Leather edge oil fatigue testing machine

The Leather Edge Oil Fatigue Testing Machine is designed to evaluate the fatigue resistance of edge coatings applied on leather, synthetic leather, or recycled leather. Edge oil, typically composed of polyvinyl chloride, polyurethane, and other resins, is applied to leather edges for protection and aesthetic finishing. This instrument simulates repeated mechanical stress by kneading or rolling the coated leather edges under controlled loads, assessing durability and performance under real-world conditions.

Application

(1) Testing leather edge oil fatigue resistance in footwear manufacturing.

(2) Quality assessment of leather goods such as handbags, belts, and wallets.

(3) Evaluation of synthetic leather and PU-coated fabrics for edge coating durability.

(4) R&D of new edge oil formulations and coating materials.

(5) Inspection of recycled leather products for coating performance.

(6) Testing of colored or pigmented edge coatings to ensure color stability and adhesion.

(7) Industrial quality control for leather processing plants and finishing workshops.

Standards

(1) QB/1333-2018 – Leather edge oil fatigue resistance testing standard.

(2) QB/1618-2018 – Leather products edge coating performance specification.

(3) QB/T 5246-2018 – Testing method for coated leather edge fatigue.

(4) ISO 11640 – Leather — Tests for color fastness (optional for related edge oil evaluation).

(5) ASTM D1790 – Standard test method for flexing resistance of coated leather.

(6) EN ISO 5402 – Leather and coated leather — Determination of surface durability.

Features

(1) Touchscreen controller for easy operation and digital parameter setting.

(2) Adjustable transverse speed and travel for precise simulation of mechanical stress.

(3) Multi-directional sample clamps allowing both longitudinal and lateral movement.

(4) Configurable load-bearing system for testing under various applied weights.

(5) Automated counting system up to eight digits for long-cycle tests.

(6) Compact and robust design suitable for laboratory and production environments.

Parameters

ParameterSpecification
Longitudinal Loading Mode 200g – 5000g superimposed weight
Lateral Travel 0 – 50 mm adjustable
Fixture Height 45 mm
Transverse Speed 0 – 120 ±1 times/min
Controller Touchscreen, speed and cycle count control
Sample Clamps Bidirectional movement (left/right & forward/backward)
Dimensions [Dependent on manufacturer, typical bench-top size]
Power Supply AC220V, 50Hz

Accessories

(1) Sample clips (pair)

(2) Calibration weight set

(3) Power cable

(4) Product qualification certificate

(5) User manual

(6) Delivery and acceptance documentation

Test Procedures

(1) Prepare the leather sample with edge oil applied.

(2) Install the sample in the clamps, ensuring proper alignment.

(3) Set the desired load on the longitudinal loading system.

(4) Adjust transverse speed and travel distance according to the testing plan.

(5) Start the machine and monitor the test cycle.

(6) Record the number of cycles until visible fatigue, cracking, or failure occurs.

(7) Analyze results for edge oil performance and durability.

Maintenance Information

(1) Regularly clean clamps and moving parts to prevent residue buildup.

(2) Lubricate mechanical joints and guide rails periodically.

(3) Verify load calibration and speed accuracy before each test.

(4) Keep the instrument in a dry, temperature-controlled environment.

(5) Inspect touchscreen and electrical components for damage or wear.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Filter Media Test System丨Filter Media System
Filter Media Test System丨Filter Media System Filter Media Test System Gellowen has developed its filter media testing system of G505 for the determination of particle concentration, dust pene...
Building material flame retardancy test furnace,building code compliance equipment
Building material flame retardancy test furnace,building code compliance equipment Technical parameters: Gas used: methane flow rate (35 ± 0.5)L/min, its purity is greater than 95%, air flow rate (17±0.2)L/min Spec...
Model Coin-cell Swelling System
Model Coin-cell Swelling System The Model Coin-Cell Swelling System is designed for in-situ measurement of thickness and volume changes of coin-type lithium-ion cells during charg...
ASTM F963 Nail Bed Flammable Tester
ASTM F963 Nail Bed Flammable Tester G963 Nail Bed Flammable Tester, It is suitable for the burning performance test of cloth toys and filling materials. Perform the flammability of th...
Protective Clothing Liquid Static Pressure Tester
Protective Clothing Liquid Static Pressure Tester Standards GB24540-2009,LFY-252 Instrument use The acid-proof clothing material anti-seepage acid static acid pressure tester is used to measure ...
供应产品

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 卖方: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer 卖方: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester 卖方: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool 卖方: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester 卖方: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...