Plastic Smoke Density Tester ISO 5659

Standards:

GB/T8323.2-2008: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test ISO 5659-1: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test ISO 5659-2: Plastics-Smoke generation-Part2: Determination of optical density by a single-chamber test

Applications:

The main principle of smoke density measurement is that in a particular space, the cable or material produces smoke under specific combustion or radiation conditions, and the light beam penetrating through the smoke will produce attenuation. Measuring the light transmittance and calculation will get the optical density and smoke density.

Product Information:

The main principle of smoke density measurement is that in a particular space, the cable or material produces smoke under specific combustion or radiation conditions, and the light beam penetrating through the smoke will produce attenuation. Measuring the light transmittance and calculation will get the optical density and smoke density.

The instrument is designed and developed according to ISO5659 related standards. With the use of Conical radiation furnace, the heat flux in the chamber can be as high as 50 kW/ m2. and the sample can be positioned horizontally to test the mass loss rate of the sample. This also complies with the latest IMO test terms. Measure the amount of smoke generated when the sample is vertically exposed to a radioactive heat source at 25 kW / m2 when there is or there is no forward flame in confined space.

Using the standard ISO 5659 conical radiant heating furnace, the user can adjust the heating conditions from 10 kW㎡ into 50 kW/㎡ or 70kW/㎡.

Features:

·The tester consists of a chamber, a sample box, a radiant cone, an igniter, a light transmission and measuring device and other related control devices.

·Ergonomic design and control design; chamber with a fully open door ; door lock designed to facilitate one-time closure of the door; optimize the operation process.

·The test chamber door can be fully opened to facilitate loading and unloading samples and cleaning the box;

·Front door, hinge mounted, with window and non-transparent light shading board which can block the window, to prevent light from entering the sealed chamber.

·The controller is located on the side of the chamber for easy operation. When the door is closed, it does not affect the controller to be viewed.

·Safe flameout board, easy to replace, more secure operation.

·A gas measuring port is available for testing gas toxicity.

·The coating of the test chamber is easy to clean and resistant to chemical corrosion.

Combustion Apparatus:

·Heating cone: power 2600W, input temperature range of 0 ~ 1000℃, stable within ± 2℃ within 50 mins, can provide 10KW / m²-50KW / m² of radiation exposure.

·The use of mass flow controllers and differential pressure sensors enhances the accuracy of the manometer and enables automatic leak testing.

·The ignitor is equipped with automatic ignition device; flame length 30mm ± 5mm; in accordance with the standard provisions of blue flame with yellow on the top.


在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Vacuum leak tester / Vacuum leak instrument
Vacuum leak tester / Vacuum leak instrument Vacuum Decay Leak Tester specializes in the detection of leaks in ampoules, vials, injection bottles, freeze-dried powder injection bottles, and pr...
Filter Membrane Pore Analysis Tester
Filter Membrane Pore Analysis Tester Product Introduction: The pore size and distribution within a filter membrane dictate its filtration efficiency, flow rate, and retention capabili...
Shoe bending Angle tester | Sole Bending Tester
Shoe bending Angle tester | Sole Bending Tester Product Introduction: Shoe bending Angle testing machine is mainly used for outsole rigidity test, with a solid block the front of the shoe clampe...
Catheter Flexibility Tester
Catheter Flexibility Tester Compliance Standards YY/T 1554 - 2017. etc. ISO 10555 -Intravascular catheters- Sterile and single-use catheters ISO 11o70- Catheter introducers...
Shoelace Abrasion Tester SATRA TM154
Shoelace Abrasion Tester SATRA TM154 Standards SATRA TM93、DIN-4843、QB/T2226、SATRA TM154 Principle Let shoelace cross the eyelet clamped on the fiber board, make the shoelace and eye...
供应产品

Same products

Bottle Wall and Bottom Thickness Tester
Bottle Wall and Bottom Thickness Tester 卖方: Standard Group (Hong Kong) Limited The wall and bottom thickness tester for bottles is a measuring instrument widely used in the pha...
Pinhole Tester / Pinhole Testing Equipment
Pinhole Tester / Pinhole Testing Equipment 卖方: Standard Group (Hong Kong) Limited The pinhole tester for aluminum foil is a device specifically used to detect micro - pinholes in ...
Cork Puncture and Chip Detection Instrument
Cork Puncture and Chip Detection Instrument 卖方: Standard Group (Hong Kong) Limited The rubber stopper puncture debris detector is a device specifically used to detect the number of...
Aluminum Ointment Tube Toughness Tester
Aluminum Ointment Tube Toughness Tester 卖方: Standard Group (Hong Kong) Limited The ductility tester for aluminum tubes is a device specifically used to detect the ductility ind...
Vacuum leak tester / Vacuum leak instrument
Vacuum leak tester / Vacuum leak instrument 卖方: Standard Group (Hong Kong) Limited Vacuum Decay Leak Tester specializes in the detection of leaks in ampoules, vials, injection bott...