Building Material Flammability Test Furnace, ISO 11925-2 Flammability Tester
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Stainless steel plate box | 1.5mm |
| Bunsen burner | can be adjusted forward and backward |
| Diameter of burner | Φ 0.17mm burner with regulator; four ¢4mm air suction inlet |
| Flame length of Bunsen burner | 20mm ± 2mm |
| Ignition source | can be automatically tilted by 45 degrees |
| The Bunsen burner applies a flame time | 15s to the pattern |
| Flame height | Adjusted by precision adjustment valve |
| Sample rack | can move up and down and back and forth |
| Sample holders | 2 pcs |
| Touch screen display | 7 inches Effective display size 15.5cm in length and 8.6cm in width |
| Resolution | 800 * 480 |
| Communication interface | RS232. 3.3V CMOS or TTL, serial port mode |
| Storage capacity | 1G |
| FPGA driver display | "zero" start time, can run after power on |
| Controller | adopts low energy consumption processor, and automatically enters energy saving mode |
| Gas source | >95% propane gas;(user should provide for themselves) |
| Gas pressure | 10kpa~50kpa |
| Flue air velocity | 0.7m/s only on condition of burner burning and draught hood open |
| Time adjustment of continuous flame | 0 ~ 99minutes99seconds |
| Time adjustment of afterflame | 0 ~ 99minutes99seconds |
| Timer accuracy | ≤1s/h |
| Ambient temperature | 15 ℃ ~ 25 ℃; |
| Relative humidity | ≤ 85% |
| Cabinet size | 835 × 400 × 815mm |
| Power supply voltage and power | 220 V, 50 Hz, 100 W |
Accessoriess
1. Building Material Flammability Tester 1 unit
2. Power cord 1 piece
3. Gas pipe (with clamp) 1 piece
4. Clamps 2 sets
5. Flame height measuring device 1 unit
6. Flame positioner 2 units
7. Stainless steel wind speed device (optional) 1 set
8. Product manual 1 copy
9. Product certificate of conformity 1 piece
Test Procedures
I. Equipment Installation and Preparation
Accessory Check: Confirm that the included accessories include the sample holder, positioning device, drip tray, flame ruler, gas valve, and gas pipe. If a wind speed device is selected, an additional power supply needs to be connected, and the wind speed should be adjusted to 0.7 ± 0.1 m/s.
Gas and Power Connection: Install the valve onto the gas cylinder (the safety valve needs to be opened manually), and connect the equipment's power and gas supply. If a wind speed meter is equipped, calibrate the airflow direction and insert it into the temperature measurement port.
II. Operating Procedure
Parameter Settings: Set the experiment time (usually 15 seconds or 30 seconds) via the touchscreen interface, and select whether to enable the "automatic ignition" or "automatic gas shut-off at the end of the experiment" function.
Sample Installation: Use the sample holder to fix the material (usually 250mm × 90mm), and adjust the flame contact position using the positioning device (e.g., 40mm from the bottom edge).
Flame Adjustment: Start the gas and ignite the flame, adjust the Bunsen burner to a 20 ± 2mm blue flame, and tilt it 45 degrees towards the sample.
III. Experiment Execution and Observation
Start Experiment: After clicking "Start," the burner contacts the sample and the countdown begins. Observe the combustion phenomena (e.g., surface ignition, burning to the marked line).
Data Recording: Save the data after the experiment, turn off the gas, and check the sample's combustion status (e.g., remaining length, whether dripping material ignites the filter paper).
IV. Safety and Maintenance
Operating Procedures: Avoid putting hands into the test furnace, and do not stack flammable materials around the equipment. Stop the machine immediately in case of any abnormalities.
Regular Calibration: Calibrate the heat load uniformity (4-point temperature difference ≤ 15℃) and wind speed (5-point measurement error ≤ 10%) every 3 months.
Send product request
Other supplier products
| Drying Rate Tester Heated Plate Method ISO Standard Manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards AATCC 201-2013 Fabric Drying Rate: Hot Plate Method FZ/T 01176-20... | |
| Medical injection needle rigidity tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Medical Injection Needle Rigidity Tester is designed to evaluate the mechanical rigidit... | |
| Pipe coating scratch tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Paint and varnish scratch resistance tester, also known as scratch r... | |
| Automatic Scratch Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automatic Scratch Tester is designed for evaluating the hardness and friction performan... | |
| ASTM Standard Taber Abrasion Test Machine Dual Head Type | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Taber Abrasion Tester (Double-Head) is used for abrasion and wear resistance ... |