ISO 11155 Filter Test System
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system complies with:
(1) ISO 11155-1 – Test method for particulate filtration performance of fuel cell air filters.
(2) ISO 11155-2 – Test method for adsorption performance of fuel cell air filters.
(3) DIN 71460-1 – German standard for particulate filtration of fuel cell air filters.
(4) DIN 71460-2 – German standard for adsorption performance testing of fuel cell air filters.
Parameters
| Parameter | Unit | Value |
|---|---|---|
| Test Flow Rate | m³/h | 70 … 1400 |
| Differential Pressure Measuring Range | Pa | ≤1000 |
| Test Specimen Dimensions | mm | ≤500 × 700 (bypass option: 100 cm²) |
| Operating Medium (Aerosol) | – | ISO 12103-1 A2 fine test dust, DEHS, NaCl, KCl |
| Operating Medium (Gas) | – | Nitrogen dioxide, Hydrogen (others on request) |
| Operating Medium (Standard/ Pollutant Gas) | – | n-Butane (80 ppm), Toluene (80 ppm), Sulphur dioxide (30 ppm) |
| Operating Medium (Other Gas) | – | Nitrogen dioxide (30 ppm), Ammonia (30 ppm), Hydrogen sulphide (0.4 ppm), Acetaldehyde (30 ppm) |
| Power Supply | – | 3 × 400 VAC; 32 A; 50 Hz |
| Gas Sensors | – | FID (organic substances), UV-fluorescence (SO₂), CLD (NOx) |
| Other Sensors | – | Temperature, Relative Humidity, Barometric Pressure |
| System Dimensions | mm | 5000 × 2750 × 3400 |
Features
Gas-tight Test Channels: Ensure no leakage during aerosol or gas testing.
Modular Structure: Adaptable to different filter sizes and test requirements.
High Degree of Automation: Software-based test sequences minimize manual intervention.
Standardized Reporting: Automatic generation of test reports for efficiency and adsorption results.
Versatile Testing Mediums: Support for aerosols (salt, oil, dust) and gases (NO₂, H₂, n-butane, toluene, SO₂, NH₃).
Accessories
(1) Filter adapters – enable secure mounting of different filter types.
(2) Aerosol generators – for fine dust, DEHS, NaCl, KCl.
(3) Gas dosing units – for standard and pollutant gases including NO₂, H₂, n-butane, SO₂.
(4) Gas sensors – FID, UV-fluorescence, CLD for real-time detection.
Test Procedures
Preparation:
Select the filter type and confirm its dimensions fit the test duct.
Set up the appropriate aerosol or gas medium according to the test standard.
Testing:
Insert the test filter into the filter adapter and mount it in the test duct.
Define test flow rate and start the automated sequence.
The system measures differential pressure, dust loading, fractional efficiency, and adsorption/desorption curves.
Data Analysis:
Collect data via software and analyze filter performance.
Generate standardized reports for quality assurance or R&D documentation.
Maintenance Information
Ensure all gas and aerosol lines are properly sealed to prevent leaks.
Periodically calibrate sensors and aerosol generators to maintain measurement accuracy.
Keep the system clean and check mechanical components for wear.
Ensure ventilation and follow safety guidelines when working with gases.
Send product request
Other supplier products
| Surgical Blade Sharpness Tester | The Surgical Blade Sharpness Tester is a multi-functional testing device featuring a 7-inch LCD touchscreen display, suitable for testing the sharp... | |
| Combustion Test Manikin | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Burning Manikin System is primarily applied in the following areas: Fire ... | |
| Femoral Stem Fatigue Performance Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0809.4 (China): Specifies fatigue testing protocols for femoral stems in par... | |
| Pipe Coating Scratch Resistance Tester (for Pipe coating scratch tester) | Product Introduction: Paint and varnish scratch resistance tester, also known as scratch resistance tester or balanced scratch rod adhesion resist... | |
| ASTM needle flame tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The needle flame tester is widely used in various fields, including but not li... |
Same products
| ISO 29463 HEPA/ULPA filter performance testing System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| ISO 12103 Cleanable Filter Media Test System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Advanced Vehicle and Aircraft Air Intake Filter Test System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| EN 779 Turbine Filter Test System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... |