Rupture strength tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Rupture Strength Tester is designed to evaluate the mechanical pressure resistance and rupture strength of photovoltaic module components under controlled pressurization conditions. The system applies uniform hydraulic or pneumatic pressure to determine the failure threshold of module glass, backsheets, and encapsulation structures, supporting safety qualification and structural reliability assessment of photovoltaic modules.
Application
(1) Rupture strength testing of photovoltaic module front glass
(2) Pressure resistance evaluation of PV module backsheets and encapsulants
(3) Safety verification of single-glass and dual-glass photovoltaic modules
(4) Mechanical integrity assessment under simulated wind and snow loads
(5) Quality control and type approval testing in PV module manufacturing
(6) Failure analysis and material comparison in PV R&D laboratories
Standards
(1) IEC 61730-2 – Photovoltaic (PV) Module Safety Qualification – Requirements for Testing
(2) UL 61730 – Safety Standard for Photovoltaic Modules
(3) CE Certification (Conformité Européenne)
Features
(1) Wide Pressure Capability: Suitable for rupture testing of thin-film, crystalline silicon, and dual-glass PV modules.
(2) High-Resolution Pressure Control: Enables early detection of micro-cracking and progressive structural failure.
(3) Multi-Unit Measurement Interface: Supports kPa, psi, and kg/cm² for international testing requirements.
(4) Enhanced Safety Structure: Reinforced test chamber allows safe observation of specimen rupture.
(5) Automated Test Control: Preset pressure ramp and holding sequences reduce operator variability.
(6) Integrated Data Recording: Pressure–time curves and rupture values stored for traceability and analysis.
(7) Robust Construction: Stainless steel frame ensures long-term stability under repeated high-pressure operation.
Parameters
| Parameter | Specification |
|---|---|
| Pressure Range | 250–5,600 kPa (36–812 psi) |
| Pressure Resolution | 0.01 kg/cm² |
| Holding Pressure | 5 kg/cm² (adjustable) |
| Control Accuracy | ±1% FS (full scale) |
| Air Source Requirement | ≥6 kg/cm² (customer-provided) |
| Power Supply | 220V AC, 50/60Hz, single-phase |
| Dimensions | 560 mm (W) × 470 mm (D) × 550 mm (H) |
| Weight | 60 kg (net) |
Accessories
(1) Testing Fixtures: 1× specialized clamping fixture for 2–20 mm module thickness
(2) Membranes: 2× high-temperature rubber membranes (up to 300°C)
(3) Calibration Tools: 5× aluminum foil calibration discs
(4) Consumables: 85% glycerin solution for hydraulic calibration, disposable dust filters
(5) Safety Equipment: Safety goggles (ANSI Z87.1), emergency pressure release key
(6) Documentation: Multilingual quick-start guide and IEC/UL compliance certificates
Test Procedures
(1) Install the PV module specimen securely into the clamping fixture.
(2) Select pressure unit, ramp rate, and holding parameters via the touchscreen interface.
(3) Initiate pressurization and monitor real-time pressure increase.
(4) Maintain holding pressure as specified or continue ramping until rupture occurs.
(5) Record rupture pressure, pressure–time curve, and failure mode automatically.
Maintenance Information
(1) Inspect sealing membranes and clamping fixtures regularly for wear or deformation.
(2) Verify pressure sensor calibration at scheduled intervals.
(3) Clean the test chamber after each rupture test to remove debris.
(4) Check safety valves and electronic cut-off functions before routine operation.
(5) Store the tester in a clean, dry environment to maintain long-term accuracy.
在线联系供应商
Other supplier products
| Composite Material Thermal Cycling Wet Freezing Characterization System | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Thermal Cycle Wet Freezing Testing Machine is designed for comprehensive environmental ... | |
| Microbial Barrier Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Y/T 0471.5-2017 is a newly updated standard, which specifies the experimental method for ev... | |
| Oxygen Index Test Apparatus丨Oxygen Index Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com TestingStandards ISO4589-2.ASTMD2863.GB/T2406.GB/T5454 Applications ThisOxygen Index Tes... | |
| Computer-controlled High Precision Explosion-proof Capillary Rheometer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) HG/T 4300-2012 — Capillary Rheometer Test Method for Pla... | |
| Electric pencil hardness tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Electric Pencil Hardness Tester is designed to determine the surface hardness of coatin... |
Same products
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... | |
| EC-98330 电导率营养测试棒 | 卖方: 科立龙电子股份有限公司 | 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0... | |
| PH-808防水笔式土壤PH计 | 卖方: 科立龙电子股份有限公司 | 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保... |