Sand and Dust Test Chamber for Automotive Connectors

Operating Conditions:

Ambient temperature: 5°C~+28°C (average temperature within 24 hours ≤28°C); Ambient humidity: ≤85%

Technical Parameters:

1. Nominal spacing of the metal mesh is 50μm, and the nominal spacing between wires is 70μm

2. Airflow velocity: ≤2m/s (standard type) or ≥2m/s (specify when placing an order) 3. Continuous or periodic dust - blowing can be freely selected, or time can be set 4. Talcum powder dosage: 2kg - 4kg/㎡ 5. Dust for testing: Dry talcum powder, portland cement, soot, etc. 6. Vibration time: adjustable from 0 to 9999 minutes (M represents minutes) 7. Fan cycle time: 0 to 9999 minutes (M represents minutes) 8. Standard configuration: The sand and dust testing equipment is equipped with 2 specimen racks and 2kg of talcum powder 9. Power requirements: AC380(±10%)V/50HZ, three - phase five - wire

Product Applications:

This equipment is suitable for dust - proof and dust - resistance tests of various automotive components, including vehicle lamps, instruments, electrical dust - proof sleeves, steering systems, door locks, etc., to verify the sealing quality of products.

Structural Features:

1. Material of the chamber outer shell: High - quality carbon steel plate, with phosphating and electrostatic powder spraying on the surface, and hairline treatment for SUS304 stainless - steel strips; 2. Inner liner material: Imported SUS stainless - steel polished plate; 3. Chamber door: Tempered glass door, facilitating the observation of the tested samples inside the test chamber; 4. High - quality fixed PU casters are used at the bottom; 5. There is a dust - replacement device at the bottom of the test chamber

System Structure:

1. Control system: The sand and dust testing equipment is controlled by a programmable logic PLC controller to manage the time and sequence of the dust - blowing, vibration and vacuum systems

2. Actuating components: "Schneider" AC contactors, switches, buttons; "Fuji" intermediate relays; "Panasonic" dust - proof sockets

3. Dust pre - heating system: Stainless - steel mica heating jacket, with stable and safe heat; it has timer - controlled heating; Vacuum system: Equipped with a pressure gauge, air filter, pressure - regulating triple unit and connecting pipes (the vacuum pump is provided separately, please specify when placing an order)

4. Power socket for test specimens: Dust - proof socket, AC220V 16A

5. Circulating fan: Low - noise motor with a multi - blade centrifugal impeller

6. Protection system: With protection functions against electric leakage, short - circuit, over - temperature, motor overheating, over - current / power - off memory protection for the controller


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Electronic single fiber strength meter
Electronic single fiber strength meter Compliance Standards - GB/T14337 - GB/T9997 - GB/T13835.5 - GB/T21120 - ISO5079 - ISO11566 - ASTM D3822 - BS4029 Application Scope - Used...
Multi-Finger Scratch/Mar Tester
Multi-Finger Scratch/Mar Tester Standards Chrysler LP-463DD-18-01 Scratch and Mar Resistance of Automotive Plastics Chrysler PF-10938 Scratch and Mar - Resistance of Molded-In-C...
Hexapod Tumbler test machine-QINSUN
Hexapod Tumbler test machine-QINSUN Standard BSEN 1471:1997: Evaluation of Appearance Changes in Floor Coverings ISO 9405:2001: Floor Coverings – Determination of Appearance C...
Parts Valves Tube Cleaning
Parts Valves Tube Cleaning A robot system to clean parts, valves and tubes. By high pressure water tools together the intelligent programming, the system can make the clean ...
Fabric Hand Feel Tester
Fabric Hand Feel Tester Brief Introduction:By softness value of the test material and objective evaluation of its feeling (touch) performance for softness test fabrics, te...
供应产品

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution 卖方: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors 卖方: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber 卖方: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester 卖方: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors 卖方: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...