Cigarette Draw Resistance Tester

The Cigarette Draw Resistance Tester is designed to measure the airflow resistance encountered by a cigarette during the smoking process. By simulating normal smoking conditions, it provides precise and objective data that supports quality control, product development, and regulatory compliance in the tobacco industry.

Application

(1) Measurement of cigarette draw resistance for quality control during manufacturing.

(2) Evaluation of airflow characteristics for research and development of new tobacco blends, filter designs, and rolling processes.

(3) Random inspections by tobacco regulatory and inspection agencies to ensure products meet relevant standards.

(4) Monitoring and controlling batch-to-batch consistency of draw resistance in production lines.

(5) Verification of filter performance and ventilation design.

(6) Comparison of different cigarette types (e.g., king-size, slim, unfiltered) for sensory quality evaluation.

(7) Assessment of cigarette draw resistance in product optimization and consumer preference studies.

Standards

(1) ISO 6565 – Cigarettes — Determination of draw resistance.

(2) CORESTA Recommended Method No. 6 – International protocol for cigarette draw resistance testing.

(3) GB/T 33029 – China national standard for cigarette draw resistance.

(4) Other applicable national standards depending on the country of manufacture or sale.

Features

(1) Objective Measurement – Provides precise, quantitative evaluation of draw resistance.

(2) Rapid Testing – Average test time of 15 seconds per cigarette.

(3) Automated Operation – Many models offer automatic clamping, testing, and data processing.

(4) Non-Destructive Testing – Test performed on unlit cigarettes without altering their structure.

(5) Real-Time Data Display – Digital output for immediate analysis and quality monitoring.

(6) Versatile Application – Suitable for production, R&D, and regulatory inspections.

Technical Parameters

ParameterSpecification
Measuring Range 0–10 kPa
Resolution 1 Pa
Test Error <1 %
Test Time ~15 seconds per sample
Test Port Inner Diameter 7.7 mm
Test Port Depth 9 mm
Power Supply AC 100–240 V, 50/60 Hz
Data Output USB port for computer communication
Operating Environment Room temperature, standard laboratory conditions

Accessories

(1) Standard cigarette holders/clamps.

(2) Calibration reference devices for pressure and airflow verification.

(3) Software for data logging, analysis, and reporting.

(4) Spare seals and gaskets for test ports.

Test Procedures

(1) Place the unlit cigarette into the clamping device.

(2) Configure the airflow speed according to the selected standard.

(3) Initiate the test; the system measures the pressure difference across the cigarette.

(4) Data processing system calculates the draw resistance value in Pascal (Pa).

(5) Display results on the digital interface or export via USB.

(6) Repeat for multiple samples to ensure batch consistency.

Maintenance Information

(1) Clean test ports and clamps after each use to prevent residue buildup.

(2) Calibrate pressure sensors and airflow system regularly.

(3) Avoid exposure to excessive dust, moisture, or vibration.

(4) Check USB connectivity and software updates periodically.

(5) Inspect mechanical clamps for wear or damage to ensure accurate readings.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

FPC Flex Durability meter
FPC Flex Durability meter Standard ASTM F392 Product features 1. the stepper motor drive, high-precision positioning, low noise, can be used for a long time 2. program-c...
PV Hail Impact Tester
PV Hail Impact Tester Standard Compliance IEC 61215: Mechanical load testing for terrestrial photovoltaic modules. UL 61730: Safety standards for photovoltaic modules ...
Wet leakage current test system of photovoltaic module
Wet leakage current test system of photovoltaic module The Wet Leakage Current Test System is designed for high-precision evaluation of insulation resistance and leakage current in photovoltaic modules ...
Rubber Resilience Tester
Rubber Resilience Tester Standard Complies withISO 4662:1986(international),JIS K6255(Japan), andGB/T 1681(China) standards for standardized resilience testing of vulcaniz...
Bone Screw Pull-out Tester
Bone Screw Pull-out Tester Standard YY/T 1504. ASTM F543: standard specifies a test method for measuring the axial force required to extract or fail a metallic bone screw f...
All supplier products

Same products

Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 Seller: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...
Surface Performance Tester STD-FB4 - A
Surface Performance Tester STD-FB4 - A Seller: Standard International Group (HK) Limited Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti...
Compression Tester STD - FB3 - A
Compression Tester STD - FB3 - A Seller: Standard International Group (HK) Limited TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar...
Single - Strand Bending Tester STD - FB2 - SH
Single - Strand Bending Tester STD - FB2 - SH Seller: Standard International Group (HK) Limited Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ...
Bending Tester STD- FB2 - S
Bending Tester STD- FB2 - S Seller: Standard International Group (HK) Limited Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig...