Floor Material Burning Performance Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
ASTM E648-15 Standard test method for critical radiant flux of floor-covering systems using radiant heat energy source
BS EN ISO Reaction to fire test for flooring-Part 1: Determination of the burning behavior using a radiant heat source
GB/T 11785-2005 Determination of Combustion Performance -Floor material radiation heat source method
ISO 9239-1: Flooring fire reaction test- Part 1: Combustion performance of flooring materials tested by radiant heat
ASTM E 648: Critical Radiant Flux of Floor standard test - covering system uses radiant heat energy
ASTM E 970: Using a Radiant Heat Energy Source, test insulation floorinsulation insulation standard test for Critical Radiant Flux using a radiant heat energy.
NFPA 253: Standard Test Method for using radiant heat energy, test plates overlay system Critical Radiant Flux
Technical Parameters
| Parameter | Specification |
|---|---|
| Maximum power | 5 kW |
| Timing accuracy | <1 s/h |
| Heat flux sensor range | 0–15 kW/m² |
| Heat flux sensor accuracy | ±0.2 kW/m² |
| Heat flux sensor precision | <±3% |
| Radiant high-temperature sensor range | 400–600°C, ±0.5°C |
| Black body temperature error | ±5°C |
| Exhaust air velocity | (2.5 ± 0.2) m/s |
| Exhaust capacity | 39–85 m³/min |
| Porous refractory radiation panel size | 300 × 450 mm, withstands ~900°C |
| Thermocouple specification | Ø3.2 mm, K-type stainless steel armored |
| Burner specification | Outer Ø10 mm, inner Ø6 mm, nozzle Ø0.7 mm |
| Flame height adjustment | 60–120 mm, adjustable |
| Ignition system | High-voltage electronic ignition |
| Exhaust system | Forced ventilation, fumes discharged outdoors |
Accessories
| Accessory | Quantity | Description |
|---|---|---|
| 304 stainless steel flame height gauge | 1 | Measures flame height |
| Gas pipe clamps | 2 | Secures gas tubes |
| User manual | 1 | Instructions for operation and maintenance |
| Certificate of conformity | 1 | Confirms product quality inspection |
Features
The main components are imported, which is safe and reliable, long service life;
Gas pipeline layout is reasonable, equipped with gas leakage and tempering device. The instrument automatically closes at the inlet of gas leakage, and alarm;
Radiant plate temperature can be automatically adjusted.
Propane gas supply is equipped with imported mass flow controller. The air output is equipped with a separate blower. Automatic adjustment of the frequency without manual;
Normal test, the flame spread distance can be recorded through the foot switch, without the need to manually click the mouse to operate the computer;
Instrument with industrial one machine, is easy to operate and reliable;
The instrument adopts advanced control software developed by VB language. Centralized control acquisition and processing data analysis;
在线联系供应商
Other supplier products
| Constant Strain Geomembrane Crack Resistance Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com In the field of materials science and engineering, environmental stress cracking testing ma... | |
| Walk in pharmaceutical stability chamber for drug testing | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Pharmaceutical Stability Testing Laboratory is a high-precision environme... | |
| Abrasive Wear Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM G65 - 04 GB/T 3960-1983 Main Purposes The wet - type rubber wheel abrasiv... | |
| Laminoplasty Plate System Fatigue Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F2193-18: Specifies static/fatigue testing protocols for spinal constructs, ... | |
| Anti-siphon machine for shoelace manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications (1)Testing waterproof leather and synthetic leather used in sho... |