UV accelerated aging test equipment
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
This test chamber simulates the hazards caused by sunlight exposure and rain. It utilizes fluorescent UV lamps to mimic sunlight and distilled water spray to replicate rainfall effects. Test materials are subjected to cyclic light exposure at controlled temperatures. The chamber can replicate months or years of outdoor hazards within days or weeks. Typical damages include: fading, discoloration, gloss loss, chalking, cracking, hazing, blistering, embrittlement, strength degradation, and oxidation.
Standards
Standards Compliance:GB/T 14522-93(PRC National Standard:Accelerated Weathering Test Methods for Plastics, Coatings, and Rubber Materials in Mechanical Products)
Standard reference:ISO 4892. ASTM G151. G154. D4329. D4587. D4799. SAE J2020
Main parameters
UV Lamps: 8 units
Wavelength Range: UV-A (315~400nm)
Lamp Service Life: 1.500 hours
Temperature Range: RT+10℃~70℃
Temperature Resolution: 0.1℃
Temperature Uniformity: ±3℃
Temperature Control Mode: PID self-tuning control
Humidity Range: ≥75%RH
Distance Between Samples and Lamp Center: 25~45mm
Compliance Standards: GB/T 14522-93 (PRC National Standard:Accelerated Weathering Test Methods for Plastics, Coatings, and Rubber Materials in Mechanical Products)
Structure and Materials
Working Chamber Dimensions: 660×1150×600mm (Depth×Width×Height)
Overall Dimensions: Approx. 780×1380×1780mm
Inner Chamber Material: SUS304 stainless steel plate
Exterior Material: SUS304 stainless steel plate
UV Lamps: UVA-340 fluorescent UV lamps (8 units, 40W each)
Water Supply & Consumption: 8 liters/day of purified or distilled water (user-provided)
Control System: 7-inch touch screen, PLC programmable controller
Test Equipment
The chamber is constructed of corrosion-resistant metal materials, equipped with8 fluorescent UV lamps, sample racks, and temperature/time control systems with indicators.
Lamp Power: 40W per lamp.
Lamp Arrangement: Lamps are installed in a single row, with two groups of four lamps each controlled by separate switches.
Sample Installation: Test samples are fixed at a distance of 50mm from the nearest lamp surface.
Chamber Placement Requirements:
The chamber must be placed in a laboratory with an ambient temperature of 15~35℃, 300mm away from walls, and isolated from external heat sources.
Avoid strong airflow in the laboratory to prevent interference with light exposure and condensation conditions.
Test Conditions
Sample Placement: Test samples are mounted on sample racks.
Test Temperature: Adjustable between RT+10~70℃ during light exposure, with a temperature tolerance of ±3℃.
Light/Condensation Cycles: Options include 4H light + 4H condensation, 8H light + 4H condensation, or other custom cycles.
Lamp Replacement: Replace 1-2 lamps after the first 400–450 hours of use. Subsequent replacements follow a rotational schedule to compensate for lamp aging, ensuring a service life of 1.600–2.000 hours per lamp.
Sample and Performance Evaluation
Visual Assessment:
Primarily for coatings (gloss, color change, chalking, spotting, blistering, cracking, dimensional stability).
Plastics and rubbers may also be evaluated visually if required.
Quantitative measurements are recommended using instruments (e.g., gloss meter, colorimeter).
Mechanical and Other Properties:
Rubber: Tensile strength, elongation, hardness.
Plastics: Impact strength, elongation at break, tensile strength, flexural strength.
Additional tests may be specified as needed.
Send product request
Other supplier products
| Camera test light box | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 12233: Compliant with SFR (Spatial Frequency Response) testing for lens resol... | |
| Plastic Friction and Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description: Plastic sliding friction wear tester consists of two main parts: the ... | |
| ISO certified Mechanical load testing machine for photovoltaic modules | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Mechanical Load Testing Machine is a precision instrument designed to eva... | |
| Safety Helmets Wearing Stability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Safety Helmets Wearing Stability Tester is designed to evaluate helmet retention and fi... | |
| Fiber Oil Extractor | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fiber Oil Extractor, also known as the Rapid Grease Extraction Apparatus, is designed f... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |