Power Quality Analyzer SA2100
SA2100
SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system.
Brief Introduction
SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system. The PC software can simply upload the data to PC for full analysis.
Main Features
Waveform real-time display(4 voltages/4 currents)
Half-period RMS measurement (voltage and current)
Measurement of TRMS currents up to 5000A (sensor dependent)
Measurement, calculation and display of harmonics and interharmonics can be up to 50 times.
Transient capture
Active power, reactive power, apparent power and energy, shift power factor and true power factor
Three-phase unbalance (voltage and current)
Flicker
Inrush current
Detection and record of Dips& Swells, Voltage Rapid Change, Interruption.
Detect according to EN50160 or grid with user-defined limit
Data storage and screenshots (can be replayed or output to a PC)
Through the LAN interface PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data
Built-in 8G memory card
General Characteristics
|
Display |
|
|
Screen |
Color TFT LCD |
|
Size |
|
|
Resolution |
320×240 |
|
Brightness |
Adjustable |
|
Housing |
|
|
Protection |
Protection shield, strong |
|
IP |
IP51, accords IEC60529 |
|
Interface |
|
|
USB Host |
Download file to PC by U disk for analyze with PC software |
|
LAN |
For remote control of the Analyzer and measurement data transmission. |
|
Memory |
|
|
Flash Memory |
128MB |
|
TF Card |
Standard 8G |
|
Mechanical |
|
|
Dimension |
262× 173 × 66mm |
|
Weight |
|
|
Enviroment |
|
|
Working temperature |
0°C~ 40°C |
|
Storage temperature |
-20°C~ 60°C |
|
Humidity |
90% relative humidity |
|
Power |
|
|
Adapter input |
90~264V |
|
Adapter output |
12V 2A |
|
Battery |
Rechargeable NI-MH ion 7.2V 3.8Ah |
|
Battery Working Time |
undefined 7 hours |
|
Battery Charge Time |
4 hours |
|
Standard |
|
|
Measurement Method |
IEC61000-4-30 Class-S |
|
Measurement Performance |
IEC61000-4-30 Class-S |
|
Power Quality Monitoring |
EN50160 |
|
Flicker |
IEC61000-4-15 |
|
Harmonic |
IEC61000-4-7 |
|
Electrical Safety |
|
|
Comply with |
IEC61010-1 ,Safety Degree: 600V CAT IV 1000V CAT III |
|
600V CAT IV 1000V CAT III |
|
|
42Vpk |
|
Wire Combinations
|
1Ø+NEUTRAL |
Single phase with neutral |
|
1Ø SPLIT PHASE |
Split phase |
|
1Ø IT NO NEUTRAL |
Single phase system with two phase voltages without neutral |
|
3Ø WYE |
3-phase 4-wire system, Y type |
|
3Ø DELTA |
3-phase 3-wire system delta (Delta) |
|
3Ø IT |
3-phase Y type without neutral |
|
3Ø HIGH LEG |
4-wire 3-phase delta system (Delta) with center tapped high leg |
|
3Ø OPEN LEG |
Open-delta (Delta) 3-wire system with two transformer windings |
|
2-ELEMENT |
3-phase 3-wire system without current sensor on phase L2/B (2 Watt meter method) |
|
2 1/2-ELEMENT |
3-phase 4-wire system without voltage sensor on phase L2/B |
Input
|
Voltage Input |
|
|
Input Channels |
4 (3 phase + neutral) DC coupling |
|
1000Vrms |
|
|
Range of nominal voltage |
50 to 500V |
|
Max pulse peak voltage |
6kV |
|
Bandwidth |
undefined3kHz |
|
Input Impedance |
4MΩ/5pF |
|
Current Input |
|
|
Numbers of Input |
4 (3 phase + neutral) DC coupling |
|
Type |
Clamp Current Sensor with mV output |
|
Input Range |
1 to 3000Arms with supplied current clamp |
|
Input Impedance |
50kΩ |
|
Bandwidth |
undefined3kHz |
|
Sampling System |
|
|
Resolution |
8 channels 16 bits AD |
|
Sampling Rate |
20kS/s for each channel, 8 channels sample synchronously |
|
RMS Sampling |
5000 points for 10/12 cycles (according to IEC |
|
PLL Sync |
4096 points for 10/12 cycles (according to IEC61000-4-7) |
Measurement
|
Measurement Range |
Resolution |
Accuracy |
|
|
Voltage/Current/Frequency |
|||
|
Vrms(AC+DC) |
1 ~ 1000Vrms |
±0.5% of nominal voltage |
|
|
Vpk |
1 ~ 1400Vpk |
±0.5% of nominal voltage |
|
|
V(Crest Factor) |
±5% |
||
|
Arms (AC) |
1~ 1000A/3000A/5000A |
1A |
±1% ± 2A |
|
1~ 100A |
±1% ± 0.2A |
||
|
Apk |
1 ~ 4000Apk |
1A |
±1% ± 2A |
|
A(Crest Factor) |
1 ~ 10 |
±5% |
|
|
Frequency |
±0.01Hz |
||
|
51 ~ 69Hz (60Hz nominal) |
±0.01Hz |
||
|
Dips & Swells |
|||
|
Vrms1/2 |
0 ~ 200% of nominal voltage |
±1% |
|
|
Arms1/2 |
1 ~ 3000A |
1A |
±1% ±2A |
|
Threshold levels |
Threshold is settable according to nominal voltage percentage Detectable events type: Dips, Swells, Interruption, Voltage Rapid Change |
||
|
Duration |
hour-minute-second-microsecond |
1 period |
|
|
Harmonic |
|||
|
Harmonic Number |
1 ~ 50 |
||
|
Inter-Harmonic (SA2100) |
1 ~ 49 |
||
|
Harmonic Voltage |
±0.1% ± nx0.1% |
||
|
Harmonic Current |
±0.1% ± nx0.1% |
||
|
THD |
±2.5% |
||
|
DC Relative |
±0.2% |
||
|
Frequency |
0 ~ 3500Hz |
1Hz |
1Hz |
|
Phase |
-360° ~ 0° |
1° |
± nx1.5° |
|
Power and Energy |
|||
|
Active Power/Apparent Power/Reactive Power |
±1.5±10 digits |
||
|
Energe |
10Wh |
±1.5±10 digits |
|
|
Power Factor |
0 ~ 1 |
±0.03 |
|
|
Flicker (only for SA2100) |
|||
|
Pst(1min),Pst,Plt,PF5 |
±5% |
||
|
Unbalance |
|||
|
Voltage |
±0.5% |
||
|
Current |
±1% |
||
|
Voltage Phase |
-360° ~ 0° |
1° |
±2digits |
|
Current Phase |
-360° ~ 0° |
1° |
±5digits |
|
Voltage Transient (only for SA2100) |
|||
|
Vpk |
±6000Vpk |
1V |
±15% |
|
Vrms |
10 ~ 1000Vrms |
1V |
±2.5% |
|
50us |
|||
|
Sampling Rate |
20kS/s |
||
|
Inrush Current (only for SA2100) |
|||
|
Arms(AC+DC) |
0~3000Arms |
±1% ± 5digits |
|
|
Inrush Duration |
6s ~ 32min selectable |
10ms |
±20ms |
|
Logger |
|||
|
Recording |
user-defined parameters for 4 phases at the same time |
||
|
Memory |
Data stored in TF card, 8GB |
||
|
Duration Time |
2 hrs to 1 year |
||
|
Interval |
1s to 1 hrs |
||
在线联系供应商
Other supplier products
| Spectrum Analyzer SA9200 Series | The new high-performance Spectrum Analyzer SA9200 Serieswere developed with all-digital IF technology to meet demanding customer requirements, its ... | |
| Digital Multimeter | SA5041 Digital Bench-Type Multimeter Model SA5041 is the maximum reading 22000 and 4 1/2 digits and could do accurate automatic true RMS measureme... | |
| Programmable DC Power Supplies | SK10000 SK13530 programmable power supply is a new generation of programmable DC power supplies. It protects itself by warning and cutting off out... | |
| Spectrum Analyzer SA9275 Series | Buy low cost spectrum analyzer, Digital Spectrum Analyzerin China, come to suin. We can provide various Spectrum Analyzer with different frequency ... | |
| SU4300 Series Noise Source | Synthesized Signal Generator TFG3630 Series Signal Generators TFG3630 synthesized signal generatorswith PLL technique and use the FPGA to control... |
Same products
| JWL-V6 Portable Physicochemical Meter | 卖方: Shenzhen Joinwe Smart Co.,Ltd | JWL-V6Portable PhysicochemicalMetercan detect the physical and chemical indicators of oil product... | |
| SA-917 折叠盐度计 | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | 范围 0~100.0ppt 准确性 ±2℅F·S 分辨率 0.1幻灯片 ... | |
| SA-3287 防水盐度计 | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | 范围 0~100.0‰ 准确性 ±2℅F·S 分辨率 0.1&perm... | |
| SA-1397 防水盐度和温度计 | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | 自动温度补偿(带温度显示。)*IP55防水等级。 | |
| SA-367 防水迷你盐度计 | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | 范围 0~100.0‰ 准确性 ±2℅F·S 分辨率 0.1&perm... |
















