Micro Rapid Closed Cup Flash Point Tester(Pensky Martens)

Automatic Flash Point Tester designed for accurate and repeatable determination of the flash point of petroleum products using the Pensky-Martens closed cup method, fully compliant with ASTM D93.

The flash point of a material is the lowest temperature at which it emits enough vapor to ignite in air in the presence of an ignition source. It is a critical parameter for determining the flammability and safety classification of fuels, oils, solvents, and other volatile substances.

Applications

Petroleum & Petrochemical Industry – Testing fuels, base oils, lubricants

Paints & Coatings – Verifying solvent flash points

Pharmaceuticals & Chemicals – Assessing flammability characteristics

Transport & Safety Compliance – Ensuring materials meet regulatory flash point requirements

Environmental & Quality Labs – Standardized material classification

Standards

SN/T 3077.1-2012: Chemicals—Determination of flash point—Part 1: Closed-cup equilibrium method

SN/T 3077.2-2012: Chemicals—Determination of flash point—Part 2: Closed-cup rapid equilibrium method

SH/T 0768-2005: Determination of total contaminants in middle distillate fuel oils—High-temperature filtration method

DL/T 1354-2014: Preparation method of working standard oil for analysis of dissolved gas components in transformer oil

ASTM D93: Pensker-Martins closed-cup flash point determination

ASTM D6450: Small closed-cup flash point determination method

ASTM D3828: Small closed-cup device method for determining the flash point of liquids

ASTM D7094: Improved continuous closed-cup flash point determination method

ASTM D7236: Improved Abel closed-cup flash point determination method

ASTM D56: Tiger closed-cup flash point determination method

ISO 2719: Petroleum products—Determination of flash point—Pensker- Martins Closed Cup Method

ISO 13736: Petroleum Products - Determination of Flash Point - Abel Closed Cup Method

ISO 1516: Petroleum Products - Determination of Flash Point - Tiger Closed Cup Method

ISO 1523: Petroleum Products - Determination of Flash Point - Small Closed Cup Method

IP 34: Determination of Flash Point - Abel Closed Cup Tester Method

IP 304: Determination of Flash Point - Small Closed Cup Method

IP 170: Determination of Flash Point - Pensker-Martins Closed Cup Tester Method

DIN EN 22719: Petroleum Products - Determination of Flash Point - Pensker-Martins Closed Cup Method

JIS K2265: Petroleum Products - Determination of Flash Point

NF M 07-019: Petroleum Products - Determination of Flash Point - Pensker-Martins Closed Cup Method

Features

1. It adopts the advanced continuous closed - cup flash - point test method, which is more accurate and efficient.

2. It requires a small sample amount, resulting in low test costs and minimal pollution.

3. With continuous closed - cup operation, there is no open flame, ensuring high safety.

4. It has a built - in refrigeration module, offering a wide flash - point test range and a fast cooling rate.

5. Standard test methods are preset and can be associated with other closed - cup methods.

6. It features fully automated detection and automatically corrects the flash - point based on atmospheric pressure.

7. It displays temperature and pressure curves in real - time, making the test process more intuitive.

8. The test results include a temperature - pressure rise curve, providing more information about flash combustion.

9. Key components are from well - known international brands, ensuring long - term stable operation.

10. It supports user - level management, enabling the management and control of accounts at different levels.

11. The USB interface is plug - and - play. An optional thermal printer is available for convenient data management.

12. It is equipped with a 7 - inch color touch screen that supports Chinese input, making the operation intuitive and simple.

Technical Parameters

Operating Environment

(5~40)℃, <85%RH

Temperature Range

(0~260)℃

Rising Rate

(-30~260)℃ (with low-temperature module)

Temperature Detection Accuracy

(0~420)℃ (with high-temperature module)

Pressure Detection Range

(-30~420)℃ (with low-temperature and high-temperature modules)

Sample Volume

(2.5±0.3)℃/min, (5.5±0.5)℃/min,

Ignition Method

(0.5~12)℃/min Customized

Stirring Speed

±0.1℃

Storage Space

(0~200)kPa

Interface

1mL or 2mL

Power

High-pressure electronic ignition

Power

(50~300)rpm software can be set

Dimensions

5000 test results

Weight

RS232*1. RJ45*1. USB*2

Accessoriess

1. Binsky-Martin Closed Cup Kit (includes a dedicated cup body and sealing cap, suitable for closed cup testing requirements)

2. Micro-sample pipette (matches the instrument's micro-sample volume injection requirements)

3. Spare ignition needle/igniter assembly (a spare part to ensure stable ignition function)

4. Sealing ring for closed cup (a consumable sealing component for closed cup testing)

5. Spare temperature sensor probe (a core spare part for temperature detection)

6. Standard flash point sample for calibration (a known flash point standard oil compatible with ASTM D93, used for instrument calibration)

7. Dedicated cleaning tools (such as brushes and wiping cloths, for cleaning and maintenance of components such as the cup body)

Test Procedures

Procedure A: For fuels and liquids with flash points between 40°C and 360°C

Procedure B: For materials with potential surface films or those prone to forming skin

Procedure C: For biodiesel blends and other specified fuel mixtures


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Micro Rapid Closed Cup Flash Point Tester
Micro Rapid Closed Cup Flash Point Tester Reference Standards: SH/T 0768. SN/T 3077.1. DL/T 1354. ASTM D6450 SN/T 3077.2. ASTM D7094 GB/T 261. GB/T 21615. ASTM D93 GB/T 5208. GB/T 21790. A...
Catheter Flow Meter
Catheter Flow Meter The Catheter Flow Meter is specifically designed for measuring the water flow rate of medical catheters, including non-vascular catheters, intravas...
FPC Flexibility Endurance Tester (for FPC Flex Durability Tester)
FPC Flexibility Endurance Tester (for FPC Flex Durability Tester) Standard ASTM F392 Product features 1. the stepper motor drive, high-precision positioning, low noise, can be used for a long time 2. program-c...
High Velocity Impact Testing Machine
High Velocity Impact Testing Machine Main Purpose To test the impact - resistance performance of glasses, goggles and face shields at a certain speed. Applicable Standards SNELL SA/...
UV Xenon Arc Weather Testing Chamber
UV Xenon Arc Weather Testing Chamber Product introduction This equipment uses xenon arc lamp that can simulate the whole spectrum of sunlight reproduction under different environments...
供应产品

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 卖方: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer 卖方: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester 卖方: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool 卖方: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester 卖方: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...