Hydraulic Oil Precision Filter Tester

1.Conformity standard:

GJB420. NAS1638. ISO4406. 18/16/13

2.Characteristics and Applications

2.1 Features of oil filter:

● Specialized gear pump set with low noise, strong self-priming ability and smooth operation.

● The high pressure pipeline is equipped with overflow protection device, which can effectively protect the safety of the hydraulic system.

● The coarse filter at the suction port protects the oil pump and extends the service life of the main filter.

● The fine filter can be selected with different precision according to the different needs of users to achieve the required results.

● The panel is equipped with a pressure gauge, which continuously indicates the operating condition of the system and the degree of contamination of the filter element during operation. There are differential pressure transmitters on the pre-filter and fine filter to indicate the system cartridge at any time.

2.2 Application of oil filtering machine:

Filtration of hydraulic lubrication system during refueling.

● Bypass filtration of hydraulic lubrication system during operation.

● Circulation filtration of hydraulic lubrication system before operation.

● Hydraulic lubrication system oil is not filtered and pumped out by the pump of the equipment itself.

(Note: This machine is not applicable to flammable and explosive media such as fuel oil.)

3. Technical Parameters:

Working Pressure: 0.6MPa

Differential Pressure for Alarm: 0.2MPa

Flow Rate: 50±5L/min

Medium: ≤160mm/s (20℃)

Accuracy: 5μm

Rated Power: 2.2KW

Power Supply Voltage: 3-phase 380V

Frequency: 50Hz

Operating temperature: 20 ℃ - 70 ℃

4. Cleaning and replacement of the filter:

When the oil filter works for a period of time, the oil filter oil system pressure increases accordingly, the performance of its components have different effects, especially on the filter precision of the filter element of the shadow

core damage, the main reason for this is that the filter element of the differential pressure rises, the need to replace the filter element. Specific cleaning and replacement methods are as follows:

4.1 Cleaning: (only on the pump before the suction oil filter)

4.1.1 Cleaning cycle: oil filter continuous work for a week (about 150 hours)

a. Unscrew the top cover of the oil suction filter and take out the filter element.

b.Cleaning the filter element:When cleaning the filter element, soak it with gasoline for about half an hour and then remove the impurities with a brush.

4.2 Replacement

4.2.1. Conditions for replacement: When the oil filter is filtering, when the red indicator pops up on the differential pressure alarm installed on the pre-filter and fine filter, the cartridge needs to be

4.2.2 Replacement method: loosen the four bolts on the upper cover of the pre-filter and fine filter, remove the upper cover, take out and replace the filter element.

5.Precautions

5.1 The oil filter can not filter gasoline and other flammable liquids.

5.2 If the oil pool (or tank) of the oil is too dirty and there may be large obstacles, in the suction port should be installed on the large mesh filter protection.

5.3 The oil suction and discharge pipes should be kept clean.


在线联系供应商

至: 标准集团
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Protective clothing flame spread tester  ISO 15025
Protective clothing flame spread tester ISO 15025 Applications: The instrument is applied for thetesting of fire hazard using com-bustible materials, like fabric orother similar functional materia...
Paper whiteness tester
Paper whiteness tester Paper whiteness tester - Other test instrument - standard Product Introduction: Paper whiteness tester is suitable for the whiteness measurement ...
Puncture Resistance Testing Machine for Goggles
Puncture Resistance Testing Machine for Goggles Puncture Resistance Testing Machine for Goggles - Flammability Testing equipment price quotation - standard Standards: ECE R22.05, EN1077 ...
Geotextile Opening Size Tester (Dry Sieving) ISO 8124-1 ISO 8124-4
Geotextile Opening Size Tester (Dry Sieving) ISO 8124-1 ISO 8124-4 Standards: ASTM 4751.GB/T 14799.JTG E50.T1144 SL/T 23.ISO 8124-1.ISO 8124-4 Applications: Geotextile Opening Size Tester (Dry Sieving), to deter...
KES - FB1 - A Tensile and Shear Tester
KES - FB1 - A Tensile and Shear Tester Content The Tensile and Shear Tester analyzes hand movements-referred to as “tensile” and “shear”-performed by artisans ...
供应产品

Same products

PH-2398  pH/EC/ORP/温度 多参数测试仪
PH-2398 pH/EC/ORP/温度 多参数测试仪 卖方: 科立龙电子股份有限公司 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或...
ORP-2026S  防水型 土壤ORP&温度 二合一测试仪
ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 卖方: 科立龙电子股份有限公司 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
防水型 EC /TDS/温度三合一参数测试仪
防水型 EC /TDS/温度三合一参数测试仪 卖方: 科立龙电子股份有限公司 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ...
EC-98330 电导率营养测试棒
EC-98330 电导率营养测试棒 卖方: 科立龙电子股份有限公司 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0...
PH-808防水笔式土壤PH计
PH-808防水笔式土壤PH计 卖方: 科立龙电子股份有限公司 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保...