Sand and Dust Test Chamber for Automotive Connectors

Operating Conditions:

Ambient temperature: 5°C~+28°C (average temperature within 24 hours ≤28°C); Ambient humidity: ≤85%

Technical Parameters:

1. Nominal spacing of the metal mesh is 50μm, and the nominal spacing between wires is 70μm

2. Airflow velocity: ≤2m/s (standard type) or ≥2m/s (specify when placing an order) 3. Continuous or periodic dust - blowing can be freely selected, or time can be set 4. Talcum powder dosage: 2kg - 4kg/㎡ 5. Dust for testing: Dry talcum powder, portland cement, soot, etc. 6. Vibration time: adjustable from 0 to 9999 minutes (M represents minutes) 7. Fan cycle time: 0 to 9999 minutes (M represents minutes) 8. Standard configuration: The sand and dust testing equipment is equipped with 2 specimen racks and 2kg of talcum powder 9. Power requirements: AC380(±10%)V/50HZ, three - phase five - wire

Product Applications:

This equipment is suitable for dust - proof and dust - resistance tests of various automotive components, including vehicle lamps, instruments, electrical dust - proof sleeves, steering systems, door locks, etc., to verify the sealing quality of products.

Structural Features:

1. Material of the chamber outer shell: High - quality carbon steel plate, with phosphating and electrostatic powder spraying on the surface, and hairline treatment for SUS304 stainless - steel strips; 2. Inner liner material: Imported SUS stainless - steel polished plate; 3. Chamber door: Tempered glass door, facilitating the observation of the tested samples inside the test chamber; 4. High - quality fixed PU casters are used at the bottom; 5. There is a dust - replacement device at the bottom of the test chamber

System Structure:

1. Control system: The sand and dust testing equipment is controlled by a programmable logic PLC controller to manage the time and sequence of the dust - blowing, vibration and vacuum systems

2. Actuating components: "Schneider" AC contactors, switches, buttons; "Fuji" intermediate relays; "Panasonic" dust - proof sockets

3. Dust pre - heating system: Stainless - steel mica heating jacket, with stable and safe heat; it has timer - controlled heating; Vacuum system: Equipped with a pressure gauge, air filter, pressure - regulating triple unit and connecting pipes (the vacuum pump is provided separately, please specify when placing an order)

4. Power socket for test specimens: Dust - proof socket, AC220V 16A

5. Circulating fan: Low - noise motor with a multi - blade centrifugal impeller

6. Protection system: With protection functions against electric leakage, short - circuit, over - temperature, motor overheating, over - current / power - off memory protection for the controller


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

CIP rotary spray head
CIP rotary spray head CIP rotary spray head/jet tank cleaning heads Model no.:STD75 Working Principle: Impeller is driven by cleaning fluid and drives internal reduct...
 Leakage trace tester
Leakage trace tester I. Product Overview TheLeakage Trace Testeris a precision diagnostic tool designed to visually identify and analyze fluid/gas leakage paths in sea...
Friction Tester for Non - woven Fabrics
Friction Tester for Non - woven Fabrics Instrument Description This fabric friction tester can measure the static and kinetic friction coefficients of non - woven fabrics. It can be used...
Textile Flatness Tester
Textile Flatness Tester Product Overview TheTextile Flatness Testeris a precision instrument designed to evaluate fabric surface evenness by quantifying thickness variati...
Textile Far - Infrared Radiation Heating Tester
Textile Far - Infrared Radiation Heating Tester Application ScopeThis instrument is used to determine the far-infrared properties of various textile products, including fibers, yarns, fabrics, no...
供应产品

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution 卖方: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors 卖方: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber 卖方: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester 卖方: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors 卖方: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...