Light Curtain Safety Relay
ChenzhuLight curtain Safety Relay supports PNP-type light beam devices. Safety relay modules provide a high level of fail-safe operation for critical processes and protection. These light curtains and multifunction controllers provide multiple functions such as release delay, muting, stepping, and protection for multiple curtains.
Automation safetyrated relays can choose single or dual channel operation, manual or automatic reset, with function of short circuit monitoring between channels.
Features & Advantages of Light Curtain Safety Relay
Support PNP type light beam device
Support dual channel
Support manual or automatic reset
Parameter of Light Curtain Safety Relay
|
CZSR8001-3A1B-P |
CZSR8101-3A1B-N |
|
|
Supply voltage |
24V DC |
24V DC |
|
Voltage tolerance |
||
|
Current consumption |
≤90mA (24V DC) |
≤90mA (24V DC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
|
Input devices |
PNP type light beam devices |
NPN type light beam devices |
|
Number of contacts |
3NO+1NC |
3NO+1NC |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2+ 0.2 µm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO) ;6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
|
Utilization category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
|
Recovery time |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
|
Pollution degree |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
|
Category |
Block Diagram of Light Curtain Safety Relay
Typical Applications of Light Curtain Safety Relay.
Send product request
Other supplier products
| Safety Mat Safety Relay | Safety Mat Safety Relay Automation safetyrelay modules provide a high level of fail-safe operation for critical processes and protection. This saf... | |
| AC Power SPD | The power surge protector for power surge ac unitis designed to prevent transient surge conditions. Large single surge events, such as lightning, c... | |
| Temperature Transmitter | CHENZHU, a reliable temperature transmitter manufacturers, provides a large range of head-mounted temperature transmitters at an affordable price. ... | |
| Temperature Transmitter | CHENZHU, a reliable intrinsically safe temperature sensorand temperature transmitter manufacturer, provides a large range of head-mounted temperatu... | |
| Intrinsic Safety RTD TC Temperature Transmitter | Isolated intrinsically safe temperature transmitter, deliver the field thermocouple(TC) or thermal resistance(RTD) signal by digital linearization,... |