Automatic pneumatic foam fatigue testing equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The HD2 Pneumatic Foam Fatigue Tester complies with or references the following standards:
ASTM D3574 – Flexible Cellular Materials, Dynamic Fatigue Testing (Constant Force Method)
ISO 3385 – Polymeric materials, flexible cellular — Determination of fatigue by constant-load pounding
GB/T 10807 – Flexible cellular polymeric materials — Determination of compression properties (dynamic reference)
GB/T 6342 – Cellular plastics and rubber — Determination of linear dimensions (specimen preparation reference)
Parameters
| Parameter | Unit | Specification |
|---|---|---|
| Test Station | — | Single station |
| Loading Mode | — | Constant load (standard), constant displacement (optional) |
| Test Frequency | cycles/min | 70 |
| Load Measurement Range | lbf | 500 – 2500 |
| Indenter Type | — | Square indenter (multiple sizes available) |
| Standard Indenter Size | in | 15 × 15 (ASTM compliant) |
| Maximum Specimen Height | in | 15 |
| Maximum Specimen Width | in | 28 |
| Maximum Specimen Depth | in | 24 |
| Drive Method | — | Pneumatic (compressed air) |
| Control System | — | PLC with touchscreen interface |
| Power Supply | — | AC 120 V / 240 V |
| Equipment Dimensions | mm | 1070 × 1015 × 870 |
| Equipment Weight | kg | Approx. 69 |
| Construction Material | — | Anodized aluminum and stainless steel |
Features
Pneumatic loading system provides fast response and stable cyclic force
Supports both constant load and optional constant displacement fatigue modes
High-capacity load cell ensures reliable force monitoring during long-duration tests
Standard vented grid and indenter design compliant with international foam fatigue standards
Touchscreen human–machine interface for intuitive parameter setting and operation
Reinforced test platform accommodates large foam specimens
Compatible with standard foam samples and localized fatigue testing on mattresses
Accessories
Standard square indenters (multiple sizes available)
ASTM-compliant vented support grid
High-range load cell
Specimen positioning and fixing components
Pneumatic quick-connect fittings
Integrated control and monitoring software
Test Procedures
Prepare foam specimens in accordance with the applicable standard
Level the equipment and connect electrical power and compressed air supply
Install the vented grid and selected indenter
Position and secure the foam specimen on the test platform
Set loading mode, test frequency, and cycle count via the touchscreen
Start the test and allow the system to run automatically
Stop the machine automatically upon completion of the programmed cycles
Remove the specimen and proceed with post-test evaluation
在线联系供应商
Other supplier products
| Safety shoe impact tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com According to the criteria Bs-953.1870 EN-344. ANSI-Z41 CSA-Z195 ISO K88782 EN ISO 203... | |
| Syringe needle flow tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Syringe Needle Flow Tester is designed to evaluate the flow characteristics of syringes... | |
| Thermal Radiation Flame Spread Tester,ASTM E1354 Thermal Radiation Flame Propagation Test Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Thermal Radiation Flame Spread Tester is designed to evaluate the combustion characteri... | |
| Adiabatic Accelerated Calorimeter,adiabatic calorimeter apparatus bulk order | Whats/App: +86 156 1874 6768 Web: standard-groups.com An Accelerating Rate Calorimeter (ARC) is a high-precision thermal analysis instrument that... | |
| Absorbable Bone - connecting Plates Four - point Bending Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Absorbable Bone-connecting Plates Four-point Bending Tester is a specialized testing ma... |













