Double Plate Thermal Conductivity Apparatus

Double plate thermal conductivity tester integrated water bath thermostat equipment, all measurement and control are used computer control. Mainly testing plastic, rubber, glass, fiberboard, benzene board, extruded board, foam concrete, hollow glass, wood, all kinds of insulation materials such as homogeneous plate material, and can measure the pellets, bulk materials, soft materials and other Thermal conductivity of matter. The instrument can be widely used in heat and insulation materials production enterprises, the relevant quality inspection departments and units, institutions of higher learning and research institutes and other scientific research units.



Standards
GB/T 10294-2008 Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials
GB/T 3399-1982 Test method for thermal conductivity of plastics - Heat - resistant plate method
GB/T 10801.1-2002 Thermal insulation polystyrene foam
GB/T 10801.2-2002 Extruded polystyrene foam
GB/T 3139-2005 Test method for thermal conductivity of fiber reinforced plastics
GB/T 17794-2008 Flexible foam rubber and plastic insulation products



Features
Chassis is nice. Test box shell uses spray method. It has strong mechanical strength, anti-corrosion
The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.
High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.
Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.
Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.


Technical Parameters

Items Parameters
Specimen standard size 300mm × 300mm × H (5 ~ 40) mm
Specimen flatness 0.1mm
Thermal conductivity measurement display range (0.001 ~ 2.000) W / (m • K)
Thermal conductivity measurement accuracy ± 3%
Thermal conductivity measurement Repeatability ± 1%
Temperature resolution 0.01 ℃
Temperature control accuracy 0.05 ℃


Technical Parameters

Different types of thermal conductivity tester temperature measurement range Model Cold plate temperature control interface ℃ Hot plate temperature control range ℃
IMDRY3001-I Room temperature - 95 ℃ Room temperature - 100 ℃
IMDRY3001-Ⅱ -℃ -5 ℃ - 95 ℃ 15 ℃ - 95 ℃
IMDRY3001-Ⅲ -10 ℃ - 95 ℃ 10 ℃ - 95 ℃
IMDRY3001-IV -15 ℃ - 95 ℃ 5 ℃ - 95 ℃
IMDRY3001-V -20 ° C - 95 ° C 0 ° C - 95 ° C
IMDRY3001-Ⅵ -30 ℃ -95 ℃ -10 ℃ -95 ℃
IMDRY3001-VII -40 ℃- 95 ℃ -20 ℃ - 95 ℃
Power supply AC 220V ± 10%, 2.5KW
Specimen thickness Standard 25mm, range (5 ~ 40) mm
Specimen thermal resistance requirements the thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements.
Clamping force No more than 2.5kPa

在线联系供应商

至: 标准集团
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Femoral Stem Fatigue Performance Testing Machine
Femoral Stem Fatigue Performance Testing Machine Standard YY/T 0809.4 (China): Specifies fatigue testing protocols for femoral stems in partial/total hip arthroplasty. ISO 7206-4 (Internationa...
Particle Strength Tester
Particle Strength Tester Standard ASTM D4179: Standard Test Method for Single-Pellet Pressure Resistance of Catalysts and Catalyst Carriers ASTM D6175: Standard Test Me...
Respirator Fit Tester
Respirator Fit Tester Hydrostatic Head Tester - Textile and Apparel - standard Applications: Overall Mask Leakage Test: Mask leakage is measured while the mask is ch...
Anti Synthetic blood penetration tester ISO 22609  YY 0469-2011
Anti Synthetic blood penetration tester ISO 22609 YY 0469-2011 Standards: GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood. YY/T 0691-2008 Clothing ...
Static pressure and puncture testing machine safety shoes
Static pressure and puncture testing machine safety shoes Test purpose: Measure the compression resistance of the shoe head cover and the puncture resistance of the steel plate to prevent the operator fro...
供应产品

Same products

Large Naïve VHH Library
Large Naïve VHH Library 卖方: AlpVHHs Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o...
PH-2398  pH/EC/ORP/温度 多参数测试仪
PH-2398 pH/EC/ORP/温度 多参数测试仪 卖方: 科立龙电子股份有限公司 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或...
ORP-2026S  防水型 土壤ORP&温度 二合一测试仪
ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 卖方: 科立龙电子股份有限公司 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
防水型 EC /TDS/温度三合一参数测试仪
防水型 EC /TDS/温度三合一参数测试仪 卖方: 科立龙电子股份有限公司 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ...
EC-98330 电导率营养测试棒
EC-98330 电导率营养测试棒 卖方: 科立龙电子股份有限公司 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0...