Mask BFE Testing Machine

Mask BFE Testing Machineis used to test the percentage of material containing bacterial suspended particles at a specific flow rate.
Features:
1. MaskBFE Testing Machine: negative pressure test system, can protect the safety of the operator.
2. Peristaltic pump built in the negative pressure cabinet,A, B channel 28.3L/min.
3. The flow rate of the peristaltic pump can be set.
4. BFE Tester atomization effect is good.

Mask BFE Testing Machinetest principle:
Bacterial filtration efficiency Tester consists of aerosol generation system, aerosol chamber and aerosol transmission device, negative pressure cabinet, 28.3 l/min carbon sampler and other components.The entire detector is controlled by the console.
The console adopts microcomputer control system to coordinate and control the work of aerosol generating system, transmission system, negative pressure cabinet and sampling system, and display the working status in real time.The entire measurement work is done automatically.

Applicable Standards
  • ASTM F2100 standard specification for performance of materials used in medical face masks
  • EN 14683standard that medical face masks in Europe are required to comply with
  • ASTM F2101 standard test method for evaluating bacterial filtration efficiency (BFE) of medical mask materials using Staphylococcus aureus biological aerosol
  • YY0469-2011Technical requirements for surgical mask
  • YY/T 0969-2013Single-use medical face mask

Technical Specification:
Conforms to EN 14683 and ASTM F2101
A Route Sampling Flow: 28.3L/min, resolution 0.1, E±2.O% L/min
B Route Sampling Flow: 28.3L/min, resolution 0.1, E±2.O% L/min
Spray Flow: (O.l e?? 10)L/min, resolution 0.1, E±5.O% L/min
Peristaltic Pump Flow: (0.001 ? 3.O)mL/min, resolution 0.001, E±2.O%
Negative Pressure Chamber: (-90 ? -120)Pa, resolution 0.1, E±I.O%
Working Temperature: OOC to 500C
High Efficiency Particulate Air Filter Properties:
Diameter of aerosol generator mass: Average diameter:
(3.0+0.3)fm; Geometric Standard Deviation<1.5pm
Double Routes 6-lever Andersen Sampling apparatus:
Level l: >7gm; Level Il: (4,7 to 7)gm; Level Ill: (3,3 to 4.7)gm;
Level IV: (2.1 to 3.3)gm; Level V: (1.1 to 2.1)gm;
Level VI: (0.6 to 1.1)gm
Total number of positive quality control sampler particles: (2200±500)cfu
Negative Chamber Flow Speed: 25m/min
Size of Aerosol Chamber: at least (600x80x3) mm
Power supply: 220 V AC, 60 1-Iz
Noise: 65db(A)

Characteristics of G299Mask BFE Testing Machine:

1. Intelligent touch screen control panel
more efficient and reliable, programmable 10 inch colorLCD touch, achieve control, data display and other functions
2. High precision
Two samplers simultaneously sampling, avoid the test errorby intermediate link, improve the accuracy of test
3. Multi directional protection design
Equipped with current overload protection, leakage protectionand negative pressure cabinet to ensure safety for operator
4. Stability customized parameters
Adopts imported accessories, features stable movements,accurate test data and good repeatability

Applications ofbacterial filtration efficiency tester:


Mask BFE Testing Machineis used to detect the filtration efficiency of masks, and also can be used for measurement and calibration departments, scientific research institutions, mask production enterprises and other relevant departments.


在线联系供应商

至: 标准集团
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

TABER 5750 Abrasion Tester
TABER 5750 Abrasion Tester Standards: ASTM D3884 、 ASTM D1175 、 ASTM D1044 、 ASTM D4060 、 TAPPI T476 、 ISO 9352 、 ISO 5470-1 、 JIS K7204 、 JIS A1453、 JIS K6902 、 JIS L1096...
Anti Synthetic blood penetration tester
Anti Synthetic blood penetration tester Standards: GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood. YY/T 0691-2008 Clothin...
High temperature vacum friction & wear tester
High temperature vacum friction & wear tester Main uses: High temperature vacuum friction and wear testing machine is mainly used to study the friction and wear characteristics of materials in...
Aperture analyzer
Aperture analyzer The Aperture Analyzer is a precision instrument designed to measure and analyze the size, distribution, and shape of apertures (openings or pores) ...
Chrysler Flex Fold Tester
Chrysler Flex Fold Tester Standards: Chrysler LP 463 LB 9-01. Chrysler LP 463 KB 13-01. Chrysler LP 463 KB 10-01 Applications: The Chrysler Flex Fold Tester was designed ...
供应产品

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 卖方: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer 卖方: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester 卖方: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool 卖方: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester 卖方: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...