriolis Mass Flowmeter(US SERIES) Overview Walsn Flame Detection System is an essential detection system for coal fuel, gas, and oil Furnace Safeguard Supervisory System, which wid...
Walsn Coriolis Mass Flowmeter(TS SERIES)
Walsn Coriolis Mass Flowmeter(TS SERIES) Product Features1) Highly sensitive trapezoidal shape2) Closed loop controller on ASIC for improved response time and 2-phase flow performance3) Dy...
Walsn Coriolis Mass Flowmeter(US SERIES)
Walsn Coriolis Mass Flowmeter(US SERIES) Product Features1) Highly sensitive trapezoidal shape2) Closed loop controller on ASIC for improved response time and 2-phase flow performance3) Dy...
供应产品

Same products

PH-2398  pH/EC/ORP/温度 多参数测试仪
PH-2398 pH/EC/ORP/温度 多参数测试仪 卖方: 科立龙电子股份有限公司 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或...
ORP-2026S  防水型 土壤ORP&温度 二合一测试仪
ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 卖方: 科立龙电子股份有限公司 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
防水型 EC /TDS/温度三合一参数测试仪
防水型 EC /TDS/温度三合一参数测试仪 卖方: 科立龙电子股份有限公司 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ...
EC-98330 电导率营养测试棒
EC-98330 电导率营养测试棒 卖方: 科立龙电子股份有限公司 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0...
PH-808防水笔式土壤PH计
PH-808防水笔式土壤PH计 卖方: 科立龙电子股份有限公司 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保...