Y5WZ-17-45 AC Gapless MOA

AC gapless metal oxide arrester (hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.

indoor AC gapless metal oxide arrester(hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.

Product Implementation Standard: GB11032 - 2010 "AC Gapless Metal Oxide Arrester".

This kind of arrester is assembled by superposition of non-linear zinc oxide resistors and sealed in high voltage insulating ceramic sleeve without any discharge gap.Under normal operating voltage, the arrester is insulated with high resistance; when it is impacted by overvoltage, the arrester is in low resistance state, releasing impulse current into the ground quickly, so that the voltage on the electrical equipment parallel to it is limited to the prescribed value, so as to ensure the safe operation of the electrical equipment.The arrester is equipped with a detachment device. When the arrester operates under overload or suffers accidental damage, the internal pressure increases sharply, so that the arrester can be detached from the device to ensure that the ceramic sleeve is not damaged.The arrester has the characteristics of good steep wave response, high shock current tolerance, low residual voltage, reliable operation, no power frequency continuous current, simple maintenance and so on.

  1. arrester should be prevented before it is put into operation and before the thunderstorm season every year.

Sex testing tests, the items are:

(1) DC or power frequency reference voltage test:

When the peak value of DC or AC resistive current flowing through the arrester reaches the reference current, read the voltage value, which is not less than the standard value.

(2) DC leakage current test:

The DC voltage value of 0.75U1mA is applied at both ends of the arrester (the voltage ripple rate is not more than (+1.5%). When the voltage is stabilized, the leakage current flowing through the arrester should not be greater than the standard value. The leakage current of the surge arrester in operation should be no more than 2 times of the measured value before commissioning.

(3) Detection of power frequency persistent current value:

Power Frequency Continuous Current Value, Leakage Current Tester or Sufficient for Use of Arresters

Accurate AC meter detection shows that the RMS or peak resistance current flowing through the arrester under operating power frequency voltage does not exceed 1.5 times of the initial measurement value.

Ⅵ. Attention:

(1) During transportation and storage, arresters should be placed vertically.

(2) Users are not allowed to disassemble lightning arresters at will.

(3) Users are not allowed to test the working frequency discharge voltage of the arrester in order to avoid damage to the arrester.

(4) Under the condition that users abide by the above rules, our factory is responsible for the three-package matters within the three-package period, which is one year.

If users have special needs, they can write to them. We will supply as required.

If you have any question on Industrial frequency converter cabinet, plc control cabinet. We will give the professional answers to your short questions. If you need, welcome to contact us to know more!



Send product request

To: Wisdom Automatic Equipment (Wuxi) Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

WSD-YBW series Prefabricated Substation
WSD-YBW series Prefabricated Substation WSD-YBW series Prefabricated Substation Overview WSD-YBW series Prefabricated Substation is a series of products designed and developed by our comp...
JP outdoor integrated distribution box
JP outdoor integrated distribution box JP outdoor integrated distribution box Summary WSD-JP outdoor integrated distribution device is a kind of outdoor integrated distribution devi...
XL-21 low-voltage power distribution cabinet
XL-21 low-voltage power distribution cabinet XL-21 low-voltage power distribution cabinet Overview XL-21 Low Voltage Switch Cabinet is suitable for power plant, industry and mining enterp...
AC gapless metal oxide arrester
AC gapless metal oxide arrester AC gapless metal oxide arrester AC gapless metal oxide arrester (hereinafter referred to as arrester) is used to protect AC electrical equipment of...
WSD-ZW32-24GD Outdoor AC high voltage vacuum circuit breaker
WSD-ZW32-24GD Outdoor AC high voltage vacuum circuit breaker WSD-ZW32-24GD Outdoor AC high voltage vacuum circuit breaker Overview WSD-ZW32-24GD Outdoor AC high voltage vacuum circuit breaker (...
All supplier products

Same products

Category 6A/6 F/UTP Patch/Lan cable
Category 6A/6 F/UTP Patch/Lan cable Seller: Dongguan AIKE Electronics co., LTD. Category 6A/6 F/UTP Patch/Lan cable USB Cable Assembly Factory Cable Assembly Factory Main functi...
Type C 3.1 Gen2, 24PIN, right angle, Contacts with DIP and SMT type
Type C 3.1 Gen2, 24PIN, right angle, Contacts with DIP and SMT type Seller: Dongguan AIKE Electronics co., LTD. Type C 3.1 Gen2, 24PIN, right angle, Contacts with DIP and SMT type Connectors Type c Type c Conn...
Principle of isolating transformer
Principle of isolating transformer Seller: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd. Principle of isolating transformer Principle of isolating transformer The principle of three...
How to calculate the calorific value of transformer?
How to calculate the calorific value of transformer? Seller: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd. How to calculate the calorific value of transformer? The calorific base of transformer = no load ...
What are the steps of transformer maintenance?
What are the steps of transformer maintenance? Seller: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd. What are the steps of transformer maintenance? Transformer is an important electrical equipment t...