Cigarette Draw Resistance Tester
The Cigarette Draw Resistance Tester is designed to measure the airflow resistance encountered by a cigarette during the smoking process. By simulating normal smoking conditions, it provides precise and objective data that supports quality control, product development, and regulatory compliance in the tobacco industry.
Application
(1) Measurement of cigarette draw resistance for quality control during manufacturing.
(2) Evaluation of airflow characteristics for research and development of new tobacco blends, filter designs, and rolling processes.
(3) Random inspections by tobacco regulatory and inspection agencies to ensure products meet relevant standards.
(4) Monitoring and controlling batch-to-batch consistency of draw resistance in production lines.
(5) Verification of filter performance and ventilation design.
(6) Comparison of different cigarette types (e.g., king-size, slim, unfiltered) for sensory quality evaluation.
(7) Assessment of cigarette draw resistance in product optimization and consumer preference studies.
Standards
(1) ISO 6565 – Cigarettes — Determination of draw resistance.
(2) CORESTA Recommended Method No. 6 – International protocol for cigarette draw resistance testing.
(3) GB/T 33029 – China national standard for cigarette draw resistance.
(4) Other applicable national standards depending on the country of manufacture or sale.
Features
(1) Objective Measurement – Provides precise, quantitative evaluation of draw resistance.
(2) Rapid Testing – Average test time of 15 seconds per cigarette.
(3) Automated Operation – Many models offer automatic clamping, testing, and data processing.
(4) Non-Destructive Testing – Test performed on unlit cigarettes without altering their structure.
(5) Real-Time Data Display – Digital output for immediate analysis and quality monitoring.
(6) Versatile Application – Suitable for production, R&D, and regulatory inspections.
Technical Parameters
| Parameter | Specification |
|---|---|
| Measuring Range | 0–10 kPa |
| Resolution | 1 Pa |
| Test Error | <1 % |
| Test Time | ~15 seconds per sample |
| Test Port Inner Diameter | 7.7 mm |
| Test Port Depth | 9 mm |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Output | USB port for computer communication |
| Operating Environment | Room temperature, standard laboratory conditions |
Accessories
(1) Standard cigarette holders/clamps.
(2) Calibration reference devices for pressure and airflow verification.
(3) Software for data logging, analysis, and reporting.
(4) Spare seals and gaskets for test ports.
Test Procedures
(1) Place the unlit cigarette into the clamping device.
(2) Configure the airflow speed according to the selected standard.
(3) Initiate the test; the system measures the pressure difference across the cigarette.
(4) Data processing system calculates the draw resistance value in Pascal (Pa).
(5) Display results on the digital interface or export via USB.
(6) Repeat for multiple samples to ensure batch consistency.
Maintenance Information
(1) Clean test ports and clamps after each use to prevent residue buildup.
(2) Calibrate pressure sensors and airflow system regularly.
(3) Avoid exposure to excessive dust, moisture, or vibration.
(4) Check USB connectivity and software updates periodically.
(5) Inspect mechanical clamps for wear or damage to ensure accurate readings.
在线联系供应商
Other supplier products
| Intramedullary Nails Internal-fixation Pull-out Force Tester | Standard ASTM F543: Standard specification for metallic medical bone screws (dynamic loading protocols). ISO 12172: Implants for surgery—Pa... | |
| Protective Clothing Resistance Tester | Related Standards GB/T 22042 - 2008 Clothing - Anti-static Performance - Test Method for Surface Resistivity GB/T 22043 - 2008 Clothing - Anti-st... | |
| Ink printing proof press meter | How it works: Ink printing proof machine is mainly based on the principle of printing reproduction, through the simulation of the press pressure, ... | |
| Safety shoe impact testing machine | The Safety Shoe Impact Testing Machine is designed to evaluate the impact resistance of protective toecaps in safety footwear by simulating the eff... | |
| Syringe Sealing Positive Pressure Tester | The Syringe Sealing Positive Pressure Tester is a precision instrument designed to evaluate the tight-fitting performance of disposable syringes. I... |
Same products
| Air Permeability Tester STD- F8 | 卖方: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | 卖方: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | 卖方: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | 卖方: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | 卖方: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |