Brushless Small Electric instant water heater pump
TL-C01-A
- Max Flow Rate: 20L/MIN 24L/MIN
- Max Static Lift: 8M,11M
- Rated Voltage: 12V / 24V
- Impeller Type: Closed impeller
- Motor Type: Three-phase brushless DC motor
- Food Grade(Y/N): Y
■ Overview Our TL-C series design features micro centrifugal pumps powered by brushless DC motors. They are designed to be cool, quiet, compact and lightweight. A variety of features, including a seal-less design to prevent leakage, wide range of working voltage, stable performance, long life time, enable the pumps to meet a full spectrum of user needs, with emphasis on ease of installation, operation and maintenance.Features:●The micro centrifugal pumps have the three-phase ECM brushless DC motor, high efficiency, low consumption, long life time, multifunctional control, start small power.●Taken the advanced magnetic drive technology, the rotor-impeller and the shaft are sealed together independentlyfrom other parts, without any leak for ever.●The reliability is because of pump only contains one moving part: the magnetically driven rotor-impeller spins on a single ceramic bearing, high precision, well wear resistance, thus extending the life of this pump beyond existing standards.●TOPSFLO Unique Closed Impeller -- dynamically balanced, higher efficiency, stronger pressure performance, steady flow, smooths ultra quiet operation.●Three-phase brushless DC pump can achieve PWM speed control, analog signal (0~5 V) or manual potentiometer speed control, can be achieved on the head and flow regulation.●Three-phase brushless DC pump have the advantage of various protection functions such as: impeller stuck protection, over-voltage protection, overload protection, over-current protection, reverse polarity protection (optional), dry-running protection (optional).Definitions:Dry-running protection (customized functions)Drive circuitry can detect no or little liquid in pump chamber and will stop the pump to prevent damage, pump is then restarted manually by disconnecting and reconnecting it to the power supply.Over voltage protectionWhen the voltage over 28V, the pump will auto-protect and shut off own power supply, when the voltage falls below 28V, the pump will restart automatically.Over load protection functionThis means that when the current is over the rated current, such as can arise if the impeller is stuck due to debris. The pump will automatically stop to prevent damage, and will restart when the current falls again.Application: The centrifugal brushless pumps are designed for general, commercial and industrial applications. Ideal for circulation pump applications. They will pump fresh water, seawater, and other liquids that are compatible with the pumps materials and that are of similar viscosity to water. 1. Liquid transfer general purpose pumping2. Hot water circulating system3. Electronics Cooling Water Circulation Chiller Systems4. Liquid filling and transfer in food, beverage processing, vending machines5. Instant electric water heater, electric shower.6. Circulating systems for homes, RV's and boats7. Cleaning equipment, purification and water treatment.8. Irrigation solar pump, swimming pool circulation9. Electric cars: radiators, heaters10. Automotive air conditioning 11. Computer CPU cooling circulation12. Water heating mattressUsage Note:1.Dry-running is prohibited.2.Reverse polarity is not allowed (except customized).3.The pump if dropped or with heavy vibration do not use.4.Liquid contain impurities or magnetic particles are not allowed.5.Liquid temperature over 90°C is not allowed (except high temperature models).■ Specifications
1 |
Max Flow Rate |
20L/MIN 24L/MIN |
2 |
Max Static Lift |
8M ,11M |
3 |
Rated Voltage |
12V / 24V |
4 |
Impeller Type |
Closed impeller |
5 |
Motor Type |
Three-phase brushless DC motor |
6 |
Food Grade(Y/N) |
Y |
7 |
Liquid Temperature |
0-100°C |
8 |
Pump Theory |
Centrifugal pump |
9 |
Ambient Temperature |
-10-50°C |
10 |
Media |
Pure Water |
11 |
Waterproof Class |
IP42 |
12 |
Use Place |
Indoor or Outdoor |
13 |
Working Voltage Range |
6~16V or 12~28V |
14 |
Power Consumption |
25W,53W |
15 |
Noise Class form 1M |
48dB /Max |
16 |
Ideal Life Time |
20000 Hours |
17 |
Working Mode |
Continuous |
18 |
OD of Inlet |
18 mm |
19 |
OD of Outlet |
18 mm |
20 |
Dimension |
89.3x60.34x88.29 mm |
21 |
Power Supply |
DC power supply, battery, solar powered |
22 |
Protection Functions |
automatic blocked protection,, overvoltage protection, overcurrent protection, overload protection |
23 |
Flow Rate Regulation |
(customized functions) PWM, 0~5V speed control |
24 |
Remarks |
Can’t dry-running, not Self-priming |
■ Parameter
Model |
Product Code |
Max Water Flow (L/Min) |
Rated Voltage(DC) |
Rated Current (A) |
Max Water Head(M) |
Rated Power(W) |
|
TL-C01-A12-1706 |
17±15% |
12VDC |
2.2±15% |
6±1 |
26.4 |
|
TL-C01-B12-1606 |
16±15% |
12VDC |
2.2±15% |
6±1 |
26.4 |
TL-C01-A |
TL-C01-C12-1706 |
17±15% |
12VDC |
2.2±15% |
6±1 |
26.4 |
circle nozzles |
TL-C01-A24-1908 |
19±15% |
24VDC |
1.5±15% |
8±1 |
36 |
φ18mm/φ18mm |
TL-C01-B24-1808 |
18±15% |
24VDC |
1.5±15% |
8±1 |
36 |
|
TL-C01-C24-1908 |
19±15% |
24VDC |
1.5±15% |
8±1 |
36 |
|
/H(70℃<liquid≤100℃) |
|
|
|
|
|
|
|
|
TL-C01-A12-2008 |
20±15% |
12VDC |
2.8±15% |
8±1 |
34 |
|
TL-C01-B12-1908 |
19±15% |
12VDC |
2.8±15% |
8±1 |
34 |
|
TL-C01-C12-2008 |
20±15% |
12VDC |
2.8±15% |
8±1 |
34 |
TL-C01-B |
TL-C01-A24-2411 |
24±15% |
24VDC |
2±15% |
11±1 |
48 |
barb nozzles |
TL-C01-B24-2211 |
22±15% |
24VDC |
2±15% |
11±1 |
48 |
φ19.5mm/φ10mm |
TL-C01-C24-2411 |
24±15% |
24VDC |
2±15% |
11±1 |
48 |
|
|
|
|
|
|
|
|
TL-C01/5V-A24-2411 |
24±15% |
24VDC |
2±15% |
11±1 |
48 |
|
TL-C01/5V-B24-2211 |
22±15% |
24VDC |
2±15% |
11±1 |
48 |
|
TL-C01/5V-B24-2411 |
24±15% |
24VDC |
2±15% |
11±1 |
48 |
|
special Instant Water Heater pump with additional 0~5V wire for PWM speed adjustment function ( at 0V not working, at 5V run on full speed ) |
|
|
|
|
|
|
|
|
TL-C01/S/PV-A12-2008-W |
20±15% |
12V (7V~24V) |
2.8±15% |
8±1 |
34 |
TL-C01-C |
TL-C01/S/PV-B12-1908-W |
19±15% |
12V (7V~24V) |
2.8±15% |
8±1 |
34 |
thread nozzles |
TL-C01/S/PV-C12-2008-W |
20±15% |
12VDC |
2.8±15% |
8±1 |
34 |
G1/2 |
TL-C01/S/PV-A24-2411-W |
24±15% |
24V (14V~32V) |
2±15% |
11±1 |
55 |
|
TL-C01/S/PV-B24-2211-W |
22±15% |
24V (14V~32V) |
2±15% |
11±1 |
55 |
|
TL-C01/S/PV-C24-2411-W |
24±15% |
24VDC |
2±15% |
11±1 |
55 |
|
special submersible pump with 1.5M cable wire, can be powered by solar panel directly,rated 12/24V, used as submersible liquid should be ≤50℃. |
Note: 1.pump itself meet: /F,food grade 2. /H type 70℃<liquid≤100℃, not H normal type liquid≤70℃ 3. /S type can be customized, if submersible liquid should be ≤50℃ |
■ Curve & Dimension
Dimension:
Other supplier products
供应产品
Same products