.

AC/DC Current - Carrying Temperature - Rise and Voltage - Drop Test System for Automotive Wires

Application Scope:

1. Record the temperature change of conductors in connectors under a certain current.

2. Record the magnitude of the current passing through conductors in connectors at the set conductor temperature.

3. Record the changes in voltage drop.

4. Have a cyclic testing function.

Test Standards:

Test requirements such as JASO D609: 2001. QC/T29106. QC/T 1067.1. QC/T417.1. TICW15. etc.

Main Parameters:

ParameterDescription
Input voltage AC380V ±10%, 50Hz
Types of load power supplies DC: Switching power supply; AC: AC constant-current source
Operating current AC: 1000A, Open-circuit voltage: Maximum 10V; DC: 10–1000A, Open-circuit voltage: Maximum output 10V
Current output mode Set via computer
Ammeter accuracy ±1% + 3 digits
DC voltage drop ranges Range 1: 0.01mV – 199.99mV; Range 2: 0.1mV – 1999.9mV
Timing range 0 – 9999.99H/M/S (Automatic current cutoff upon timer completion)
Temperature meters Standard 8-channel test thermometers; real-time display/record of T1C, T2C, T3C, T1S, and ambient temperatures (Thermocouple type: T-type 30AWG)
Thermal control Temperature regulation and monitoring for constant-temperature chamber

在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Computer-controlled Explosion-proof Capillary Rheometer
Computer-controlled Explosion-proof Capillary Rheometer Standards HG/T 4300-2012 ISO 11443 Scope of application 1. It is suitable for measuring the shear rate of plastics and polymer materials and th...
Geosynthetics Horizontal Penetration Tester
Geosynthetics Horizontal Penetration Tester Scope of application: Used to determine the horizontal permeability of geosynthetics under constant head flow conditions. Under the conditions of ...
Automotive Comfort Air Conditioning Dummy Test System
Automotive Comfort Air Conditioning Dummy Test System Applicable standards: ISO related standards, such asISO 14505-2. which provide test methods and evaluation indicators for thermal comfort. Berkel...
Wire Bending Test Machine
Wire Bending Test Machine Product Introduction: Wire bending tester meets JIS-C-3005 test standard. The sample is inserted through the specified round hole according to thi...
Limiting Oxygen Index Tester
Limiting Oxygen Index Tester Limiting Oxygen Index Tester The oxygen index of the material refers to the minimum oxygen concentration that can maintain the combustion of the ma...
供应产品

Same products

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution 卖方: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors 卖方: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber 卖方: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester 卖方: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors 卖方: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...