.

Adhesion Tester | Precision Adhesion Tester

The adhesion tester is a device specifically used to detect the strength of the adhesion of materials. The following is a detailed description of its main uses, compliance standards, and technical parameters:

Compliance Standards

- Specific standards for different test objects, such as the adhesion test standards for medical gels, cosmetics and skin

- care products, food packaging materials, etc.

- General standards in the adhesive industry, such as GB/T 2792 Test Method for 180°Peeling Strength of Pressure

- Sensitive Adhesive Tapes, ASTM D3330 Standard Test Method for Peel Adhesion of Pressure - Sensitive Tape, etc. These standards specify in detail the test methods for the adhesion tester, specimen preparation, test conditions, etc., providing a unified standard for the use of the tester.

Main Uses

The adhesion tester has extensive application value in multiple fields, including but not limited to: - Medical Field: It is used to evaluate the adhesion performance of medical products such as medical gels, dressings, and patches, ensuring that they can stably adhere to the skin in practical applications and exert therapeutic effects. - Cosmetics and Skin - care Industry: It tests the adhesion of cosmetic gel products, facial masks, eye creams, etc., to ensure that they can closely fit the skin during use and enhance the product's effectiveness. - Food Manufacturing Industry: It is used to detect the adhesion performance of food - grade gels, packaging materials, etc., ensuring their stability during food processing, packaging, and transportation. - Adhesive Industry: It tests the adhesion of various adhesives, adhesive tapes, labels, etc., to evaluate their quality and performance. - Materials Science Field: It studies the adhesion performance of materials, providing basic data support for material development and application.

Technical Parameters

- Measurement Range: Usually covering 0 - 30000mN or wider to adapt to the testing needs of different materials. Some devices may have a smaller measurement range, such as 0.01N - 100N, which is suitable for measuring materials with relatively low adhesion.

- Measurement Accuracy: Generally grade 0.5 or higher to ensure the accuracy of test results.

- Stroke: Usually 650mm or longer to meet the requirements of different specimen sizes and test methods.

- Pressing Roller Mass: Usually 2000g±50g, used to apply a certain pressure to the specimen to ensure a tight adhesion between the specimen and the test plate.

- Test Speed: The adjustable range is generally 1 - 500mm/min (stepless speed regulation) to simulate different peeling speeds. Some devices may have a wider speed - adjustment range.

- External Dimensions: Usually about 880mm (length) × 320mm (width) × 400mm (height), facilitating placement and movement. The dimensions of devices from different brands and models may vary.

- Power Supply: Usually AC 220V 50Hz to ensure the normal operation of the tester. Some devices may support other voltages and frequencies.


在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Shoelace anti-siphon tester / Shoelace anti-siphon test mechine
Shoelace anti-siphon tester / Shoelace anti-siphon test mechine Product Introduction Shoelace anti-siphon tester is suitable for all kinds of waterproof leather, leather, mesh, waterproof shoelace, ribbon water...
Leather softness tester |  Textile Testing Products
Leather softness tester | Textile Testing Products Product Introduction: Measure the softness of leather and hide to know whether the softness of the same batch of leather is uniform, or the softne...
Catheter Flexibility Tester
Catheter Flexibility Tester Compliance Standards YY/T 1554 - 2017. etc. ISO 10555 -Intravascular catheters- Sterile and single-use catheters ISO 11o70- Catheter introducers...
SDC Fading Grey Scale
SDC Fading Grey Scale Applicable Standards The SDC Grey Scale adheres to international colorfastness testing protocols, including: ISO 105-A02(Grey Scale for Asses...
Safety shoe impact testing machine / Safety shoes testing machine
Safety shoe impact testing machine / Safety shoes testing machine According to the criteria: Bs-953.1870 EN-344. ANSI-Z41 CSA-Z195 ISO K88782 EN ISO 20344. ANSI-Z41 BS EN-344 CSA-ZI95 Product Advantages:...
供应产品

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution 卖方: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors 卖方: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber 卖方: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester 卖方: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors 卖方: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...