UV accelerated aging test equipment

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

This test chamber simulates the hazards caused by sunlight exposure and rain. It utilizes fluorescent UV lamps to mimic sunlight and distilled water spray to replicate rainfall effects. Test materials are subjected to cyclic light exposure at controlled temperatures. The chamber can replicate months or years of outdoor hazards within days or weeks. Typical damages include: fading, discoloration, gloss loss, chalking, cracking, hazing, blistering, embrittlement, strength degradation, and oxidation.

Standards

Standards Compliance:GB/T 14522-93(PRC National Standard:Accelerated Weathering Test Methods for Plastics, Coatings, and Rubber Materials in Mechanical Products)

Standard reference:ISO 4892. ASTM G151. G154. D4329. D4587. D4799. SAE J2020

Main parameters

UV Lamps: 8 units

Wavelength Range: UV-A (315~400nm)

Lamp Service Life: 1.500 hours

Temperature Range: RT+10℃~70℃

Temperature Resolution: 0.1℃

Temperature Uniformity: ±3℃

Temperature Control Mode: PID self-tuning control

Humidity Range: ≥75%RH

Distance Between Samples and Lamp Center: 25~45mm

Compliance Standards: GB/T 14522-93 (PRC National Standard:Accelerated Weathering Test Methods for Plastics, Coatings, and Rubber Materials in Mechanical Products)

Structure and Materials

Working Chamber Dimensions: 660×1150×600mm (Depth×Width×Height)

Overall Dimensions: Approx. 780×1380×1780mm

Inner Chamber Material: SUS304 stainless steel plate

Exterior Material: SUS304 stainless steel plate

UV Lamps: UVA-340 fluorescent UV lamps (8 units, 40W each)

Water Supply & Consumption: 8 liters/day of purified or distilled water (user-provided)

Control System: 7-inch touch screen, PLC programmable controller

Test Equipment

The chamber is constructed of corrosion-resistant metal materials, equipped with8 fluorescent UV lamps, sample racks, and temperature/time control systems with indicators.

Lamp Power: 40W per lamp.

Lamp Arrangement: Lamps are installed in a single row, with two groups of four lamps each controlled by separate switches.

Sample Installation: Test samples are fixed at a distance of 50mm from the nearest lamp surface.

Chamber Placement Requirements:

The chamber must be placed in a laboratory with an ambient temperature of 15~35℃, 300mm away from walls, and isolated from external heat sources.

Avoid strong airflow in the laboratory to prevent interference with light exposure and condensation conditions.

Test Conditions

Sample Placement: Test samples are mounted on sample racks.

Test Temperature: Adjustable between RT+10~70℃ during light exposure, with a temperature tolerance of ±3℃.

Light/Condensation Cycles: Options include 4H light + 4H condensation, 8H light + 4H condensation, or other custom cycles.

Lamp Replacement: Replace 1-2 lamps after the first 400–450 hours of use. Subsequent replacements follow a rotational schedule to compensate for lamp aging, ensuring a service life of 1.600–2.000 hours per lamp.

Sample and Performance Evaluation

Visual Assessment:

Primarily for coatings (gloss, color change, chalking, spotting, blistering, cracking, dimensional stability).

Plastics and rubbers may also be evaluated visually if required.

Quantitative measurements are recommended using instruments (e.g., gloss meter, colorimeter).

Mechanical and Other Properties:

Rubber: Tensile strength, elongation, hardness.

Plastics: Impact strength, elongation at break, tensile strength, flexural strength.

Additional tests may be specified as needed.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Camera test light box
Camera test light box Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 12233: Compliant with SFR (Spatial Frequency Response) testing for lens resol...
Plastic Friction and Wear Tester
Plastic Friction and Wear Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description: Plastic sliding friction wear tester consists of two main parts: the ...
ISO certified Mechanical load testing machine for photovoltaic modules
ISO certified Mechanical load testing machine for photovoltaic modules Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Mechanical Load Testing Machine is a precision instrument designed to eva...
Safety Helmets Wearing Stability Tester
Safety Helmets Wearing Stability Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Safety Helmets Wearing Stability Tester is designed to evaluate helmet retention and fi...
Fiber Oil Extractor
Fiber Oil Extractor Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fiber Oil Extractor, also known as the Rapid Grease Extraction Apparatus, is designed f...
All supplier products

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...