Cleveland Open Cup Flash Point Tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The instrument can automatically test the flash point and ignition point of petroleum products (the ignition point of oil exceeding 80 ° C, except crude oil and petroleum fuel), and can be compared with the test results of manual instruments, very simple and convenient.

Meets the ISO 2592 standard. Its programmable logic controller and touch screen (5.5 ") help automate testing, and managing test results is easy.

Application

Covering Multiple Industries, Driving Safety and Efficiency Upgrades

Petrochemical Industry

Refining and Quality Inspection: Monitoring flash point changes in processes such as crude oil distillation and lubricant blending to ensure product quality. For example, a refinery reduced the lubricant rejection rate from 2% to 0.5% by real-time flash point detection.

Asphalt Production: Testing asphalt flash point to meet JTJ052 standards and prevent spontaneous combustion risks during transportation.

Power and Energy Sector

Transformer Oil Testing: Determining the flash point of transformer oil according to DL/T 596 standard to assess its insulation performance and aging degree. For example, a power plant found that the flash point of a transformer oil had dropped to 130℃ through testing, and timely replacement prevented equipment failure.

New Energy Research and Development: Studying the flash point characteristics of new fuels such as biodiesel and hydrogen carriers to promote the application of clean energy.

Transportation Industry

Railways and Aviation: Detecting the flash point of locomotive oil and aviation lubricants to ensure operational safety. For example, an airline found that the flash point of a batch of aviation fuel was too low through testing, and suspended the use of that batch of fuel to avoid flight accidents.

Standard

ASTM D92:Standard Test Method for Flash and Fire Points by Cleveland Open Cup

IP 36. 403:Determination of Flash and Fire Points by Cleveland Open Cup Method (IP 36/403)

ISO 2592:Determination of flash and fire points - Cleveland open cup method

AFNOR T60-118:Petroleum products - Determination of flash and fire points - Cleveland open cup method (AFNOR T60-118)

EN 22592:Petroleum products - Determination of flash and fire points - Cleveland open cup method (EN 22592)

DIN 51376:Testing of mineral oils; determination of flash and fire point by Cleveland open cup

Feature

Automates the testing process for both flash point and ignition point, reducing operator intervention and potential for error.

Provides highly repeatable and reproducible test results, crucial for reliable product characterization.

Designed to comply with the ISO 2592 standard (Cleveland Open Cup Method).

Features an intuitive 5.5-inch color touch screen and programmable logic controller (PLC) for easy operation and test management.

Simplifies data processing and result management, enhancing laboratory efficiency.

Offers a convenient and efficient alternative to traditional manual testing methods.

Equipped with safety features necessary for handling flammable petroleum products.

Product Features:

Automatic Test Procedure: Conducts the heating, test flame application, flash detection, and ignition point determination automatically.

Programmable Logic Controller (PLC): Enables precise control over the test parameters and sequences.

Touch Screen Interface (5.5"): Provides a user-friendly interface for setting up tests, monitoring progress, and viewing results.

Data Processing and Management: Capable of processing test data and facilitating easy management of results.

Micro Printer: For direct printing of test results for record-keeping.

Integrated Heating System: Precisely controls the sample temperature rise rate.

Automatic Ignition System: Applies the test flame at specified intervals.

Flash/Ignition Detection System: Reliably detects the flash and sustained ignition.

Parameters

DescriptionDetails
Dimensions 550(W) x 400(D) x 320(H)mm
Table size 1000(W) x 600(D) x 800(H)mm (assuming the "1.000" is a typo and should be "1000")
Power supply AC 220V 50/60Hz, 15A
Weight 30kg
Instruction manual Available
Exhaust Minimum 50L/s
Tools Propane gas, vacuum cleaner

Accessoriess

Thermal fuse

Gas hose

Heating plate

AC power cord

Instruction manuals, etc.

Test Procedures

Sample Preparation: Heat the sample until it becomes fluid, then pour it into the cup up to the marked line, avoiding contamination of the cup walls.

Heating Control: In the initial stage, heat rapidly at 14-17℃/min, then slow down when the temperature reaches 56℃ below the expected flash point.

Critical Stage: When the temperature is 28℃ below the expected flash point, control the heating rate to 5.5℃/min ± 0.5℃.

Ignition Determination: Sweep a flame across the cup opening every 2℃ increase in temperature. Record the temperature when a transient blue flame appears and immediately extinguishes.

Test Completion: Clean the equipment and switch off the power supply


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Urinary Catheter Strength Tester
Urinary Catheter Strength Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Urinary Catheter Strength Tester is designed to evaluate the physical strength and mech...
Footwear Comfort Testing Machine for Breathability & Thermal Insulation
Footwear Comfort Testing Machine for Breathability & Thermal Insulation Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Complete Footwear Breathability and Thermal Insulation Test...
Appliance Stability Tester
Appliance Stability Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Appliance Stability Tester is designed to evaluate the mechanical stability and anti-ti...
Vehicle-Level Temperature Humidity Test Chamber Manufacturer
Vehicle-Level Temperature Humidity Test Chamber Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 2423.1 Environmental Testing of Electrical and Electronic Pro...
Perspiration Tester 丨Perspiration Test machine
Perspiration Tester 丨Perspiration Test machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Compliant Standards ISO 105 E01: Textiles - Tests for colour fastness - Part E01: Colour f...
供应产品

Same products

PH-2398  pH/EC/ORP/温度 多参数测试仪
PH-2398 pH/EC/ORP/温度 多参数测试仪 卖方: 科立龙电子股份有限公司 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或...
ORP-2026S  防水型 土壤ORP&温度 二合一测试仪
ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 卖方: 科立龙电子股份有限公司 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
防水型 EC /TDS/温度三合一参数测试仪
防水型 EC /TDS/温度三合一参数测试仪 卖方: 科立龙电子股份有限公司 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ...
EC-98330 电导率营养测试棒
EC-98330 电导率营养测试棒 卖方: 科立龙电子股份有限公司 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0...
PH-808防水笔式土壤PH计
PH-808防水笔式土壤PH计 卖方: 科立龙电子股份有限公司 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保...