Medical Face Mask Air Exchange Pressure Difference Tester
Products meet the standard requirements, which is YY0469-2004 "Medical surgical mask technical requirements" and YY 0969-2013 "Disposable medical masks", medical face mask air exchange pressure difference tester is measured by gas pressure difference on both sides of the mask (ie the damping from the mask exert to the airflow) to determine the breathability of the mask, and the instrument test results is accurate.
The device is used for the determination of gas exchange pressure difference of medical surgical masks and can also be used to determine the gas exchange pressure difference of other textile materials。
YY 0469-2011Surgical mask
YY 0969-2013Single-use medical face mask
EN 14683:2014Medical face masks - Requirements and test methods
YY 0969-2013Single-use medical face mask
EN 14683:2014Medical face masks - Requirements and test methods
1, using the suction gas source as the instrument power source, free from test space constraint;
2, with a high precision differential pressure sensor, digital show the sample pressure of both sides;
3, special sample holder to ensure a good clamping sample.
2, with a high precision differential pressure sensor, digital show the sample pressure of both sides;
3, special sample holder to ensure a good clamping sample.
Technical Parameters
| Items | Parameters |
| Air supply | Suction type |
| Air flow | 8L / min |
| Seal type | O-ring seal |
| Sample breathable diameter | Φ25mm |
| Differential pressure sensor range | 0 ~ 500Pa |
| Display mode | Digital display pressure difference |
| Power supply | 220V, 50Hz |
Send product request
Other supplier products
| Wool Fiber Fineness Analysis Tester | Wool fiber fineness value is measured by the airflow method. When exerting a certain pressure air to a certain amount of mass and volume of sample ... | |
| Textile Grease Extraction Apparatus | Rapid Grease Extraction Apparatus Testing Standards ofRapid Grease Extraction Apparatus: Edana method ERT 155 Applications: Rapid Grease Extraction... | |
| Anti Synthetic blood penetration tester | Standards: ASTM F1670; ASTM F1671; ASTM F903; ISO 16603; ISO 16604; GB 19082; YY/T 0689; YY/T 0700; Applications: It is applicable to the ... | |
| Flammability Tester for Construction Materials | Flammability Tester for Construction Materials is used to detect a variety of building materials and combustion performance measurement and control... | |
| Textile Grease Extraction Apparatus | Rapid Grease Extraction Apparatus Testing Standards ofRapid Grease Extraction Apparatus:Edana method ERT 155 Applications: Rapid Grease Extracti... |
Same products
| Air Permeability Tester STD- F8 | Seller: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | Seller: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | Seller: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | Seller: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | Seller: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |