Rubber Mechanical Properties Tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The Rubber Sleeve Rebound Tester is designed to comply with the following standards:

(1) YY/T 1618-2018: Collection Needle Rubber Sleeve Resilience Test (China)

(2) DIN 53 512: Testing of Rubber – Rebound Resilience (Germany)

(3) ISO 4662: Rubber, Vulcanized or Thermoplastic – Determination of Rebound Resilience

(4) ASTM D7121: Standard Test Method for Rubber Compression Set

Features

(1) Accurate measurement of rubber sleeve resilience at multiple distances.

(2) Adjustable test speed and pressure for various sample requirements.

(3) Real-time display of test force and calculated results.

(4) Onboard printing for test reports, including average values and deviation.

(5) Supports testing of needles and collection tubes with minimal setup.

(6) Compact design suitable for laboratory and production environments.

Parameters

ParameterSpecification
Pressure test range 0 – 50 N, error ≤ ±1%, resolution 0.01 N
Test time 1 – 999 s, error ≤ ±0.5 s
Test speed 50 mm/min, 80 mm/min, 100 mm/min, error ≤ ±2%
Measuring distance 0 – 50 mm, error ≤ ±0.1 mm
Rebound force range 0.5 – 1.5 N
Printing capability 8. 10. or 13 test data points, including average and deviation
Machine dimensions Customizable depending on model and fixture
Power supply AC220 V, 50 Hz (standard)

Accessories

(1) Main test unit – 1 set

(2) Needle clamping fixtures – 1 set

(3) Printer paper roll – 1 piece

(4) Operation manual – 1 set

(5) USB storage (optional)

Test Procedures

(1) Insert the needle at the butt end into the die hole of the clamping fixture, 2 mm above the surface.

(2) Start the test device to compress the rubber sleeve.

(3) Measure the rubber sleeve resilience at distances of 5 mm and 15 mm between the needle tube and the needle base.

(4) The instrument displays and records the rebound force. Each test can print 8. 10. or 13 data points, including average and deviation.

(5) Confirm that the measured resilience falls within the standard range of 0.5 N ≤ resilience ≤ 1.5 N.

Maintenance Information

(1) Regularly clean the clamping fixtures and die holes to prevent debris buildup.

(2) Calibrate the force sensor periodically to maintain accuracy.

(3) Avoid prolonged exposure to high humidity or corrosive environments.

(4) Inspect electrical connections and printer components for wear or damage.

(5) Follow standard laboratory safety procedures when operating the device.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Safety Helmets Wearing Stability Tester
Safety Helmets Wearing Stability Tester Standard GB 811-2022: Safety Helmets – General Technical Requirements GB 24429-2009: Sports Helmets – Requirements and Test Methods ...
Automated transient hot-wire thermal conductivity testing equipment
Automated transient hot-wire thermal conductivity testing equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Transient Hot-Wire Liquid Thermal Conductivity Analyzer is widely used in ...
Medical glove water-impermeability tester
Medical glove water-impermeability tester The medical glove water-impermeability tester is used to determine the water-impermeability performance of medical rubber examination gloves, inclu...
Shoelace eye wear testing machine丨Shoelace eye wear tester
Shoelace eye wear testing machine丨Shoelace eye wear tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Main uses: The shoelace eye wear testing machine is mainly used to test the wear resistanc...
Dry microbial penetration resistance tester
Dry microbial penetration resistance tester The Dry Microbial Penetration Resistance Tester assesses material resistance to dry bacteria-carrying particles (like human dandruff-sized). It tes...
All supplier products

Same products

Bending deformation suture needle instrument
Bending deformation suture needle instrument Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YY/T 0043 :Medical Suture Need...
Anchoring force guide pin device
Anchoring force guide pin device Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The device is designed to meet...
Bend strength catheter testing apparatus
Bend strength catheter testing apparatus Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed to ...
Advanced guide wire friction tester instrument
Advanced guide wire friction tester instrument Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed to ...
Automated needle flow tester for syringes
Automated needle flow tester for syringes Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed to ...