High Pressure PTA Balloon Catheter
OVERVIEW
High Pressure PTA Balloon Catheter
Deliver great outcomes for both AV and vascular access patency
The Percutaneous Transluminal Angioplasty HP PTA Balloon Catheter are non-reusable semi-compliant coaxial design catheters consisting of an over-the-wire (OTW) catheter with a balloon mounted on its distal tip.
PRODUCT FEATURES
High Pressure Balloon Catheters
ZENFLOW-35
Balloon Materials (Nylon+Pebax)
Permit thinner wall thickness with higher RBP and lower compliance
Advanced balloon folding technology
Provides consistent low profiles and excellent re-wrap
SOFT AND LOW ENTRY PROFILE TIP
High radial strength and good fracture resistance
To maximize vessel patency by decreasing tissue prolapse
GOLD/TANTALUM MARKER
Creates easy access to the most complex anatomy
DUAL LUMEN SHAFT DESIGN
Provides short deflation time and good push-ability
One-handed stent deployment
THE BROADEST WORKING RANGE
Balloon Diameter: 3-10mm
Balloon Length: 20-200mm
Shafts: 40, 75, 135cm
TECHNOLOGY DATA
Catheter Type: Over-The-Wire(OTW)
Guidewire: 0.025"
Balloon folding: 3-fold[∅3mm]/6-fold[∅4-10mm]
Coating: Hydrophilic coating
Balloon Markers: 2
ORDERING INFORMATION
Catheter Length |
Balloon Diameter |
Balloon Length |
Sheath |
NP |
RBP |
||||
40cm |
75cm |
135cm |
(mm) |
(mm) |
(F) |
ATM |
kPa |
ATM |
kPa |
ZWHB |
ZWHB |
ZWHB |
3 |
20 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
3 |
30 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
3 |
40 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
3 |
60 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
3 |
80 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
3 |
100 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
3 |
120 |
5 |
10 |
1013 |
24 |
2432 |
一 |
ZWHB |
ZWHB |
3 |
150 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
3 |
180 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
3 |
200 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
4 |
20 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
4 |
30 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
4 |
40 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
4 |
60 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
4 |
80 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
4 |
100 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
4 |
120 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
4 |
150 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
4 |
180 |
5 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
4 |
200 |
5 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
20 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
30 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
40 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
60 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
80 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
100 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
5 |
120 |
6 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
5 |
150 |
6 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
5 |
180 |
6 |
10 |
1013 |
24 |
2432 |
— |
ZWHB |
ZWHB |
5 |
200 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
20 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
30 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
40 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
60 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
80 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
100 |
6 |
10 |
1013 |
24 |
2432 |
ZWHB |
ZWHB |
ZWHB |
6 |
120 |
6 |
10 |
1013 |
22 |
2229 |
— |
ZWHB |
ZWHB |
6 |
150 |
6 |
10 |
1013 |
22 |
2229 |
— |
ZWHB |
ZWHB |
6 |
180 |
6 |
10 |
1013 |
22 |
2229 |
— |
ZWHB |
ZWHB |
6 |
200 |
6 |
10 |
1013 |
22 |
2229 |
ZWHB |
ZWHB |
ZWHB |
7 |
20 |
6 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
7 |
30 |
6 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
7 |
40 |
6 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
7 |
60 |
6 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
7 |
80 |
6 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
7 |
100 |
6 |
10 |
1013 |
20 |
2027 |
— |
ZWHB |
ZWHB |
7 |
120 |
6 |
10 |
1013 |
18 |
1824 |
— |
ZWHB |
ZWHB |
7 |
150 |
6 |
10 |
1013 |
18 |
1824 |
— |
ZWHB |
ZWHB |
7 |
180 |
6 |
10 |
1013 |
18 |
1824 |
— |
ZWHB |
ZWHB |
7 |
200 |
6 |
10 |
1013 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
8 |
20 |
7 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
8 |
30 |
7 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
8 |
40 |
7 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
8 |
60 |
7 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
8 |
80 |
7 |
10 |
1013 |
20 |
2027 |
ZWHB |
ZWHB |
ZWHB |
8 |
100 |
7 |
10 |
1013 |
20 |
2027 |
— |
ZWHB |
ZWHB |
8 |
120 |
7 |
10 |
1013 |
18 |
1824 |
一 |
ZWHB |
ZWHB |
8 |
150 |
7 |
10 |
1013 |
18 |
1824 |
— |
ZWHB |
ZWHB |
8 |
180 |
7 |
10 |
1013 |
18 |
1824 |
— |
ZWHB |
ZWHB |
8 |
200 |
7 |
10 |
1013 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
9 |
20 |
7 |
8 |
811 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
9 |
30 |
7 |
8 |
811 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
9 |
40 |
7 |
8 |
811 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
9 |
60 |
7 |
8 |
811 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
9 |
80 |
7 |
8 |
811 |
18 |
1824 |
ZWHB |
ZWHB |
ZWHB |
10 |
20 |
7 |
8 |
811 |
14 |
1419 |
ZWHB |
ZWHB |
ZWHB |
10 |
30 |
7 |
8 |
811 |
14 |
1419 |
ZWHB |
ZWHB |
ZWHB |
10 |
40 |
7 |
8 |
811 |
18 |
1419 |
ZWHB |
ZWHB |
ZWHB |
10 |
60 |
7 |
8 |
811 |
18 |
1419 |
ZWHB |
ZWHB |
ZWHB |
10 |
80 |
7 |
8 |
811 |
18 |
1419 |
INDICATIONS
High Pressure BalloonCatheter
The HP PTA Balloon Catheter is indicated for percutaneous transluminal angioplasty (PTA) in the peripheral vasculature, including iliac, femoral, popliteal, tibial, peroneal, subclavian and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae.
Zylox Medicalisa leading player in the peripheral and neurovascular interventional medical device market in China. As a fully integrated medical device company, we have strong R&D and manufacturing capabilities, multiple specialized technology platforms, and proven commercialization capabilities. Led by our talented management team, we strive to provide best medical services and cutting-edge technical solutions to physicians and patients in China and around the world.
在线联系供应商
Other supplier products
Thrombite Clot Retriever Device | What Is a Stent Retriever? Thrombite™ Clot Retrieval Devices HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite&t... | |
Peripheral Stent System | OVERVIEW Peripheral Stent System The ZENFLEX® Peripheral Stent System is designed to deliver a self-expanding stent to the iliac artery, supe... | |
Thrombite™ Clot Retriever Device | OVERVIEW Thrombite™ Clot Removal Device HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite™ Mechanical Clot... | |
Vascular Snare | Vascular Snare In January 2020, ThromBite™ Clot Retriever Device, independently developed by Zhuhai TonBridge MedicalTech. Co., Ltd, gaine... | |
NEURO INTERVENTIONS | NEURO INTERVENTIONS One of the top neurovascular device companiesin China The pursuit of excellence is the best expression of care for life and o... |
Same products
Sphincterotome - RX series | 卖方: Leo Medical Co.,Ltd. | Used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP op... | |
Single-use Stone Retrieval Basket- RX series | 卖方: Leo Medical Co.,Ltd. | This ERCP basket stone retrieval is used for endoscopic removal of biliary stones and foreign bo... | |
Single-use Stone Retrieval Basket | 卖方: Leo Medical Co.,Ltd. | Used for endoscopic removal of biliary stones and foreign bodies. Features of Single-use Stone R... | |
Single-use Stone Extraction Catheter | 卖方: Leo Medical Co.,Ltd. | Biliary stone extraction balloon catheter is used for endoscopic removal of biliary stones. LeoM... | |
Single-Use Pulmonary Balloon Dilatation Catheter | 卖方: Leo Medical Co.,Ltd. | Used for endoscopic dilate strictures of the airway tree. Features of Single-Use Pulmonary Airwa... |