Photovoltaic Ammonia Test Chamber

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The Photovoltaic Ammonia Test Chamber is a testing device designed to evaluate the corrosion resistance of photovoltaic modules in ammonia environments, ensuring their long-term stable operation in harsh conditions such as industrial or agricultural settings.

Standards

IEC 62716: Photovoltaic (PV) modules—Ammonia corrosion testing (The core standard for this equipment).

IEC 61701: Salt mist corrosion testing of photovoltaic (PV) modules.

IEC 60068-2-52: Environmental testing—Part 2-52: Tests—Test Kb: Salt mist, cyclic (sodium chloride solution).

GB/T 2423.17 / GB/T 2423.18: Environmental testing for electric and electronic products—Salt mist testing methods.

IEC Draft 82/722/CDV: Specific requirements for integrated salt mist and ammonia gas exposure sequences.

Features

This equipment can independently perform all test procedures required by IEC 61701 and IEC Draft Standard 82/722/CDV. Specifically, spray testing at severity levels 1-6. damp heat storage, standard atmospheric environment testing, and sample cleaning phases are all completed within the NaCl corrosion chamber. Ammonia spray testing, damp heat storage, spray washing, and drying can all be performed within the NH3 corrosion chamber.

Parameters

ItemSpecifications
NH₃ Concentration 0–10000 ppm (adjustable)
Ammonia Concentration Resolution ±1 ppm
Temperature Control Range 15°C ~ 70°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Deviation ≤ ±1.0°C
Temperature Uniformity ≤ ±2°C
Humidity Control Range 40% ~ 100% RH (adjustable)
Humidity Deviation ≤ ±2% RH
Humidity Uniformity ≤ ±3% RH
Test Accuracy ±2%

Accessories

1.Ammonia Gas Dosing System: Precision mass flow controllers for accurate gas injection.

2.Ammonia Concentration Sensor: High-precision electrochemical or laser-based gas detectors.

3.Specimen Racks: Non-reactive, adjustable holders designed to support full-sized PV modules at standard angles.

4.Exhaust Scrubber Unit: A chemical neutralization system to safely treat ammonia-laden air.

5.NaCl Spray Module: Integrated nozzles and reservoir for salt mist phases (Standard Severity 1-6).

6.Deionized Water Rinse: Internal spray bars for automated sample cleaning between test stages.

Test Procedures

1.‌Preparation‌

‌Sample Preparation‌: Clean samples and secure them on the sample rack, ensuring they do not touch each other.

‌Solution Preparation‌: Prepare a 5% NaCl solution (pH 6.5-7.2) according to the standard.

2.‌Power-On Test

‌Power Connection‌: Connect the power supply and turn on the main switch.

3. Test Operation

Start Test: After confirming parameters are correct, press the “Start” button.

Spray Inspection: Once temperature is reached, the spray system will automatically activate. Observe spray uniformity.

4. Test Completion

Shutdown Procedure: Turn off the spray switch. Allow cooling to below 40°C before disconnecting power.

Sample Removal: Remove specimens for corrosion assessment.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

MST Medical Compression Stocking Tester Manufacturer | ISO 13994 Compression Hosiery Testing Equipment
MST Medical Compression Stocking Tester Manufacturer | ISO 13994 Compression Hosiery Testing Equipment Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ISO 13994 – Medical Compression Garments Standard (2) A...
Air Intake Filter Performance Test System
Air Intake Filter Performance Test System Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This system is used for: Engine Air Intake Filters: Testing filtration perfor...
Industrial oil separator test system factory direct
Industrial oil separator test system factory direct Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Oil Separator Test Rigis designed for automated testing procedures in ord...
Battery Membrane Breathability Test Machine JIS Standard
Battery Membrane Breathability Test Machine JIS Standard Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 458 – Battery diaphragm gas permeability test metho...
ISO Battery Abuse Testing machine
ISO Battery Abuse Testing machine Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Battery Cell Test Pressure Vessel is designed for thermal runaway testing...
供应产品

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFull-Body Garment Stress Testeris a pr...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com TheIndustrial Dry Cleaning and Energy-Sav...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The MST Medical Compression Stocking Test...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Textile Manufacturing:Testi...
Dental material color stability tester
Dental material color stability tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The applications of color st...